chore: update docs/dyn (#1162)

This PR was generated using Autosynth. :rainbow:

Synth log will be available here:
https://source.cloud.google.com/results/invocations/b5e48daa-1759-436b-9fe7-ffce1482b520/targets

- [ ] To automatically regenerate this PR, check this box.
diff --git a/docs/dyn/displayvideo_v1.advertisers.manualTriggers.html b/docs/dyn/displayvideo_v1.advertisers.manualTriggers.html
index cd36f20..4f6d8b9 100644
--- a/docs/dyn/displayvideo_v1.advertisers.manualTriggers.html
+++ b/docs/dyn/displayvideo_v1.advertisers.manualTriggers.html
@@ -90,7 +90,7 @@
   <code><a href="#get">get(advertiserId, triggerId, x__xgafv=None)</a></code></p>
 <p class="firstline">Gets a manual trigger.</p>
 <p class="toc_element">
-  <code><a href="#list">list(advertiserId, pageSize=None, orderBy=None, pageToken=None, filter=None, x__xgafv=None)</a></code></p>
+  <code><a href="#list">list(advertiserId, filter=None, orderBy=None, pageSize=None, pageToken=None, x__xgafv=None)</a></code></p>
 <p class="firstline">Lists manual triggers that are accessible to the current user for a given advertiser ID. The order is defined by the order_by parameter. A single advertiser_id is required.</p>
 <p class="toc_element">
   <code><a href="#list_next">list_next(previous_request, previous_response)</a></code></p>
@@ -110,7 +110,7 @@
     The object takes the form of:
 
 { # Request message for ManualTriggerService.ActivateManualTrigger.
-  }
+}
 
   x__xgafv: string, V1 error format.
     Allowed values
@@ -121,14 +121,14 @@
   An object of the form:
 
     { # A single manual trigger in Display &amp; Video 360.
-      &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-      &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-      &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-      &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-      &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-      &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-      &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-    }</pre>
+  &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+  &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+  &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+  &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+  &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+  &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+  &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+}</pre>
 </div>
 
 <div class="method">
@@ -146,14 +146,14 @@
     The object takes the form of:
 
 { # A single manual trigger in Display &amp; Video 360.
-    &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-    &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-    &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-    &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-    &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-    &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-    &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-  }
+  &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+  &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+  &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+  &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+  &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+  &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+  &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+}
 
   x__xgafv: string, V1 error format.
     Allowed values
@@ -164,14 +164,14 @@
   An object of the form:
 
     { # A single manual trigger in Display &amp; Video 360.
-      &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-      &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-      &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-      &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-      &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-      &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-      &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-    }</pre>
+  &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+  &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+  &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+  &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+  &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+  &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+  &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+}</pre>
 </div>
 
 <div class="method">
@@ -185,7 +185,7 @@
     The object takes the form of:
 
 { # Request message for ManualTriggerService.DeactivateManualTrigger.
-  }
+}
 
   x__xgafv: string, V1 error format.
     Allowed values
@@ -196,14 +196,14 @@
   An object of the form:
 
     { # A single manual trigger in Display &amp; Video 360.
-      &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-      &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-      &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-      &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-      &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-      &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-      &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-    }</pre>
+  &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+  &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+  &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+  &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+  &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+  &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+  &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+}</pre>
 </div>
 
 <div class="method">
@@ -222,26 +222,26 @@
   An object of the form:
 
     { # A single manual trigger in Display &amp; Video 360.
-      &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-      &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-      &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-      &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-      &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-      &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-      &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-    }</pre>
+  &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+  &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+  &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+  &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+  &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+  &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+  &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+}</pre>
 </div>
 
 <div class="method">
-    <code class="details" id="list">list(advertiserId, pageSize=None, orderBy=None, pageToken=None, filter=None, x__xgafv=None)</code>
+    <code class="details" id="list">list(advertiserId, filter=None, orderBy=None, pageSize=None, pageToken=None, x__xgafv=None)</code>
   <pre>Lists manual triggers that are accessible to the current user for a given advertiser ID. The order is defined by the order_by parameter. A single advertiser_id is required.
 
 Args:
   advertiserId: string, Required. The ID of the advertiser that the fetched manual triggers belong to. (required)
-  pageSize: integer, Requested page size. Must be between `1` and `100`. If unspecified will default to `100`.
-  orderBy: string, Field by which to sort the list. Acceptable values are: * `displayName` (default) * `state` The default sorting order is ascending. To specify descending order for a field, a suffix &quot;desc&quot; should be added to the field name. For example, `displayName desc`.
-  pageToken: string, A token identifying a page of results the server should return. Typically, this is the value of next_page_token returned from the previous call to `ListManualTriggers` method. If not specified, the first page of results will be returned.
   filter: string, Allows filtering by manual trigger properties. Supported syntax: * Filter expressions are made up of one or more restrictions. * Restrictions can be combined by `AND` or `OR` logical operators. A sequence of restrictions implicitly uses `AND`. * A restriction has the form of `{field} {operator} {value}`. * The operator must be `EQUALS (=)`. * Supported fields: - `displayName` - `state` Examples: * All active manual triggers under an advertiser: `state=&quot;ACTIVE&quot;` The length of this field should be no more than 500 characters.
+  orderBy: string, Field by which to sort the list. Acceptable values are: * `displayName` (default) * `state` The default sorting order is ascending. To specify descending order for a field, a suffix &quot;desc&quot; should be added to the field name. For example, `displayName desc`.
+  pageSize: integer, Requested page size. Must be between `1` and `100`. If unspecified will default to `100`.
+  pageToken: string, A token identifying a page of results the server should return. Typically, this is the value of next_page_token returned from the previous call to `ListManualTriggers` method. If not specified, the first page of results will be returned.
   x__xgafv: string, V1 error format.
     Allowed values
       1 - v1 error format
@@ -251,19 +251,19 @@
   An object of the form:
 
     {
-    &quot;manualTriggers&quot;: [ # The list of manual triggers. This list will be absent if empty.
-      { # A single manual trigger in Display &amp; Video 360.
-          &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-          &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-          &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-          &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-          &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-          &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-          &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-        },
-    ],
-    &quot;nextPageToken&quot;: &quot;A String&quot;, # A token to retrieve the next page of results. Pass this value in the page_token field in the subsequent call to `ListManualTriggers` method to retrieve the next page of results.
-  }</pre>
+  &quot;manualTriggers&quot;: [ # The list of manual triggers. This list will be absent if empty.
+    { # A single manual trigger in Display &amp; Video 360.
+      &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+      &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+      &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+      &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+      &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+      &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+      &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+    },
+  ],
+  &quot;nextPageToken&quot;: &quot;A String&quot;, # A token to retrieve the next page of results. Pass this value in the page_token field in the subsequent call to `ListManualTriggers` method to retrieve the next page of results.
+}</pre>
 </div>
 
 <div class="method">
@@ -291,14 +291,14 @@
     The object takes the form of:
 
 { # A single manual trigger in Display &amp; Video 360.
-    &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-    &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-    &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-    &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-    &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-    &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-    &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-  }
+  &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+  &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+  &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+  &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+  &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+  &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+  &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+}
 
   updateMask: string, Required. The mask to control which fields to update.
   x__xgafv: string, V1 error format.
@@ -310,14 +310,14 @@
   An object of the form:
 
     { # A single manual trigger in Display &amp; Video 360.
-      &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
-      &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
-      &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
-      &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
-      &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
-      &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
-      &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
-    }</pre>
+  &quot;activationDurationMinutes&quot;: &quot;A String&quot;, # Required. The maximum duration of each activation in minutes. Must be between 1 and 360 inclusive. After this duration, the trigger will be automatically deactivated.
+  &quot;advertiserId&quot;: &quot;A String&quot;, # Required. Immutable. The unique ID of the advertiser that the manual trigger belongs to.
+  &quot;displayName&quot;: &quot;A String&quot;, # Required. The display name of the manual trigger. Must be UTF-8 encoded with a maximum size of 240 bytes.
+  &quot;latestActivationTime&quot;: &quot;A String&quot;, # Output only. The timestamp of the trigger&#x27;s latest activation.
+  &quot;name&quot;: &quot;A String&quot;, # Output only. The resource name of the manual trigger.
+  &quot;state&quot;: &quot;A String&quot;, # Output only. The state of the manual trigger. Will be set to the `INACTIVE` state upon creation.
+  &quot;triggerId&quot;: &quot;A String&quot;, # Output only. The unique ID of the manual trigger.
+}</pre>
 </div>
 
 </body></html>
\ No newline at end of file