| /* |
| * Copyright (C) 2018 The Android Open Source Project |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| package android.hardware.biometrics; |
| |
| import android.annotation.UnsupportedAppUsage; |
| import android.app.KeyguardManager; |
| |
| |
| /** |
| * Interface containing all of the biometric modality agnostic constants. |
| * |
| * NOTE: The error messages must be consistent between BiometricConstants, Biometric*Constants, |
| * and the frameworks/support/biometric/.../BiometricConstants files. |
| * |
| * @hide |
| */ |
| public interface BiometricConstants { |
| // |
| // Error messages from biometric hardware during initilization, enrollment, authentication or |
| // removal. |
| // |
| |
| /** |
| * This was not added here since it would update BiometricPrompt API. But, is used in |
| * BiometricManager. |
| * @hide |
| */ |
| int BIOMETRIC_SUCCESS = 0; |
| |
| /** |
| * The hardware is unavailable. Try again later. |
| */ |
| int BIOMETRIC_ERROR_HW_UNAVAILABLE = 1; |
| |
| /** |
| * Error state returned when the sensor was unable to process the current image. |
| */ |
| int BIOMETRIC_ERROR_UNABLE_TO_PROCESS = 2; |
| |
| /** |
| * Error state returned when the current request has been running too long. This is intended to |
| * prevent programs from waiting for the biometric sensor indefinitely. The timeout is platform |
| * and sensor-specific, but is generally on the order of 30 seconds. |
| */ |
| int BIOMETRIC_ERROR_TIMEOUT = 3; |
| |
| /** |
| * Error state returned for operations like enrollment; the operation cannot be completed |
| * because there's not enough storage remaining to complete the operation. |
| */ |
| int BIOMETRIC_ERROR_NO_SPACE = 4; |
| |
| /** |
| * The operation was canceled because the biometric sensor is unavailable. For example, this may |
| * happen when the user is switched, the device is locked or another pending operation prevents |
| * or disables it. |
| */ |
| int BIOMETRIC_ERROR_CANCELED = 5; |
| |
| /** |
| * The {@link BiometricManager#remove} call failed. Typically this will happen when the provided |
| * biometric id was incorrect. |
| * |
| * @hide |
| */ |
| int BIOMETRIC_ERROR_UNABLE_TO_REMOVE = 6; |
| |
| /** |
| * The operation was canceled because the API is locked out due to too many attempts. |
| * This occurs after 5 failed attempts, and lasts for 30 seconds. |
| */ |
| int BIOMETRIC_ERROR_LOCKOUT = 7; |
| |
| /** |
| * Hardware vendors may extend this list if there are conditions that do not fall under one of |
| * the above categories. Vendors are responsible for providing error strings for these errors. |
| * These messages are typically reserved for internal operations such as enrollment, but may be |
| * used to express vendor errors not otherwise covered. Applications are expected to show the |
| * error message string if they happen, but are advised not to rely on the message id since they |
| * will be device and vendor-specific |
| */ |
| int BIOMETRIC_ERROR_VENDOR = 8; |
| |
| /** |
| * The operation was canceled because BIOMETRIC_ERROR_LOCKOUT occurred too many times. |
| * Biometric authentication is disabled until the user unlocks with strong authentication |
| * (PIN/Pattern/Password) |
| */ |
| int BIOMETRIC_ERROR_LOCKOUT_PERMANENT = 9; |
| |
| /** |
| * The user canceled the operation. Upon receiving this, applications should use alternate |
| * authentication (e.g. a password). The application should also provide the means to return to |
| * biometric authentication, such as a "use <biometric>" button. |
| */ |
| int BIOMETRIC_ERROR_USER_CANCELED = 10; |
| |
| /** |
| * The user does not have any biometrics enrolled. |
| */ |
| int BIOMETRIC_ERROR_NO_BIOMETRICS = 11; |
| |
| /** |
| * The device does not have a biometric sensor. |
| */ |
| int BIOMETRIC_ERROR_HW_NOT_PRESENT = 12; |
| |
| /** |
| * The user pressed the negative button. This is a placeholder that is currently only used |
| * by the support library. |
| * @hide |
| */ |
| int BIOMETRIC_ERROR_NEGATIVE_BUTTON = 13; |
| |
| /** |
| * The device does not have pin, pattern, or password set up. See |
| * {@link BiometricPrompt.Builder#setDeviceCredentialAllowed(boolean)} and |
| * {@link KeyguardManager#isDeviceSecure()} |
| */ |
| int BIOMETRIC_ERROR_NO_DEVICE_CREDENTIAL = 14; |
| |
| /** |
| * @hide |
| */ |
| @UnsupportedAppUsage |
| int BIOMETRIC_ERROR_VENDOR_BASE = 1000; |
| |
| // |
| // Image acquisition messages. |
| // |
| |
| /** |
| * The image acquired was good. |
| */ |
| int BIOMETRIC_ACQUIRED_GOOD = 0; |
| |
| /** |
| * Only a partial biometric image was detected. During enrollment, the user should be informed |
| * on what needs to happen to resolve this problem, e.g. "press firmly on sensor." (for |
| * fingerprint) |
| */ |
| int BIOMETRIC_ACQUIRED_PARTIAL = 1; |
| |
| /** |
| * The biometric image was too noisy to process due to a detected condition or a possibly dirty |
| * sensor (See {@link #BIOMETRIC_ACQUIRED_IMAGER_DIRTY}). |
| */ |
| int BIOMETRIC_ACQUIRED_INSUFFICIENT = 2; |
| |
| /** |
| * The biometric image was too noisy due to suspected or detected dirt on the sensor. For |
| * example, it's reasonable return this after multiple {@link #BIOMETRIC_ACQUIRED_INSUFFICIENT} |
| * or actual detection of dirt on the sensor (stuck pixels, swaths, etc.). The user is expected |
| * to take action to clean the sensor when this is returned. |
| */ |
| int BIOMETRIC_ACQUIRED_IMAGER_DIRTY = 3; |
| |
| /** |
| * The biometric image was unreadable due to lack of motion. |
| */ |
| int BIOMETRIC_ACQUIRED_TOO_SLOW = 4; |
| |
| /** |
| * The biometric image was incomplete due to quick motion. For example, this could also happen |
| * if the user moved during acquisition. The user should be asked to repeat the operation more |
| * slowly. |
| */ |
| int BIOMETRIC_ACQUIRED_TOO_FAST = 5; |
| |
| /** |
| * Hardware vendors may extend this list if there are conditions that do not fall under one of |
| * the above categories. Vendors are responsible for providing error strings for these errors. |
| * @hide |
| */ |
| int BIOMETRIC_ACQUIRED_VENDOR = 6; |
| /** |
| * @hide |
| */ |
| int BIOMETRIC_ACQUIRED_VENDOR_BASE = 1000; |
| } |