commit | c2400dfd02c7209213474f0a82865a63d2a8b2e0 | [log] [tgz] |
---|---|---|
author | Pierre Frojd <pierre.frojd@sonyericsson.com> | Tue Oct 05 17:57:33 2010 +0200 |
committer | Johan Redestig <johan.redestig@sonyericsson.com> | Tue Jan 04 07:44:11 2011 +0100 |
tree | 82160035342f4008f9c76cdfaf8acce5930d06af | |
parent | fdf7d8e43952c5cbf09c6e22fb5fbfaaea626f93 [diff] |
Fix missinterpretation of tenth-of-second When the PLAY TONE command from Sim tool kit has a duration time with the time unit of "Tenth of seconds", this is missinterpreted by StkApp as "Ten times seconds". See 3GPP TS 11.14 page 113. Change-Id: If7123f894f5476258aa5b94ba99460d8778c75f1