Fix missinterpretation of tenth-of-second

When the PLAY TONE command from Sim tool kit has a duration time
with the time unit of "Tenth of seconds", this is missinterpreted
by StkApp as "Ten times seconds". See 3GPP TS 11.14 page 113.

Change-Id: If7123f894f5476258aa5b94ba99460d8778c75f1