healthd: Adds fake battery properties for devices with no battery.

Devices which have no battery and are always plugged in will not have
any battery property initialized. This causes the 'stable power' to
never be switched which is required for updating apps.

This change recognizes such a device and manually sets the battery to
100% and charger status to connected to AC mains. It will also fake the
battery temperature.

Bug: 24258855
Change-Id: I98e5ed0dbeb7f2ab6d3802cd7e0f3a269bd8f31f
Signed-off-by: Ruchi Kandoi <kandoiruchi@google.com>
diff --git a/healthd/BatteryMonitor.cpp b/healthd/BatteryMonitor.cpp
index cb77a8e..ae63890 100644
--- a/healthd/BatteryMonitor.cpp
+++ b/healthd/BatteryMonitor.cpp
@@ -39,6 +39,7 @@
 #define POWER_SUPPLY_SYSFS_PATH "/sys/class/" POWER_SUPPLY_SUBSYSTEM
 #define FAKE_BATTERY_CAPACITY 42
 #define FAKE_BATTERY_TEMPERATURE 424
+#define ALWAYS_PLUGGED_CAPACITY 100
 
 namespace android {
 
@@ -208,6 +209,15 @@
         mBatteryFixedTemperature :
         getIntField(mHealthdConfig->batteryTemperaturePath);
 
+    // For devices which do not have battery and are always plugged
+    // into power souce.
+    if (mAlwaysPluggedDevice) {
+        props.chargerAcOnline = true;
+        props.batteryPresent = true;
+        props.batteryStatus = BATTERY_STATUS_CHARGING;
+        props.batteryHealth = BATTERY_HEALTH_GOOD;
+    }
+
     const int SIZE = 128;
     char buf[SIZE];
     String8 btech;
@@ -590,8 +600,12 @@
         closedir(dir);
     }
 
-    if (!mChargerNames.size())
+    if (!mChargerNames.size()) {
         KLOG_ERROR(LOG_TAG, "No charger supplies found\n");
+        mBatteryFixedCapacity = ALWAYS_PLUGGED_CAPACITY;
+        mBatteryFixedTemperature = FAKE_BATTERY_TEMPERATURE;
+        mAlwaysPluggedDevice = true;
+    }
     if (!mBatteryDevicePresent) {
         KLOG_WARNING(LOG_TAG, "No battery devices found\n");
         hc->periodic_chores_interval_fast = -1;
@@ -611,7 +625,7 @@
             KLOG_WARNING(LOG_TAG, "BatteryTemperaturePath not found\n");
         if (mHealthdConfig->batteryTechnologyPath.isEmpty())
             KLOG_WARNING(LOG_TAG, "BatteryTechnologyPath not found\n");
-	if (mHealthdConfig->batteryCurrentNowPath.isEmpty())
+        if (mHealthdConfig->batteryCurrentNowPath.isEmpty())
             KLOG_WARNING(LOG_TAG, "BatteryCurrentNowPath not found\n");