NAN: Cleanup NAN data interface on nanop off

Failure to delete NDI on nanop off was leading to many stale parameters
being used for the next NDI session.

Fix by deleting NDI on nanop off, helps clear all the parameters from
the preceding NDI session.

Signed-off-by: Jouni Malinen <jouni@qca.qualcomm.com>