blob: 8928e64473804887c06b7af6ed6faabc71a50476 [file] [log] [blame]
Zhang Rui203d3d42008-01-17 15:51:08 +08001#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
Zhang Rui63c4ec92008-04-21 16:07:13 +08006 tristate "Generic Thermal sysfs driver"
Zhang Rui203d3d42008-01-17 15:51:08 +08007 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
Len Brown543a9562008-02-07 16:55:08 -050011 Each thermal zone contains its own temperature, trip points,
Zhang Rui203d3d42008-01-17 15:51:08 +080012 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
Zhang Rui63c4ec92008-04-21 16:07:13 +080014 If you want this support, you should say Y or M here.
Rene Herman16d75232008-06-24 19:38:56 +020015
Zhang Rui72e19892012-11-15 09:16:20 +080016if THERMAL
17
Rene Herman16d75232008-06-24 19:38:56 +020018config THERMAL_HWMON
Jean Delvareab924022011-07-28 13:48:40 -070019 bool
Eduardo Valentin0dd88792013-07-03 15:14:28 -040020 prompt "Expose thermal sensors as hwmon device"
Rene Herman16d75232008-06-24 19:38:56 +020021 depends on HWMON=y || HWMON=THERMAL
Jean Delvareab924022011-07-28 13:48:40 -070022 default y
Eduardo Valentin0dd88792013-07-03 15:14:28 -040023 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
Vincenzo Frascino6a92c362012-03-21 12:55:03 -070031
Durgadoss Ra56757a2012-09-21 14:32:24 +053032choice
33 prompt "Default Thermal governor"
Durgadoss Ra56757a2012-09-21 14:32:24 +053034 default THERMAL_DEFAULT_GOV_STEP_WISE
35 help
36 This option sets which thermal governor shall be loaded at
37 startup. If in doubt, select 'step_wise'.
38
39config THERMAL_DEFAULT_GOV_STEP_WISE
40 bool "step_wise"
Zhang Rui9d185d02013-02-08 20:33:42 +080041 select THERMAL_GOV_STEP_WISE
Durgadoss Ra56757a2012-09-21 14:32:24 +053042 help
43 Use the step_wise governor as default. This throttles the
44 devices one step at a time.
45
46config THERMAL_DEFAULT_GOV_FAIR_SHARE
47 bool "fair_share"
Zhang Rui9d185d02013-02-08 20:33:42 +080048 select THERMAL_GOV_FAIR_SHARE
Durgadoss Ra56757a2012-09-21 14:32:24 +053049 help
50 Use the fair_share governor as default. This throttles the
51 devices based on their 'contribution' to a zone. The
52 contribution should be provided through platform data.
53
54config THERMAL_DEFAULT_GOV_USER_SPACE
55 bool "user_space"
Zhang Rui9d185d02013-02-08 20:33:42 +080056 select THERMAL_GOV_USER_SPACE
Durgadoss Ra56757a2012-09-21 14:32:24 +053057 help
58 Select this if you want to let the user space manage the
Regid Ichiraece238f2013-09-09 00:58:53 +030059 platform thermals.
Zhang Rui72e19892012-11-15 09:16:20 +080060
Durgadoss Ra56757a2012-09-21 14:32:24 +053061endchoice
Zhang Rui72e19892012-11-15 09:16:20 +080062
Zhang Rui9d185d02013-02-08 20:33:42 +080063config THERMAL_GOV_FAIR_SHARE
Zhang Rui72e19892012-11-15 09:16:20 +080064 bool "Fair-share thermal governor"
65 help
66 Enable this to manage platform thermals using fair-share governor.
67
Zhang Rui9d185d02013-02-08 20:33:42 +080068config THERMAL_GOV_STEP_WISE
Zhang Rui72e19892012-11-15 09:16:20 +080069 bool "Step_wise thermal governor"
70 help
71 Enable this to manage platform thermals using a simple linear
Luka Perkova8227942013-09-27 20:20:33 +020072 governor.
Zhang Rui72e19892012-11-15 09:16:20 +080073
Zhang Rui9d185d02013-02-08 20:33:42 +080074config THERMAL_GOV_USER_SPACE
Zhang Rui72e19892012-11-15 09:16:20 +080075 bool "User_space thermal governor"
76 help
77 Enable this to let the user space manage the platform thermals.
78
79config CPU_THERMAL
Zhang Ruibbf7fc82013-03-26 23:57:01 +080080 bool "generic cpu cooling support"
Zhang Rui72e19892012-11-15 09:16:20 +080081 depends on CPU_FREQ
Zhang Rui72e19892012-11-15 09:16:20 +080082 help
83 This implements the generic cpu cooling mechanism through frequency
Eduardo Valentinf7188b32013-04-17 17:12:10 +000084 reduction. An ACPI version of this already exists
85 (drivers/acpi/processor_thermal.c).
Zhang Rui72e19892012-11-15 09:16:20 +080086 This will be useful for platforms using the generic thermal interface
87 and not the ACPI interface.
Eduardo Valentinf7188b32013-04-17 17:12:10 +000088
Zhang Rui72e19892012-11-15 09:16:20 +080089 If you want this support, you should say Y here.
90
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +000091config THERMAL_EMULATION
92 bool "Thermal emulation mode support"
93 help
94 Enable this option to make a emul_temp sysfs node in thermal zone
95 directory to support temperature emulation. With emulation sysfs node,
96 user can manually input temperature and test the different trip
97 threshold behaviour for simulation purpose.
98
Eduardo Valentin88372952013-03-26 21:38:34 +000099 WARNING: Be careful while enabling this option on production systems,
100 because userland can easily disable the thermal policy by simply
101 flooding this sysfs node with low temperature values.
102
Shawn Guoca3de462013-06-24 14:30:44 +0800103config IMX_THERMAL
104 tristate "Temperature sensor driver for Freescale i.MX SoCs"
105 depends on CPU_THERMAL
106 depends on MFD_SYSCON
107 depends on OF
108 help
109 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
110 It supports one critical trip point and one passive trip point. The
111 cpufreq is used as the cooling device to throttle CPUs when the
112 passive trip is crossed.
113
Zhang Rui72e19892012-11-15 09:16:20 +0800114config SPEAR_THERMAL
115 bool "SPEAr thermal sensor driver"
116 depends on PLAT_SPEAR
117 depends on OF
118 help
119 Enable this to plug the SPEAr thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200120 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800121
122config RCAR_THERMAL
123 tristate "Renesas R-Car thermal driver"
124 depends on ARCH_SHMOBILE
125 help
126 Enable this to plug the R-Car thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200127 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800128
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000129config KIRKWOOD_THERMAL
130 tristate "Temperature sensor on Marvell Kirkwood SoCs"
131 depends on ARCH_KIRKWOOD
132 depends on OF
133 help
134 Support for the Kirkwood thermal sensor driver into the Linux thermal
135 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
136
Andrew Lunn74ffa642013-02-06 06:35:26 +0000137config DOVE_THERMAL
138 tristate "Temperature sensor on Marvell Dove SoCs"
139 depends on ARCH_DOVE
140 depends on OF
141 help
142 Support for the Dove thermal sensor driver in the Linux thermal
143 framework.
144
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800145config DB8500_THERMAL
146 bool "DB8500 thermal management"
147 depends on ARCH_U8500
148 default y
149 help
150 Adds DB8500 thermal management implementation according to the thermal
151 management framework. A thermal zone with several trip points will be
152 created. Cooling devices can be bound to the trip points to cool this
153 thermal zone if trip points reached.
154
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000155config ARMADA_THERMAL
156 tristate "Armada 370/XP thermal management"
157 depends on ARCH_MVEBU
158 depends on OF
159 help
160 Enable this option if you want to have support for thermal management
161 controller present in Armada 370 and Armada XP SoC.
162
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800163config DB8500_CPUFREQ_COOLING
164 tristate "DB8500 cpufreq cooling"
165 depends on ARCH_U8500
166 depends on CPU_THERMAL
167 default y
168 help
169 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
170 bound to thermal zone trip points. When a trip point reached, the
171 bound cpufreq cooling device turns active to set CPU frequency low to
172 cool down the CPU.
Zhang Rui72e19892012-11-15 09:16:20 +0800173
Jacob Pand6d71ee2013-01-21 04:37:57 -0800174config INTEL_POWERCLAMP
175 tristate "Intel PowerClamp idle injection driver"
176 depends on THERMAL
177 depends on X86
178 depends on CPU_SUP_INTEL
179 help
180 Enable this to enable Intel PowerClamp idle injection driver. This
181 enforce idle time which results in more package C-state residency. The
182 user interface is exposed via generic thermal framework.
183
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000184config X86_PKG_TEMP_THERMAL
185 tristate "X86 package temperature thermal driver"
Randy Dunlapb3ba0202013-06-17 12:27:17 -0700186 depends on X86_THERMAL_VECTOR
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000187 select THERMAL_GOV_USER_SPACE
188 default m
189 help
190 Enable this to register CPU digital sensor for package temperature as
191 thermal zone. Each package will have its own thermal zone. There are
192 two trip points which can be set by user to get notifications via thermal
193 notification methods.
194
Srinivas Pandruvada925c36b2013-12-30 12:55:06 -0800195config ACPI_INT3403_THERMAL
196 tristate "ACPI INT3403 thermal driver"
197 depends on X86 && ACPI
198 help
199 This driver uses ACPI INT3403 device objects. If present, it will
200 register each INT3403 thermal sensor as a thermal zone.
201
Eduardo Valentineb982002013-05-15 15:46:00 +0000202menu "Texas Instruments thermal drivers"
203source "drivers/thermal/ti-soc-thermal/Kconfig"
204endmenu
Zhang Ruif157f592013-06-18 06:31:26 +0800205
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530206menu "Samsung thermal drivers"
207depends on PLAT_SAMSUNG
208source "drivers/thermal/samsung/Kconfig"
209endmenu
210