| * Samsung S2MPS11 Voltage and Current Regulator |
| |
| The Samsung S2MP211 is a multi-function device which includes voltage and |
| current regulators, RTC, charger controller and other sub-blocks. It is |
| interfaced to the host controller using a I2C interface. Each sub-block is |
| addressed by the host system using different I2C slave address. |
| |
| Required properties: |
| - compatible: Should be "samsung,s2mps11-pmic". |
| - reg: Specifies the I2C slave address of the pmic block. It should be 0x66. |
| |
| Optional properties: |
| - interrupt-parent: Specifies the phandle of the interrupt controller to which |
| the interrupts from s2mps11 are delivered to. |
| - interrupts: Interrupt specifiers for interrupt sources. |
| |
| Optional nodes: |
| - regulators: The regulators of s2mps11 that have to be instantiated should be |
| included in a sub-node named 'regulators'. Regulator nodes included in this |
| sub-node should be of the format as listed below. |
| |
| regulator_name { |
| [standard regulator constraints....]; |
| }; |
| |
| regulator-ramp-delay for BUCKs = [6250/12500/25000(default)/50000] uV/us |
| |
| BUCK[2/3/4/6] supports disabling ramp delay on hardware, so explictly |
| regulator-ramp-delay = <0> can be used for them to disable ramp delay. |
| In absence of regulator-ramp-delay property, default ramp delay will be used. |
| |
| NOTE: Some BUCKs share the ramp rate setting i.e. same ramp value will be set |
| for a particular group of BUCKs. So provide same regulator-ramp-delay<value>. |
| Grouping of BUCKs sharing ramp rate setting is as follow : BUCK[1, 6], |
| BUCK[3, 4], and BUCK[7, 8, 10] |
| |
| The regulator constraints inside the regulator nodes use the standard regulator |
| bindings which are documented elsewhere. |
| |
| The following are the names of the regulators that the s2mps11 pmic block |
| supports. Note: The 'n' in LDOn and BUCKn represents the LDO or BUCK number |
| as per the datasheet of s2mps11. |
| |
| - LDOn |
| - valid values for n are 1 to 28 |
| - Example: LDO0, LD01, LDO28 |
| - BUCKn |
| - valid values for n are 1 to 9. |
| - Example: BUCK1, BUCK2, BUCK9 |
| |
| Example: |
| |
| s2mps11_pmic@66 { |
| compatible = "samsung,s2mps11-pmic"; |
| reg = <0x66>; |
| |
| regulators { |
| ldo1_reg: LDO1 { |
| regulator-name = "VDD_ABB_3.3V"; |
| regulator-min-microvolt = <3300000>; |
| regulator-max-microvolt = <3300000>; |
| }; |
| |
| ldo2_reg: LDO2 { |
| regulator-name = "VDD_ALIVE_1.1V"; |
| regulator-min-microvolt = <1100000>; |
| regulator-max-microvolt = <1100000>; |
| regulator-always-on; |
| }; |
| |
| buck1_reg: BUCK1 { |
| regulator-name = "vdd_mif"; |
| regulator-min-microvolt = <950000>; |
| regulator-max-microvolt = <1350000>; |
| regulator-always-on; |
| regulator-boot-on; |
| }; |
| |
| buck2_reg: BUCK2 { |
| regulator-name = "vdd_arm"; |
| regulator-min-microvolt = <950000>; |
| regulator-max-microvolt = <1350000>; |
| regulator-always-on; |
| regulator-boot-on; |
| regulator-ramp-delay = <50000>; |
| }; |
| }; |
| }; |