blob: 7a96c0650fbbc1daf8c3fdf1dbc699a66b7d7a32 [file] [log] [blame]
#include <linux/export.h>
#include <linux/power_supply.h>
#include <linux/of.h>
#include <linux/mfd/abx500.h>
#include <linux/mfd/abx500/ab8500.h>
#include <linux/mfd/abx500/ab8500-bm.h>
/*
* These are the defined batteries that uses a NTC and ID resistor placed
* inside of the battery pack.
* Note that the res_to_temp table must be strictly sorted by falling resistance
* values to work.
*/
static struct abx500_res_to_temp temp_tbl_A_thermistor[] = {
{-5, 53407},
{ 0, 48594},
{ 5, 43804},
{10, 39188},
{15, 34870},
{20, 30933},
{25, 27422},
{30, 24347},
{35, 21694},
{40, 19431},
{45, 17517},
{50, 15908},
{55, 14561},
{60, 13437},
{65, 12500},
};
static struct abx500_res_to_temp temp_tbl_B_thermistor[] = {
{-5, 200000},
{ 0, 159024},
{ 5, 151921},
{10, 144300},
{15, 136424},
{20, 128565},
{25, 120978},
{30, 113875},
{35, 107397},
{40, 101629},
{45, 96592},
{50, 92253},
{55, 88569},
{60, 85461},
{65, 82869},
};
static struct abx500_v_to_cap cap_tbl_A_thermistor[] = {
{4171, 100},
{4114, 95},
{4009, 83},
{3947, 74},
{3907, 67},
{3863, 59},
{3830, 56},
{3813, 53},
{3791, 46},
{3771, 33},
{3754, 25},
{3735, 20},
{3717, 17},
{3681, 13},
{3664, 8},
{3651, 6},
{3635, 5},
{3560, 3},
{3408, 1},
{3247, 0},
};
static struct abx500_v_to_cap cap_tbl_B_thermistor[] = {
{4161, 100},
{4124, 98},
{4044, 90},
{4003, 85},
{3966, 80},
{3933, 75},
{3888, 67},
{3849, 60},
{3813, 55},
{3787, 47},
{3772, 30},
{3751, 25},
{3718, 20},
{3681, 16},
{3660, 14},
{3589, 10},
{3546, 7},
{3495, 4},
{3404, 2},
{3250, 0},
};
static struct abx500_v_to_cap cap_tbl[] = {
{4186, 100},
{4163, 99},
{4114, 95},
{4068, 90},
{3990, 80},
{3926, 70},
{3898, 65},
{3866, 60},
{3833, 55},
{3812, 50},
{3787, 40},
{3768, 30},
{3747, 25},
{3730, 20},
{3705, 15},
{3699, 14},
{3684, 12},
{3672, 9},
{3657, 7},
{3638, 6},
{3556, 4},
{3424, 2},
{3317, 1},
{3094, 0},
};
/*
* Note that the res_to_temp table must be strictly sorted by falling
* resistance values to work.
*/
static struct abx500_res_to_temp temp_tbl[] = {
{-5, 214834},
{ 0, 162943},
{ 5, 124820},
{10, 96520},
{15, 75306},
{20, 59254},
{25, 47000},
{30, 37566},
{35, 30245},
{40, 24520},
{45, 20010},
{50, 16432},
{55, 13576},
{60, 11280},
{65, 9425},
};
/*
* Note that the batres_vs_temp table must be strictly sorted by falling
* temperature values to work.
*/
static struct batres_vs_temp temp_to_batres_tbl_thermistor[] = {
{ 40, 120},
{ 30, 135},
{ 20, 165},
{ 10, 230},
{ 00, 325},
{-10, 445},
{-20, 595},
};
/*
* Note that the batres_vs_temp table must be strictly sorted by falling
* temperature values to work.
*/
static struct batres_vs_temp temp_to_batres_tbl_ext_thermistor[] = {
{ 60, 300},
{ 30, 300},
{ 20, 300},
{ 10, 300},
{ 00, 300},
{-10, 300},
{-20, 300},
};
/* battery resistance table for LI ION 9100 battery */
static struct batres_vs_temp temp_to_batres_tbl_9100[] = {
{ 60, 180},
{ 30, 180},
{ 20, 180},
{ 10, 180},
{ 00, 180},
{-10, 180},
{-20, 180},
};
static struct abx500_battery_type bat_type_thermistor[] = {
[BATTERY_UNKNOWN] = {
/* First element always represent the UNKNOWN battery */
.name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN,
.resis_high = 0,
.resis_low = 0,
.battery_resistance = 300,
.charge_full_design = 612,
.nominal_voltage = 3700,
.termination_vol = 4050,
.termination_curr = 200,
.recharge_cap = 95,
.normal_cur_lvl = 400,
.normal_vol_lvl = 4100,
.maint_a_cur_lvl = 400,
.maint_a_vol_lvl = 4050,
.maint_a_chg_timer_h = 60,
.maint_b_cur_lvl = 400,
.maint_b_vol_lvl = 4000,
.maint_b_chg_timer_h = 200,
.low_high_cur_lvl = 300,
.low_high_vol_lvl = 4000,
.n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
.r_to_t_tbl = temp_tbl,
.n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
.v_to_cap_tbl = cap_tbl,
.n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
.batres_tbl = temp_to_batres_tbl_thermistor,
},
{
.name = POWER_SUPPLY_TECHNOLOGY_LIPO,
.resis_high = 53407,
.resis_low = 12500,
.battery_resistance = 300,
.charge_full_design = 900,
.nominal_voltage = 3600,
.termination_vol = 4150,
.termination_curr = 80,
.recharge_cap = 95,
.normal_cur_lvl = 700,
.normal_vol_lvl = 4200,
.maint_a_cur_lvl = 600,
.maint_a_vol_lvl = 4150,
.maint_a_chg_timer_h = 60,
.maint_b_cur_lvl = 600,
.maint_b_vol_lvl = 4100,
.maint_b_chg_timer_h = 200,
.low_high_cur_lvl = 300,
.low_high_vol_lvl = 4000,
.n_temp_tbl_elements = ARRAY_SIZE(temp_tbl_A_thermistor),
.r_to_t_tbl = temp_tbl_A_thermistor,
.n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_A_thermistor),
.v_to_cap_tbl = cap_tbl_A_thermistor,
.n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
.batres_tbl = temp_to_batres_tbl_thermistor,
},
{
.name = POWER_SUPPLY_TECHNOLOGY_LIPO,
.resis_high = 200000,
.resis_low = 82869,
.battery_resistance = 300,
.charge_full_design = 900,
.nominal_voltage = 3600,
.termination_vol = 4150,
.termination_curr = 80,
.recharge_cap = 95,
.normal_cur_lvl = 700,
.normal_vol_lvl = 4200,
.maint_a_cur_lvl = 600,
.maint_a_vol_lvl = 4150,
.maint_a_chg_timer_h = 60,
.maint_b_cur_lvl = 600,
.maint_b_vol_lvl = 4100,
.maint_b_chg_timer_h = 200,
.low_high_cur_lvl = 300,
.low_high_vol_lvl = 4000,
.n_temp_tbl_elements = ARRAY_SIZE(temp_tbl_B_thermistor),
.r_to_t_tbl = temp_tbl_B_thermistor,
.n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl_B_thermistor),
.v_to_cap_tbl = cap_tbl_B_thermistor,
.n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
.batres_tbl = temp_to_batres_tbl_thermistor,
},
};
static struct abx500_battery_type bat_type_ext_thermistor[] = {
[BATTERY_UNKNOWN] = {
/* First element always represent the UNKNOWN battery */
.name = POWER_SUPPLY_TECHNOLOGY_UNKNOWN,
.resis_high = 0,
.resis_low = 0,
.battery_resistance = 300,
.charge_full_design = 612,
.nominal_voltage = 3700,
.termination_vol = 4050,
.termination_curr = 200,
.recharge_cap = 95,
.normal_cur_lvl = 400,
.normal_vol_lvl = 4100,
.maint_a_cur_lvl = 400,
.maint_a_vol_lvl = 4050,
.maint_a_chg_timer_h = 60,
.maint_b_cur_lvl = 400,
.maint_b_vol_lvl = 4000,
.maint_b_chg_timer_h = 200,
.low_high_cur_lvl = 300,
.low_high_vol_lvl = 4000,
.n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
.r_to_t_tbl = temp_tbl,
.n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
.v_to_cap_tbl = cap_tbl,
.n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
.batres_tbl = temp_to_batres_tbl_thermistor,
},
/*
* These are the batteries that doesn't have an internal NTC resistor to measure
* its temperature. The temperature in this case is measure with a NTC placed
* near the battery but on the PCB.
*/
{
.name = POWER_SUPPLY_TECHNOLOGY_LIPO,
.resis_high = 76000,
.resis_low = 53000,
.battery_resistance = 300,
.charge_full_design = 900,
.nominal_voltage = 3700,
.termination_vol = 4150,
.termination_curr = 100,
.recharge_cap = 95,
.normal_cur_lvl = 700,
.normal_vol_lvl = 4200,
.maint_a_cur_lvl = 600,
.maint_a_vol_lvl = 4150,
.maint_a_chg_timer_h = 60,
.maint_b_cur_lvl = 600,
.maint_b_vol_lvl = 4100,
.maint_b_chg_timer_h = 200,
.low_high_cur_lvl = 300,
.low_high_vol_lvl = 4000,
.n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
.r_to_t_tbl = temp_tbl,
.n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
.v_to_cap_tbl = cap_tbl,
.n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
.batres_tbl = temp_to_batres_tbl_thermistor,
},
{
.name = POWER_SUPPLY_TECHNOLOGY_LION,
.resis_high = 30000,
.resis_low = 10000,
.battery_resistance = 300,
.charge_full_design = 950,
.nominal_voltage = 3700,
.termination_vol = 4150,
.termination_curr = 100,
.recharge_cap = 95,
.normal_cur_lvl = 700,
.normal_vol_lvl = 4200,
.maint_a_cur_lvl = 600,
.maint_a_vol_lvl = 4150,
.maint_a_chg_timer_h = 60,
.maint_b_cur_lvl = 600,
.maint_b_vol_lvl = 4100,
.maint_b_chg_timer_h = 200,
.low_high_cur_lvl = 300,
.low_high_vol_lvl = 4000,
.n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
.r_to_t_tbl = temp_tbl,
.n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
.v_to_cap_tbl = cap_tbl,
.n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
.batres_tbl = temp_to_batres_tbl_thermistor,
},
{
.name = POWER_SUPPLY_TECHNOLOGY_LION,
.resis_high = 95000,
.resis_low = 76001,
.battery_resistance = 300,
.charge_full_design = 950,
.nominal_voltage = 3700,
.termination_vol = 4150,
.termination_curr = 100,
.recharge_cap = 95,
.normal_cur_lvl = 700,
.normal_vol_lvl = 4200,
.maint_a_cur_lvl = 600,
.maint_a_vol_lvl = 4150,
.maint_a_chg_timer_h = 60,
.maint_b_cur_lvl = 600,
.maint_b_vol_lvl = 4100,
.maint_b_chg_timer_h = 200,
.low_high_cur_lvl = 300,
.low_high_vol_lvl = 4000,
.n_temp_tbl_elements = ARRAY_SIZE(temp_tbl),
.r_to_t_tbl = temp_tbl,
.n_v_cap_tbl_elements = ARRAY_SIZE(cap_tbl),
.v_to_cap_tbl = cap_tbl,
.n_batres_tbl_elements = ARRAY_SIZE(temp_to_batres_tbl_thermistor),
.batres_tbl = temp_to_batres_tbl_thermistor,
},
};
static const struct abx500_bm_capacity_levels cap_levels = {
.critical = 2,
.low = 10,
.normal = 70,
.high = 95,
.full = 100,
};
static const struct abx500_fg_parameters fg = {
.recovery_sleep_timer = 10,
.recovery_total_time = 100,
.init_timer = 1,
.init_discard_time = 5,
.init_total_time = 40,
.high_curr_time = 60,
.accu_charging = 30,
.accu_high_curr = 30,
.high_curr_threshold = 50,
.lowbat_threshold = 3100,
.battok_falling_th_sel0 = 2860,
.battok_raising_th_sel1 = 2860,
.maint_thres = 95,
.user_cap_limit = 15,
};
static const struct abx500_maxim_parameters maxi_params = {
.ena_maxi = true,
.chg_curr = 910,
.wait_cycles = 10,
.charger_curr_step = 100,
};
static const struct abx500_bm_charger_parameters chg = {
.usb_volt_max = 5500,
.usb_curr_max = 1500,
.ac_volt_max = 7500,
.ac_curr_max = 1500,
};
struct abx500_bm_data ab8500_bm_data = {
.temp_under = 3,
.temp_low = 8,
.temp_high = 43,
.temp_over = 48,
.main_safety_tmr_h = 4,
.temp_interval_chg = 20,
.temp_interval_nochg = 120,
.usb_safety_tmr_h = 4,
.bkup_bat_v = BUP_VCH_SEL_2P6V,
.bkup_bat_i = BUP_ICH_SEL_150UA,
.no_maintenance = false,
.capacity_scaling = false,
.adc_therm = ABx500_ADC_THERM_BATCTRL,
.chg_unknown_bat = false,
.enable_overshoot = false,
.fg_res = 100,
.cap_levels = &cap_levels,
.bat_type = bat_type_thermistor,
.n_btypes = 3,
.batt_id = 0,
.interval_charging = 5,
.interval_not_charging = 120,
.temp_hysteresis = 3,
.gnd_lift_resistance = 34,
.maxi = &maxi_params,
.chg_params = &chg,
.fg_params = &fg,
};
int ab8500_bm_of_probe(struct device *dev,
struct device_node *np,
struct abx500_bm_data *bm)
{
struct batres_vs_temp *tmp_batres_tbl;
struct device_node *battery_node;
const char *btech;
int i;
/* get phandle to 'battery-info' node */
battery_node = of_parse_phandle(np, "battery", 0);
if (!battery_node) {
dev_err(dev, "battery node or reference missing\n");
return -EINVAL;
}
btech = of_get_property(battery_node, "stericsson,battery-type", NULL);
if (!btech) {
dev_warn(dev, "missing property battery-name/type\n");
return -EINVAL;
}
if (strncmp(btech, "LION", 4) == 0) {
bm->no_maintenance = true;
bm->chg_unknown_bat = true;
bm->bat_type[BATTERY_UNKNOWN].charge_full_design = 2600;
bm->bat_type[BATTERY_UNKNOWN].termination_vol = 4150;
bm->bat_type[BATTERY_UNKNOWN].recharge_cap = 95;
bm->bat_type[BATTERY_UNKNOWN].normal_cur_lvl = 520;
bm->bat_type[BATTERY_UNKNOWN].normal_vol_lvl = 4200;
}
if (of_property_read_bool(battery_node, "thermistor-on-batctrl")) {
if (strncmp(btech, "LION", 4) == 0)
tmp_batres_tbl = temp_to_batres_tbl_9100;
else
tmp_batres_tbl = temp_to_batres_tbl_thermistor;
} else {
bm->n_btypes = 4;
bm->bat_type = bat_type_ext_thermistor;
bm->adc_therm = ABx500_ADC_THERM_BATTEMP;
tmp_batres_tbl = temp_to_batres_tbl_ext_thermistor;
}
/* select the battery resolution table */
for (i = 0; i < bm->n_btypes; ++i)
bm->bat_type[i].batres_tbl = tmp_batres_tbl;
of_node_put(battery_node);
return 0;
}