| * linux/drivers/thermal/cpu_cooling.c |
| * |
| * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) |
| * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org> |
| * |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| * This program is free software; you can redistribute it and/or modify |
| * it under the terms of the GNU General Public License as published by |
| * the Free Software Foundation; version 2 of the License. |
| * |
| * This program is distributed in the hope that it will be useful, but |
| * WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU |
| * General Public License for more details. |
| * |
| * You should have received a copy of the GNU General Public License along |
| * with this program; if not, write to the Free Software Foundation, Inc., |
| * 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA. |
| * |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| */ |
| #include <linux/kernel.h> |
| #include <linux/module.h> |
| #include <linux/thermal.h> |
| #include <linux/platform_device.h> |
| #include <linux/cpufreq.h> |
| #include <linux/err.h> |
| #include <linux/slab.h> |
| #include <linux/cpu.h> |
| #include <linux/cpu_cooling.h> |
| |
| /** |
| * struct cpufreq_cooling_device |
| * @id: unique integer value corresponding to each cpufreq_cooling_device |
| * registered. |
| * @cool_dev: thermal_cooling_device pointer to keep track of the the |
| * egistered cooling device. |
| * @cpufreq_state: integer value representing the current state of cpufreq |
| * cooling devices. |
| * @cpufreq_val: integer value representing the absolute value of the clipped |
| * frequency. |
| * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device. |
| * @node: list_head to link all cpufreq_cooling_device together. |
| * |
| * This structure is required for keeping information of each |
| * cpufreq_cooling_device registered as a list whose head is represented by |
| * cooling_cpufreq_list. In order to prevent corruption of this list a |
| * mutex lock cooling_cpufreq_lock is used. |
| */ |
| struct cpufreq_cooling_device { |
| int id; |
| struct thermal_cooling_device *cool_dev; |
| unsigned int cpufreq_state; |
| unsigned int cpufreq_val; |
| struct cpumask allowed_cpus; |
| struct list_head node; |
| }; |
| static LIST_HEAD(cooling_cpufreq_list); |
| static DEFINE_IDR(cpufreq_idr); |
| |
| static struct mutex cooling_cpufreq_lock; |
| |
| /* notify_table passes value to the CPUFREQ_ADJUST callback function. */ |
| #define NOTIFY_INVALID NULL |
| struct cpufreq_cooling_device *notify_device; |
| |
| /** |
| * get_idr - function to get a unique id. |
| * @idr: struct idr * handle used to create a id. |
| * @id: int * value generated by this function. |
| */ |
| static int get_idr(struct idr *idr, int *id) |
| { |
| int err; |
| again: |
| if (unlikely(idr_pre_get(idr, GFP_KERNEL) == 0)) |
| return -ENOMEM; |
| |
| mutex_lock(&cooling_cpufreq_lock); |
| err = idr_get_new(idr, NULL, id); |
| mutex_unlock(&cooling_cpufreq_lock); |
| |
| if (unlikely(err == -EAGAIN)) |
| goto again; |
| else if (unlikely(err)) |
| return err; |
| |
| *id = *id & MAX_IDR_MASK; |
| return 0; |
| } |
| |
| /** |
| * release_idr - function to free the unique id. |
| * @idr: struct idr * handle used for creating the id. |
| * @id: int value representing the unique id. |
| */ |
| static void release_idr(struct idr *idr, int id) |
| { |
| mutex_lock(&cooling_cpufreq_lock); |
| idr_remove(idr, id); |
| mutex_unlock(&cooling_cpufreq_lock); |
| } |
| |
| /* Below code defines functions to be used for cpufreq as cooling device */ |
| |
| /** |
| * is_cpufreq_valid - function to check if a cpu has frequency transition policy. |
| * @cpu: cpu for which check is needed. |
| */ |
| static int is_cpufreq_valid(int cpu) |
| { |
| struct cpufreq_policy policy; |
| return !cpufreq_get_policy(&policy, cpu); |
| } |
| |
| /** |
| * get_cpu_frequency - get the absolute value of frequency from level. |
| * @cpu: cpu for which frequency is fetched. |
| * @level: level of frequency of the CPU |
| * e.g level=1 --> 1st MAX FREQ, LEVEL=2 ---> 2nd MAX FREQ, .... etc |
| */ |
| static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level) |
| { |
| int ret = 0, i = 0; |
| unsigned long level_index; |
| bool descend = false; |
| struct cpufreq_frequency_table *table = |
| cpufreq_frequency_get_table(cpu); |
| if (!table) |
| return ret; |
| |
| while (table[i].frequency != CPUFREQ_TABLE_END) { |
| if (table[i].frequency == CPUFREQ_ENTRY_INVALID) |
| continue; |
| |
| /*check if table in ascending or descending order*/ |
| if ((table[i + 1].frequency != CPUFREQ_TABLE_END) && |
| (table[i + 1].frequency < table[i].frequency) |
| && !descend) { |
| descend = true; |
| } |
| |
| /*return if level matched and table in descending order*/ |
| if (descend && i == level) |
| return table[i].frequency; |
| i++; |
| } |
| i--; |
| |
| if (level > i || descend) |
| return ret; |
| level_index = i - level; |
| |
| /*Scan the table in reverse order and match the level*/ |
| while (i >= 0) { |
| if (table[i].frequency == CPUFREQ_ENTRY_INVALID) |
| continue; |
| /*return if level matched*/ |
| if (i == level_index) |
| return table[i].frequency; |
| i--; |
| } |
| return ret; |
| } |
| |
| /** |
| * cpufreq_apply_cooling - function to apply frequency clipping. |
| * @cpufreq_device: cpufreq_cooling_device pointer containing frequency |
| * clipping data. |
| * @cooling_state: value of the cooling state. |
| */ |
| static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device, |
| unsigned long cooling_state) |
| { |
| unsigned int cpuid, clip_freq; |
| struct cpumask *maskPtr = &cpufreq_device->allowed_cpus; |
| unsigned int cpu = cpumask_any(maskPtr); |
| |
| |
| /* Check if the old cooling action is same as new cooling action */ |
| if (cpufreq_device->cpufreq_state == cooling_state) |
| return 0; |
| |
| clip_freq = get_cpu_frequency(cpu, cooling_state); |
| if (!clip_freq) |
| return -EINVAL; |
| |
| cpufreq_device->cpufreq_state = cooling_state; |
| cpufreq_device->cpufreq_val = clip_freq; |
| notify_device = cpufreq_device; |
| |
| for_each_cpu(cpuid, maskPtr) { |
| if (is_cpufreq_valid(cpuid)) |
| cpufreq_update_policy(cpuid); |
| } |
| |
| notify_device = NOTIFY_INVALID; |
| |
| return 0; |
| } |
| |
| /** |
| * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. |
| * @nb: struct notifier_block * with callback info. |
| * @event: value showing cpufreq event for which this function invoked. |
| * @data: callback-specific data |
| */ |
| static int cpufreq_thermal_notifier(struct notifier_block *nb, |
| unsigned long event, void *data) |
| { |
| struct cpufreq_policy *policy = data; |
| unsigned long max_freq = 0; |
| |
| if (event != CPUFREQ_ADJUST || notify_device == NOTIFY_INVALID) |
| return 0; |
| |
| if (cpumask_test_cpu(policy->cpu, ¬ify_device->allowed_cpus)) |
| max_freq = notify_device->cpufreq_val; |
| |
| /* Never exceed user_policy.max*/ |
| if (max_freq > policy->user_policy.max) |
| max_freq = policy->user_policy.max; |
| |
| if (policy->max != max_freq) |
| cpufreq_verify_within_limits(policy, 0, max_freq); |
| |
| return 0; |
| } |
| |
| /* |
| * cpufreq cooling device callback functions are defined below |
| */ |
| |
| /** |
| * cpufreq_get_max_state - callback function to get the max cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: fill this variable with the max cooling state. |
| */ |
| static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, |
| unsigned long *state) |
| { |
| int ret = -EINVAL, i = 0; |
| struct cpufreq_cooling_device *cpufreq_device; |
| struct cpumask *maskPtr; |
| unsigned int cpu; |
| struct cpufreq_frequency_table *table; |
| |
| mutex_lock(&cooling_cpufreq_lock); |
| list_for_each_entry(cpufreq_device, &cooling_cpufreq_list, node) { |
| if (cpufreq_device && cpufreq_device->cool_dev == cdev) |
| break; |
| } |
| if (cpufreq_device == NULL) |
| goto return_get_max_state; |
| |
| maskPtr = &cpufreq_device->allowed_cpus; |
| cpu = cpumask_any(maskPtr); |
| table = cpufreq_frequency_get_table(cpu); |
| if (!table) { |
| *state = 0; |
| ret = 0; |
| goto return_get_max_state; |
| } |
| |
| while (table[i].frequency != CPUFREQ_TABLE_END) { |
| if (table[i].frequency == CPUFREQ_ENTRY_INVALID) |
| continue; |
| i++; |
| } |
| if (i > 0) { |
| *state = --i; |
| ret = 0; |
| } |
| |
| return_get_max_state: |
| mutex_unlock(&cooling_cpufreq_lock); |
| return ret; |
| } |
| |
| /** |
| * cpufreq_get_cur_state - callback function to get the current cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: fill this variable with the current cooling state. |
| */ |
| static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, |
| unsigned long *state) |
| { |
| int ret = -EINVAL; |
| struct cpufreq_cooling_device *cpufreq_device; |
| |
| mutex_lock(&cooling_cpufreq_lock); |
| list_for_each_entry(cpufreq_device, &cooling_cpufreq_list, node) { |
| if (cpufreq_device && cpufreq_device->cool_dev == cdev) { |
| *state = cpufreq_device->cpufreq_state; |
| ret = 0; |
| break; |
| } |
| } |
| mutex_unlock(&cooling_cpufreq_lock); |
| |
| return ret; |
| } |
| |
| /** |
| * cpufreq_set_cur_state - callback function to set the current cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: set this variable to the current cooling state. |
| */ |
| static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, |
| unsigned long state) |
| { |
| int ret = -EINVAL; |
| struct cpufreq_cooling_device *cpufreq_device; |
| |
| mutex_lock(&cooling_cpufreq_lock); |
| list_for_each_entry(cpufreq_device, &cooling_cpufreq_list, node) { |
| if (cpufreq_device && cpufreq_device->cool_dev == cdev) { |
| ret = 0; |
| break; |
| } |
| } |
| if (!ret) |
| ret = cpufreq_apply_cooling(cpufreq_device, state); |
| |
| mutex_unlock(&cooling_cpufreq_lock); |
| |
| return ret; |
| } |
| |
| /* Bind cpufreq callbacks to thermal cooling device ops */ |
| static struct thermal_cooling_device_ops const cpufreq_cooling_ops = { |
| .get_max_state = cpufreq_get_max_state, |
| .get_cur_state = cpufreq_get_cur_state, |
| .set_cur_state = cpufreq_set_cur_state, |
| }; |
| |
| /* Notifier for cpufreq policy change */ |
| static struct notifier_block thermal_cpufreq_notifier_block = { |
| .notifier_call = cpufreq_thermal_notifier, |
| }; |
| |
| /** |
| * cpufreq_cooling_register - function to create cpufreq cooling device. |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen. |
| */ |
| struct thermal_cooling_device *cpufreq_cooling_register( |
| struct cpumask *clip_cpus) |
| { |
| struct thermal_cooling_device *cool_dev; |
| struct cpufreq_cooling_device *cpufreq_dev = NULL; |
| unsigned int cpufreq_dev_count = 0, min = 0, max = 0; |
| char dev_name[THERMAL_NAME_LENGTH]; |
| int ret = 0, i; |
| struct cpufreq_policy policy; |
| |
| list_for_each_entry(cpufreq_dev, &cooling_cpufreq_list, node) |
| cpufreq_dev_count++; |
| |
| /*Verify that all the clip cpus have same freq_min, freq_max limit*/ |
| for_each_cpu(i, clip_cpus) { |
| /*continue if cpufreq policy not found and not return error*/ |
| if (!cpufreq_get_policy(&policy, i)) |
| continue; |
| if (min == 0 && max == 0) { |
| min = policy.cpuinfo.min_freq; |
| max = policy.cpuinfo.max_freq; |
| } else { |
| if (min != policy.cpuinfo.min_freq || |
| max != policy.cpuinfo.max_freq) |
| return ERR_PTR(-EINVAL); |
| } |
| } |
| cpufreq_dev = kzalloc(sizeof(struct cpufreq_cooling_device), |
| GFP_KERNEL); |
| if (!cpufreq_dev) |
| return ERR_PTR(-ENOMEM); |
| |
| cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus); |
| |
| if (cpufreq_dev_count == 0) |
| mutex_init(&cooling_cpufreq_lock); |
| |
| ret = get_idr(&cpufreq_idr, &cpufreq_dev->id); |
| if (ret) { |
| kfree(cpufreq_dev); |
| return ERR_PTR(-EINVAL); |
| } |
| |
| sprintf(dev_name, "thermal-cpufreq-%d", cpufreq_dev->id); |
| |
| cool_dev = thermal_cooling_device_register(dev_name, cpufreq_dev, |
| &cpufreq_cooling_ops); |
| if (!cool_dev) { |
| release_idr(&cpufreq_idr, cpufreq_dev->id); |
| kfree(cpufreq_dev); |
| return ERR_PTR(-EINVAL); |
| } |
| cpufreq_dev->cool_dev = cool_dev; |
| cpufreq_dev->cpufreq_state = 0; |
| mutex_lock(&cooling_cpufreq_lock); |
| list_add_tail(&cpufreq_dev->node, &cooling_cpufreq_list); |
| |
| /* Register the notifier for first cpufreq cooling device */ |
| if (cpufreq_dev_count == 0) |
| cpufreq_register_notifier(&thermal_cpufreq_notifier_block, |
| CPUFREQ_POLICY_NOTIFIER); |
| |
| mutex_unlock(&cooling_cpufreq_lock); |
| return cool_dev; |
| } |
| EXPORT_SYMBOL(cpufreq_cooling_register); |
| |
| /** |
| * cpufreq_cooling_unregister - function to remove cpufreq cooling device. |
| * @cdev: thermal cooling device pointer. |
| */ |
| void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) |
| { |
| struct cpufreq_cooling_device *cpufreq_dev = NULL; |
| unsigned int cpufreq_dev_count = 0; |
| |
| mutex_lock(&cooling_cpufreq_lock); |
| list_for_each_entry(cpufreq_dev, &cooling_cpufreq_list, node) { |
| if (cpufreq_dev && cpufreq_dev->cool_dev == cdev) |
| break; |
| cpufreq_dev_count++; |
| } |
| |
| if (!cpufreq_dev || cpufreq_dev->cool_dev != cdev) { |
| mutex_unlock(&cooling_cpufreq_lock); |
| return; |
| } |
| |
| list_del(&cpufreq_dev->node); |
| |
| /* Unregister the notifier for the last cpufreq cooling device */ |
| if (cpufreq_dev_count == 1) { |
| cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block, |
| CPUFREQ_POLICY_NOTIFIER); |
| } |
| mutex_unlock(&cooling_cpufreq_lock); |
| thermal_cooling_device_unregister(cpufreq_dev->cool_dev); |
| release_idr(&cpufreq_idr, cpufreq_dev->id); |
| if (cpufreq_dev_count == 1) |
| mutex_destroy(&cooling_cpufreq_lock); |
| kfree(cpufreq_dev); |
| } |
| EXPORT_SYMBOL(cpufreq_cooling_unregister); |