blob: d0cb8693963b51f447afbb9b6e6c5bd42e87f34e [file] [log] [blame]
* Marvell Armada 370 / Armada XP Ethernet Controller (NETA)
Required properties:
- compatible: "marvell,armada-370-neta" or "marvell,armada-xp-neta".
- reg: address and length of the register set for the device.
- interrupts: interrupt for the device
- phy: See ethernet.txt file in the same directory.
- phy-mode: See ethernet.txt file in the same directory
- clocks: List of clocks for this device. At least one clock is
mandatory for the core clock. If several clocks are given, then the
clock-names property must be used to identify them.
Optional properties:
- tx-csum-limit: maximum mtu supported by port that allow TX checksum.
Value is presented in bytes. If not used, by default 1600B is set for
"marvell,armada-370-neta" and 9800B for others.
- clock-names: List of names corresponding to clocks property; shall be
"core" for core clock and "bus" for the optional bus clock.
Example:
ethernet@d0070000 {
compatible = "marvell,armada-370-neta";
reg = <0xd0070000 0x2500>;
interrupts = <8>;
clocks = <&gate_clk 4>;
tx-csum-limit = <9800>
status = "okay";
phy = <&phy0>;
phy-mode = "rgmii-id";
};