| * linux/drivers/thermal/cpu_cooling.c |
| * |
| * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) |
| * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org> |
| * |
| * Copyright (C) 2014 Viresh Kumar <viresh.kumar@linaro.org> |
| * |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| * This program is free software; you can redistribute it and/or modify |
| * it under the terms of the GNU General Public License as published by |
| * the Free Software Foundation; version 2 of the License. |
| * |
| * This program is distributed in the hope that it will be useful, but |
| * WITHOUT ANY WARRANTY; without even the implied warranty of |
| * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU |
| * General Public License for more details. |
| * |
| * You should have received a copy of the GNU General Public License along |
| * with this program; if not, write to the Free Software Foundation, Inc., |
| * 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA. |
| * |
| * ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| */ |
| #include <linux/module.h> |
| #include <linux/thermal.h> |
| #include <linux/cpufreq.h> |
| #include <linux/err.h> |
| #include <linux/pm_opp.h> |
| #include <linux/slab.h> |
| #include <linux/cpu.h> |
| #include <linux/cpu_cooling.h> |
| #include <linux/sched.h> |
| #include <linux/of_device.h> |
| #include <linux/suspend.h> |
| |
| #include <trace/events/thermal.h> |
| |
| /* |
| * Cooling state <-> CPUFreq frequency |
| * |
| * Cooling states are translated to frequencies throughout this driver and this |
| * is the relation between them. |
| * |
| * Highest cooling state corresponds to lowest possible frequency. |
| * |
| * i.e. |
| * level 0 --> 1st Max Freq |
| * level 1 --> 2nd Max Freq |
| * ... |
| * leven n --> core isolated |
| */ |
| |
| /** |
| * struct power_table - frequency to power conversion |
| * @frequency: frequency in KHz |
| * @power: power in mW |
| * |
| * This structure is built when the cooling device registers and helps |
| * in translating frequency to power and viceversa. |
| */ |
| struct power_table { |
| u32 frequency; |
| u32 power; |
| }; |
| |
| /** |
| * struct cpufreq_cooling_device - data for cooling device with cpufreq |
| * @id: unique integer value corresponding to each cpufreq_cooling_device |
| * registered. |
| * @cool_dev: thermal_cooling_device pointer to keep track of the |
| * registered cooling device. |
| * @cpufreq_state: integer value representing the current state of cpufreq |
| * cooling devices. |
| * @clipped_freq: integer value representing the absolute value of the clipped |
| * frequency. |
| * @cpufreq_floor_state: integer value representing the frequency floor state |
| * of cpufreq cooling devices. |
| * @floor_freq: integer value representing the absolute value of the floor |
| * frequency. |
| * @max_level: maximum cooling level. [0..max_level-1: <freq> |
| * max_level: Core unavailable] |
| * @allowed_cpus: all the cpus involved for this cpufreq_cooling_device. |
| * @node: list_head to link all cpufreq_cooling_device together. |
| * @last_load: load measured by the latest call to cpufreq_get_requested_power() |
| * @time_in_idle: previous reading of the absolute time that this cpu was idle |
| * @time_in_idle_timestamp: wall time of the last invocation of |
| * get_cpu_idle_time_us() |
| * @dyn_power_table: array of struct power_table for frequency to power |
| * conversion, sorted in ascending order. |
| * @dyn_power_table_entries: number of entries in the @dyn_power_table array |
| * @cpu_dev: the first cpu_device from @allowed_cpus that has OPPs registered |
| * @plat_get_static_power: callback to calculate the static power |
| * |
| * This structure is required for keeping information of each registered |
| * cpufreq_cooling_device. |
| */ |
| struct cpufreq_cooling_device { |
| int id; |
| struct thermal_cooling_device *cool_dev; |
| unsigned int cpufreq_state; |
| unsigned int clipped_freq; |
| unsigned int cpufreq_floor_state; |
| unsigned int floor_freq; |
| unsigned int max_level; |
| unsigned int *freq_table; /* In descending order */ |
| struct cpumask allowed_cpus; |
| struct cpufreq_policy *policy; |
| struct list_head node; |
| u32 last_load; |
| u64 *time_in_idle; |
| u64 *time_in_idle_timestamp; |
| struct power_table *dyn_power_table; |
| int dyn_power_table_entries; |
| struct device *cpu_dev; |
| get_static_t plat_get_static_power; |
| struct cpu_cooling_ops *plat_ops; |
| }; |
| static DEFINE_IDR(cpufreq_idr); |
| static DEFINE_MUTEX(cooling_cpufreq_lock); |
| |
| static atomic_t in_suspend; |
| static unsigned int cpufreq_dev_count; |
| static int8_t cpuhp_registered; |
| static struct work_struct cpuhp_register_work; |
| static struct cpumask cpus_pending_online; |
| static struct cpumask cpus_isolated_by_thermal; |
| static DEFINE_MUTEX(core_isolate_lock); |
| |
| static DEFINE_MUTEX(cooling_list_lock); |
| static LIST_HEAD(cpufreq_dev_list); |
| |
| /** |
| * get_idr - function to get a unique id. |
| * @idr: struct idr * handle used to create a id. |
| * @id: int * value generated by this function. |
| * |
| * This function will populate @id with an unique |
| * id, using the idr API. |
| * |
| * Return: 0 on success, an error code on failure. |
| */ |
| static int get_idr(struct idr *idr, int *id) |
| { |
| int ret; |
| |
| mutex_lock(&cooling_cpufreq_lock); |
| ret = idr_alloc(idr, NULL, 0, 0, GFP_KERNEL); |
| mutex_unlock(&cooling_cpufreq_lock); |
| if (unlikely(ret < 0)) |
| return ret; |
| *id = ret; |
| |
| return 0; |
| } |
| |
| /** |
| * release_idr - function to free the unique id. |
| * @idr: struct idr * handle used for creating the id. |
| * @id: int value representing the unique id. |
| */ |
| static void release_idr(struct idr *idr, int id) |
| { |
| mutex_lock(&cooling_cpufreq_lock); |
| idr_remove(idr, id); |
| mutex_unlock(&cooling_cpufreq_lock); |
| } |
| |
| /* Below code defines functions to be used for cpufreq as cooling device */ |
| |
| /** |
| * get_level: Find the level for a particular frequency |
| * @cpufreq_dev: cpufreq_dev for which the property is required |
| * @freq: Frequency |
| * |
| * Return: level on success, THERMAL_CSTATE_INVALID on error. |
| */ |
| static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_dev, |
| unsigned int freq) |
| { |
| unsigned long level; |
| |
| for (level = 0; level < cpufreq_dev->max_level; level++) { |
| if (freq == cpufreq_dev->freq_table[level]) |
| return level; |
| |
| if (freq > cpufreq_dev->freq_table[level]) |
| break; |
| } |
| |
| return THERMAL_CSTATE_INVALID; |
| } |
| |
| /** |
| * cpufreq_cooling_get_level - for a given cpu, return the cooling level. |
| * @cpu: cpu for which the level is required |
| * @freq: the frequency of interest |
| * |
| * This function will match the cooling level corresponding to the |
| * requested @freq and return it. |
| * |
| * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID |
| * otherwise. |
| */ |
| unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) |
| { |
| struct cpufreq_cooling_device *cpufreq_dev; |
| |
| mutex_lock(&cooling_list_lock); |
| list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { |
| if (cpumask_test_cpu(cpu, &cpufreq_dev->allowed_cpus)) { |
| unsigned long level = get_level(cpufreq_dev, freq); |
| |
| mutex_unlock(&cooling_list_lock); |
| return level; |
| } |
| } |
| mutex_unlock(&cooling_list_lock); |
| |
| pr_err("%s: cpu:%d not part of any cooling device\n", __func__, cpu); |
| return THERMAL_CSTATE_INVALID; |
| } |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level); |
| |
| static int cpufreq_cooling_pm_notify(struct notifier_block *nb, |
| unsigned long mode, void *_unused) |
| { |
| struct cpufreq_cooling_device *cpufreq_dev, *next; |
| unsigned int cpu; |
| |
| switch (mode) { |
| case PM_HIBERNATION_PREPARE: |
| case PM_RESTORE_PREPARE: |
| case PM_SUSPEND_PREPARE: |
| atomic_set(&in_suspend, 1); |
| break; |
| case PM_POST_HIBERNATION: |
| case PM_POST_RESTORE: |
| case PM_POST_SUSPEND: |
| list_for_each_entry_safe(cpufreq_dev, next, &cpufreq_dev_list, |
| node) { |
| mutex_lock(&core_isolate_lock); |
| if (cpufreq_dev->cpufreq_state == |
| cpufreq_dev->max_level) { |
| cpu = cpumask_any(&cpufreq_dev->allowed_cpus); |
| /* |
| * Unlock this lock before calling |
| * schedule_isolate. as this could lead to |
| * deadlock with hotplug path. |
| */ |
| mutex_unlock(&core_isolate_lock); |
| if (cpu_online(cpu) && |
| !cpumask_test_and_set_cpu(cpu, |
| &cpus_isolated_by_thermal)) { |
| if (sched_isolate_cpu(cpu)) |
| cpumask_clear_cpu(cpu, |
| &cpus_isolated_by_thermal); |
| } |
| continue; |
| } |
| mutex_unlock(&core_isolate_lock); |
| } |
| |
| atomic_set(&in_suspend, 0); |
| break; |
| default: |
| break; |
| } |
| return 0; |
| } |
| |
| static struct notifier_block cpufreq_cooling_pm_nb = { |
| .notifier_call = cpufreq_cooling_pm_notify, |
| }; |
| |
| static int cpufreq_hp_offline(unsigned int offline_cpu) |
| { |
| struct cpufreq_cooling_device *cpufreq_dev; |
| |
| mutex_lock(&cooling_list_lock); |
| list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { |
| if (!cpumask_test_cpu(offline_cpu, &cpufreq_dev->allowed_cpus)) |
| continue; |
| |
| mutex_lock(&core_isolate_lock); |
| if ((cpufreq_dev->cpufreq_state == cpufreq_dev->max_level) && |
| (cpumask_test_and_clear_cpu(offline_cpu, |
| &cpus_isolated_by_thermal))) |
| sched_unisolate_cpu_unlocked(offline_cpu); |
| mutex_unlock(&core_isolate_lock); |
| break; |
| } |
| mutex_unlock(&cooling_list_lock); |
| |
| return 0; |
| } |
| |
| static int cpufreq_hp_online(unsigned int online_cpu) |
| { |
| struct cpufreq_cooling_device *cpufreq_dev; |
| int ret = 0; |
| |
| if (atomic_read(&in_suspend)) |
| return 0; |
| |
| mutex_lock(&cooling_list_lock); |
| list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { |
| if (!cpumask_test_cpu(online_cpu, &cpufreq_dev->allowed_cpus)) |
| continue; |
| |
| mutex_lock(&core_isolate_lock); |
| if (cpufreq_dev->cpufreq_state == cpufreq_dev->max_level) { |
| cpumask_set_cpu(online_cpu, &cpus_pending_online); |
| ret = NOTIFY_BAD; |
| } |
| mutex_unlock(&core_isolate_lock); |
| break; |
| } |
| mutex_unlock(&cooling_list_lock); |
| |
| return ret; |
| } |
| |
| /** |
| * cpufreq_thermal_notifier - notifier callback for cpufreq policy change. |
| * @nb: struct notifier_block * with callback info. |
| * @event: value showing cpufreq event for which this function invoked. |
| * @data: callback-specific data |
| * |
| * Callback to hijack the notification on cpufreq policy transition. |
| * Every time there is a change in policy, we will intercept and |
| * update the cpufreq policy with thermal constraints. |
| * |
| * Return: 0 (success) |
| */ |
| static int cpufreq_thermal_notifier(struct notifier_block *nb, |
| unsigned long event, void *data) |
| { |
| struct cpufreq_policy *policy = data; |
| unsigned long clipped_freq = ULONG_MAX, floor_freq = 0; |
| struct cpufreq_cooling_device *cpufreq_dev; |
| |
| if (event != CPUFREQ_INCOMPATIBLE) |
| return NOTIFY_DONE; |
| |
| mutex_lock(&cooling_list_lock); |
| list_for_each_entry(cpufreq_dev, &cpufreq_dev_list, node) { |
| if (!cpumask_intersects(&cpufreq_dev->allowed_cpus, |
| policy->related_cpus)) |
| continue; |
| if (cpufreq_dev->clipped_freq < clipped_freq) |
| clipped_freq = cpufreq_dev->clipped_freq; |
| if (cpufreq_dev->floor_freq > floor_freq) |
| floor_freq = cpufreq_dev->floor_freq; |
| } |
| /* |
| * policy->max is the maximum allowed frequency defined by user |
| * and clipped_freq is the maximum that thermal constraints |
| * allow. |
| * |
| * If clipped_freq is lower than policy->max, then we need to |
| * readjust policy->max. |
| * |
| * But, if clipped_freq is greater than policy->max, we don't |
| * need to do anything. |
| * |
| * Similarly, if policy minimum set by the user is less than |
| * the floor_frequency, then adjust the policy->min. |
| */ |
| if (policy->max > clipped_freq || policy->min < floor_freq) |
| cpufreq_verify_within_limits(policy, floor_freq, clipped_freq); |
| mutex_unlock(&cooling_list_lock); |
| |
| return NOTIFY_OK; |
| } |
| |
| /** |
| * build_dyn_power_table() - create a dynamic power to frequency table |
| * @cpufreq_device: the cpufreq cooling device in which to store the table |
| * @capacitance: dynamic power coefficient for these cpus |
| * |
| * Build a dynamic power to frequency table for this cpu and store it |
| * in @cpufreq_device. This table will be used in cpu_power_to_freq() and |
| * cpu_freq_to_power() to convert between power and frequency |
| * efficiently. Power is stored in mW, frequency in KHz. The |
| * resulting table is in ascending order. |
| * |
| * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs, |
| * -ENOMEM if we run out of memory or -EAGAIN if an OPP was |
| * added/enabled while the function was executing. |
| */ |
| static int build_dyn_power_table(struct cpufreq_cooling_device *cpufreq_device, |
| u32 capacitance) |
| { |
| struct power_table *power_table; |
| struct dev_pm_opp *opp; |
| struct device *dev = NULL; |
| int num_opps = 0, cpu, i, ret = 0; |
| unsigned long freq; |
| |
| for_each_cpu(cpu, &cpufreq_device->allowed_cpus) { |
| dev = get_cpu_device(cpu); |
| if (!dev) { |
| dev_warn(&cpufreq_device->cool_dev->device, |
| "No cpu device for cpu %d\n", cpu); |
| continue; |
| } |
| |
| num_opps = dev_pm_opp_get_opp_count(dev); |
| if (num_opps > 0) |
| break; |
| else if (num_opps < 0) |
| return num_opps; |
| } |
| |
| if (num_opps == 0) |
| return -EINVAL; |
| |
| power_table = kcalloc(num_opps, sizeof(*power_table), GFP_KERNEL); |
| if (!power_table) |
| return -ENOMEM; |
| |
| rcu_read_lock(); |
| |
| for (freq = 0, i = 0; |
| opp = dev_pm_opp_find_freq_ceil(dev, &freq), !IS_ERR(opp); |
| freq++, i++) { |
| u32 freq_mhz, voltage_mv; |
| u64 power; |
| |
| if (i >= num_opps) { |
| rcu_read_unlock(); |
| ret = -EAGAIN; |
| goto free_power_table; |
| } |
| |
| freq_mhz = freq / 1000000; |
| voltage_mv = dev_pm_opp_get_voltage(opp) / 1000; |
| |
| /* |
| * Do the multiplication with MHz and millivolt so as |
| * to not overflow. |
| */ |
| power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv; |
| do_div(power, 1000000000); |
| |
| /* frequency is stored in power_table in KHz */ |
| power_table[i].frequency = freq / 1000; |
| |
| /* power is stored in mW */ |
| power_table[i].power = power; |
| } |
| |
| rcu_read_unlock(); |
| |
| if (i != num_opps) { |
| ret = PTR_ERR(opp); |
| goto free_power_table; |
| } |
| |
| cpufreq_device->cpu_dev = dev; |
| cpufreq_device->dyn_power_table = power_table; |
| cpufreq_device->dyn_power_table_entries = i; |
| |
| return 0; |
| |
| free_power_table: |
| kfree(power_table); |
| |
| return ret; |
| } |
| |
| static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_device, |
| u32 freq) |
| { |
| int i; |
| struct power_table *pt = cpufreq_device->dyn_power_table; |
| |
| for (i = 1; i < cpufreq_device->dyn_power_table_entries; i++) |
| if (freq < pt[i].frequency) |
| break; |
| |
| return pt[i - 1].power; |
| } |
| |
| static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_device, |
| u32 power) |
| { |
| int i; |
| struct power_table *pt = cpufreq_device->dyn_power_table; |
| |
| for (i = 1; i < cpufreq_device->dyn_power_table_entries; i++) |
| if (power < pt[i].power) |
| break; |
| |
| return pt[i - 1].frequency; |
| } |
| |
| /** |
| * get_load() - get load for a cpu since last updated |
| * @cpufreq_device: &struct cpufreq_cooling_device for this cpu |
| * @cpu: cpu number |
| * @cpu_idx: index of the cpu in cpufreq_device->allowed_cpus |
| * |
| * Return: The average load of cpu @cpu in percentage since this |
| * function was last called. |
| */ |
| static u32 get_load(struct cpufreq_cooling_device *cpufreq_device, int cpu, |
| int cpu_idx) |
| { |
| u32 load; |
| u64 now, now_idle, delta_time, delta_idle; |
| |
| now_idle = get_cpu_idle_time(cpu, &now, 0); |
| delta_idle = now_idle - cpufreq_device->time_in_idle[cpu_idx]; |
| delta_time = now - cpufreq_device->time_in_idle_timestamp[cpu_idx]; |
| |
| if (delta_time <= delta_idle) |
| load = 0; |
| else |
| load = div64_u64(100 * (delta_time - delta_idle), delta_time); |
| |
| cpufreq_device->time_in_idle[cpu_idx] = now_idle; |
| cpufreq_device->time_in_idle_timestamp[cpu_idx] = now; |
| |
| return load; |
| } |
| |
| /** |
| * get_static_power() - calculate the static power consumed by the cpus |
| * @cpufreq_device: struct &cpufreq_cooling_device for this cpu cdev |
| * @tz: thermal zone device in which we're operating |
| * @freq: frequency in KHz |
| * @power: pointer in which to store the calculated static power |
| * |
| * Calculate the static power consumed by the cpus described by |
| * @cpu_actor running at frequency @freq. This function relies on a |
| * platform specific function that should have been provided when the |
| * actor was registered. If it wasn't, the static power is assumed to |
| * be negligible. The calculated static power is stored in @power. |
| * |
| * Return: 0 on success, -E* on failure. |
| */ |
| static int get_static_power(struct cpufreq_cooling_device *cpufreq_device, |
| struct thermal_zone_device *tz, unsigned long freq, |
| u32 *power) |
| { |
| struct dev_pm_opp *opp; |
| unsigned long voltage; |
| struct cpumask *cpumask = &cpufreq_device->allowed_cpus; |
| unsigned long freq_hz = freq * 1000; |
| |
| if (!cpufreq_device->plat_get_static_power || |
| !cpufreq_device->cpu_dev) { |
| *power = 0; |
| return 0; |
| } |
| |
| rcu_read_lock(); |
| |
| opp = dev_pm_opp_find_freq_exact(cpufreq_device->cpu_dev, freq_hz, |
| true); |
| voltage = dev_pm_opp_get_voltage(opp); |
| |
| rcu_read_unlock(); |
| |
| if (voltage == 0) { |
| dev_warn_ratelimited(cpufreq_device->cpu_dev, |
| "Failed to get voltage for frequency %lu: %ld\n", |
| freq_hz, IS_ERR(opp) ? PTR_ERR(opp) : 0); |
| return -EINVAL; |
| } |
| |
| return cpufreq_device->plat_get_static_power(cpumask, tz->passive_delay, |
| voltage, power); |
| } |
| |
| /** |
| * get_dynamic_power() - calculate the dynamic power |
| * @cpufreq_device: &cpufreq_cooling_device for this cdev |
| * @freq: current frequency |
| * |
| * Return: the dynamic power consumed by the cpus described by |
| * @cpufreq_device. |
| */ |
| static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_device, |
| unsigned long freq) |
| { |
| u32 raw_cpu_power; |
| |
| raw_cpu_power = cpu_freq_to_power(cpufreq_device, freq); |
| return (raw_cpu_power * cpufreq_device->last_load) / 100; |
| } |
| |
| /* cpufreq cooling device callback functions are defined below */ |
| |
| /** |
| * cpufreq_get_max_state - callback function to get the max cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: fill this variable with the max cooling state. |
| * |
| * Callback for the thermal cooling device to return the cpufreq |
| * max cooling state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_get_max_state(struct thermal_cooling_device *cdev, |
| unsigned long *state) |
| { |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| |
| *state = cpufreq_device->max_level; |
| return 0; |
| } |
| |
| /** |
| * cpufreq_get_min_state - callback function to get the device floor state. |
| * @cdev: thermal cooling device pointer. |
| * @state: fill this variable with the cooling device floor. |
| * |
| * Callback for the thermal cooling device to return the cpufreq |
| * floor state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_get_min_state(struct thermal_cooling_device *cdev, |
| unsigned long *state) |
| { |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| |
| *state = cpufreq_device->cpufreq_floor_state; |
| |
| return 0; |
| } |
| |
| /** |
| * cpufreq_set_min_state - callback function to set the device floor state. |
| * @cdev: thermal cooling device pointer. |
| * @state: set this variable to the current cooling state. |
| * |
| * Callback for the thermal cooling device to change the cpufreq |
| * floor state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_set_min_state(struct thermal_cooling_device *cdev, |
| unsigned long state) |
| { |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus); |
| struct cpumask policy_online_cpus; |
| unsigned int floor_freq; |
| |
| if (state > cpufreq_device->max_level) |
| state = cpufreq_device->max_level; |
| |
| if (cpufreq_device->cpufreq_floor_state == state) |
| return 0; |
| |
| cpufreq_device->cpufreq_floor_state = state; |
| |
| /* |
| * Check if the device has a platform mitigation function that |
| * can handle the CPU freq mitigation, if not, notify cpufreq |
| * framework. |
| */ |
| if (cpufreq_device->plat_ops && |
| cpufreq_device->plat_ops->floor_limit) { |
| /* |
| * Last level is core isolation so use the frequency |
| * of previous state. |
| */ |
| if (state == cpufreq_device->max_level) |
| state--; |
| floor_freq = cpufreq_device->freq_table[state]; |
| cpufreq_device->floor_freq = floor_freq; |
| cpufreq_device->plat_ops->floor_limit(cpu, floor_freq); |
| } else { |
| floor_freq = cpufreq_device->freq_table[state]; |
| cpufreq_device->floor_freq = floor_freq; |
| if (cpumask_and(&policy_online_cpus, cpu_online_mask, |
| cpufreq_device->policy->related_cpus)) |
| cpufreq_update_policy(cpumask_first( |
| &policy_online_cpus)); |
| } |
| |
| return 0; |
| } |
| |
| /** |
| * cpufreq_get_cur_state - callback function to get the current cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: fill this variable with the current cooling state. |
| * |
| * Callback for the thermal cooling device to return the cpufreq |
| * current cooling state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev, |
| unsigned long *state) |
| { |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| |
| *state = cpufreq_device->cpufreq_state; |
| |
| return 0; |
| } |
| |
| /** |
| * cpufreq_set_cur_state - callback function to set the current cooling state. |
| * @cdev: thermal cooling device pointer. |
| * @state: set this variable to the current cooling state. |
| * |
| * Callback for the thermal cooling device to change the cpufreq |
| * current cooling state. |
| * |
| * Return: 0 on success, an error code otherwise. |
| */ |
| static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, |
| unsigned long state) |
| { |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| unsigned int cpu = cpumask_any(&cpufreq_device->allowed_cpus); |
| struct cpumask policy_online_cpus; |
| unsigned int clip_freq; |
| unsigned long prev_state; |
| struct device *cpu_dev; |
| int ret = 0; |
| |
| /* Request state should be less than max_level */ |
| if (WARN_ON(state > cpufreq_device->max_level)) |
| return -EINVAL; |
| |
| /* Check if the old cooling action is same as new cooling action */ |
| if (cpufreq_device->cpufreq_state == state) |
| return 0; |
| |
| mutex_lock(&core_isolate_lock); |
| prev_state = cpufreq_device->cpufreq_state; |
| cpufreq_device->cpufreq_state = state; |
| mutex_unlock(&core_isolate_lock); |
| /* If state is the last, isolate the CPU */ |
| if (state == cpufreq_device->max_level) { |
| if (cpu_online(cpu) && |
| (!cpumask_test_and_set_cpu(cpu, |
| &cpus_isolated_by_thermal))) { |
| if (sched_isolate_cpu(cpu)) |
| cpumask_clear_cpu(cpu, |
| &cpus_isolated_by_thermal); |
| } |
| return ret; |
| } else if ((prev_state == cpufreq_device->max_level) |
| && (state < cpufreq_device->max_level)) { |
| if (cpumask_test_and_clear_cpu(cpu, &cpus_pending_online)) { |
| cpu_dev = get_cpu_device(cpu); |
| ret = device_online(cpu_dev); |
| if (ret) |
| pr_err("CPU:%d online error:%d\n", cpu, ret); |
| goto update_frequency; |
| } else if (cpumask_test_and_clear_cpu(cpu, |
| &cpus_isolated_by_thermal)) { |
| sched_unisolate_cpu(cpu); |
| } |
| } |
| update_frequency: |
| clip_freq = cpufreq_device->freq_table[state]; |
| cpufreq_device->clipped_freq = clip_freq; |
| |
| /* Check if the device has a platform mitigation function that |
| * can handle the CPU freq mitigation, if not, notify cpufreq |
| * framework. |
| */ |
| if (cpufreq_device->plat_ops) { |
| if (cpufreq_device->plat_ops->ceil_limit) |
| cpufreq_device->plat_ops->ceil_limit(cpu, |
| clip_freq); |
| } else { |
| if (cpumask_and(&policy_online_cpus, cpu_online_mask, |
| cpufreq_device->policy->related_cpus)) |
| cpufreq_update_policy(cpumask_first( |
| &policy_online_cpus)); |
| } |
| |
| return 0; |
| } |
| |
| /** |
| * cpufreq_get_requested_power() - get the current power |
| * @cdev: &thermal_cooling_device pointer |
| * @tz: a valid thermal zone device pointer |
| * @power: pointer in which to store the resulting power |
| * |
| * Calculate the current power consumption of the cpus in milliwatts |
| * and store it in @power. This function should actually calculate |
| * the requested power, but it's hard to get the frequency that |
| * cpufreq would have assigned if there were no thermal limits. |
| * Instead, we calculate the current power on the assumption that the |
| * immediate future will look like the immediate past. |
| * |
| * We use the current frequency and the average load since this |
| * function was last called. In reality, there could have been |
| * multiple opps since this function was last called and that affects |
| * the load calculation. While it's not perfectly accurate, this |
| * simplification is good enough and works. REVISIT this, as more |
| * complex code may be needed if experiments show that it's not |
| * accurate enough. |
| * |
| * Return: 0 on success, -E* if getting the static power failed. |
| */ |
| static int cpufreq_get_requested_power(struct thermal_cooling_device *cdev, |
| struct thermal_zone_device *tz, |
| u32 *power) |
| { |
| unsigned long freq; |
| int i = 0, cpu, ret; |
| u32 static_power, dynamic_power, total_load = 0; |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| u32 *load_cpu = NULL; |
| |
| cpu = cpumask_any_and(&cpufreq_device->allowed_cpus, cpu_online_mask); |
| |
| /* |
| * All the CPUs are offline, thus the requested power by |
| * the cdev is 0 |
| */ |
| if (cpu >= nr_cpu_ids) { |
| *power = 0; |
| return 0; |
| } |
| |
| freq = cpufreq_quick_get(cpu); |
| |
| if (trace_thermal_power_cpu_get_power_enabled()) { |
| u32 ncpus = cpumask_weight(&cpufreq_device->allowed_cpus); |
| |
| load_cpu = kcalloc(ncpus, sizeof(*load_cpu), GFP_KERNEL); |
| } |
| |
| for_each_cpu(cpu, &cpufreq_device->allowed_cpus) { |
| u32 load; |
| |
| if (cpu_online(cpu)) |
| load = get_load(cpufreq_device, cpu, i); |
| else |
| load = 0; |
| |
| total_load += load; |
| if (load_cpu) |
| load_cpu[i] = load; |
| |
| i++; |
| } |
| |
| cpufreq_device->last_load = total_load; |
| |
| dynamic_power = get_dynamic_power(cpufreq_device, freq); |
| ret = get_static_power(cpufreq_device, tz, freq, &static_power); |
| if (ret) { |
| kfree(load_cpu); |
| return ret; |
| } |
| |
| if (load_cpu) { |
| trace_thermal_power_cpu_get_power( |
| &cpufreq_device->allowed_cpus, |
| freq, load_cpu, i, dynamic_power, static_power); |
| |
| kfree(load_cpu); |
| } |
| |
| *power = static_power + dynamic_power; |
| return 0; |
| } |
| |
| /** |
| * cpufreq_state2power() - convert a cpu cdev state to power consumed |
| * @cdev: &thermal_cooling_device pointer |
| * @tz: a valid thermal zone device pointer |
| * @state: cooling device state to be converted |
| * @power: pointer in which to store the resulting power |
| * |
| * Convert cooling device state @state into power consumption in |
| * milliwatts assuming 100% load. Store the calculated power in |
| * @power. |
| * |
| * Return: 0 on success, -EINVAL if the cooling device state could not |
| * be converted into a frequency or other -E* if there was an error |
| * when calculating the static power. |
| */ |
| static int cpufreq_state2power(struct thermal_cooling_device *cdev, |
| struct thermal_zone_device *tz, |
| unsigned long state, u32 *power) |
| { |
| unsigned int freq, num_cpus; |
| cpumask_t cpumask; |
| u32 static_power, dynamic_power; |
| int ret; |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| |
| cpumask_and(&cpumask, &cpufreq_device->allowed_cpus, cpu_online_mask); |
| num_cpus = cpumask_weight(&cpumask); |
| |
| /* None of our cpus are online, so no power */ |
| if (num_cpus == 0) { |
| *power = 0; |
| return 0; |
| } |
| |
| freq = cpufreq_device->freq_table[state]; |
| if (!freq) |
| return -EINVAL; |
| |
| dynamic_power = cpu_freq_to_power(cpufreq_device, freq) * num_cpus; |
| ret = get_static_power(cpufreq_device, tz, freq, &static_power); |
| if (ret) |
| return ret; |
| |
| *power = static_power + dynamic_power; |
| return 0; |
| } |
| |
| /** |
| * cpufreq_power2state() - convert power to a cooling device state |
| * @cdev: &thermal_cooling_device pointer |
| * @tz: a valid thermal zone device pointer |
| * @power: power in milliwatts to be converted |
| * @state: pointer in which to store the resulting state |
| * |
| * Calculate a cooling device state for the cpus described by @cdev |
| * that would allow them to consume at most @power mW and store it in |
| * @state. Note that this calculation depends on external factors |
| * such as the cpu load or the current static power. Calling this |
| * function with the same power as input can yield different cooling |
| * device states depending on those external factors. |
| * |
| * Return: 0 on success, -ENODEV if no cpus are online or -EINVAL if |
| * the calculated frequency could not be converted to a valid state. |
| * The latter should not happen unless the frequencies available to |
| * cpufreq have changed since the initialization of the cpu cooling |
| * device. |
| */ |
| static int cpufreq_power2state(struct thermal_cooling_device *cdev, |
| struct thermal_zone_device *tz, u32 power, |
| unsigned long *state) |
| { |
| unsigned int cpu, cur_freq, target_freq; |
| int ret; |
| s32 dyn_power; |
| u32 last_load, normalised_power, static_power; |
| struct cpufreq_cooling_device *cpufreq_device = cdev->devdata; |
| |
| cpu = cpumask_any_and(&cpufreq_device->allowed_cpus, cpu_online_mask); |
| |
| /* None of our cpus are online */ |
| if (cpu >= nr_cpu_ids) |
| return -ENODEV; |
| |
| cur_freq = cpufreq_quick_get(cpu); |
| ret = get_static_power(cpufreq_device, tz, cur_freq, &static_power); |
| if (ret) |
| return ret; |
| |
| dyn_power = power - static_power; |
| dyn_power = dyn_power > 0 ? dyn_power : 0; |
| last_load = cpufreq_device->last_load ?: 1; |
| normalised_power = (dyn_power * 100) / last_load; |
| target_freq = cpu_power_to_freq(cpufreq_device, normalised_power); |
| |
| *state = cpufreq_cooling_get_level(cpu, target_freq); |
| if (*state == THERMAL_CSTATE_INVALID) { |
| dev_warn_ratelimited(&cdev->device, |
| "Failed to convert %dKHz for cpu %d into a cdev state\n", |
| target_freq, cpu); |
| return -EINVAL; |
| } |
| |
| trace_thermal_power_cpu_limit(&cpufreq_device->allowed_cpus, |
| target_freq, *state, power); |
| return 0; |
| } |
| |
| /* Bind cpufreq callbacks to thermal cooling device ops */ |
| |
| static struct thermal_cooling_device_ops cpufreq_cooling_ops = { |
| .get_max_state = cpufreq_get_max_state, |
| .get_cur_state = cpufreq_get_cur_state, |
| .set_cur_state = cpufreq_set_cur_state, |
| .set_min_state = cpufreq_set_min_state, |
| .get_min_state = cpufreq_get_min_state, |
| }; |
| |
| static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = { |
| .get_max_state = cpufreq_get_max_state, |
| .get_cur_state = cpufreq_get_cur_state, |
| .set_cur_state = cpufreq_set_cur_state, |
| .get_requested_power = cpufreq_get_requested_power, |
| .state2power = cpufreq_state2power, |
| .power2state = cpufreq_power2state, |
| }; |
| |
| /* Notifier for cpufreq policy change */ |
| static struct notifier_block thermal_cpufreq_notifier_block = { |
| .notifier_call = cpufreq_thermal_notifier, |
| }; |
| |
| static unsigned int find_next_max(struct cpufreq_frequency_table *table, |
| unsigned int prev_max) |
| { |
| struct cpufreq_frequency_table *pos; |
| unsigned int max = 0; |
| |
| cpufreq_for_each_valid_entry(pos, table) { |
| if (pos->frequency > max && pos->frequency < prev_max) |
| max = pos->frequency; |
| } |
| |
| return max; |
| } |
| |
| static void register_cdev(struct work_struct *work) |
| { |
| int ret = 0; |
| |
| ret = cpuhp_setup_state(CPUHP_AP_ONLINE_DYN, |
| "cpu_cooling/no-sched", cpufreq_hp_online, |
| cpufreq_hp_offline); |
| if (ret < 0) |
| pr_err("Error registering for hotpug callback:%d\n", ret); |
| } |
| /** |
| * __cpufreq_cooling_register - helper function to create cpufreq cooling device |
| * @np: a valid struct device_node to the cooling device device tree node |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen. |
| * Normally this should be same as cpufreq policy->related_cpus. |
| * @capacitance: dynamic power coefficient for these cpus |
| * @plat_static_func: function to calculate the static power consumed by these |
| * cpus (optional) |
| * @plat_mitig_func: function that does the mitigation by changing the |
| * frequencies (Optional). By default, cpufreq framweork will |
| * be notified of the new limits. |
| * |
| * This interface function registers the cpufreq cooling device with the name |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq |
| * cooling devices. It also gives the opportunity to link the cooling device |
| * with a device tree node, in order to bind it via the thermal DT code. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| static struct thermal_cooling_device * |
| __cpufreq_cooling_register(struct device_node *np, |
| const struct cpumask *clip_cpus, u32 capacitance, |
| get_static_t plat_static_func, |
| struct cpu_cooling_ops *plat_ops) |
| { |
| struct cpufreq_policy *policy; |
| struct thermal_cooling_device *cool_dev; |
| struct cpufreq_cooling_device *cpufreq_dev; |
| char dev_name[THERMAL_NAME_LENGTH]; |
| struct cpufreq_frequency_table *pos, *table; |
| unsigned int freq, i, num_cpus; |
| int ret; |
| struct thermal_cooling_device_ops *cooling_ops; |
| |
| policy = cpufreq_cpu_get(cpumask_first(clip_cpus)); |
| if (!policy) { |
| pr_debug("%s: CPUFreq policy not found\n", __func__); |
| return ERR_PTR(-EPROBE_DEFER); |
| } |
| |
| table = policy->freq_table; |
| if (!table) { |
| pr_debug("%s: CPUFreq table not found\n", __func__); |
| cool_dev = ERR_PTR(-ENODEV); |
| goto put_policy; |
| } |
| |
| cpufreq_dev = kzalloc(sizeof(*cpufreq_dev), GFP_KERNEL); |
| if (!cpufreq_dev) { |
| cool_dev = ERR_PTR(-ENOMEM); |
| goto put_policy; |
| } |
| |
| cpufreq_dev->policy = policy; |
| num_cpus = cpumask_weight(clip_cpus); |
| cpufreq_dev->time_in_idle = kcalloc(num_cpus, |
| sizeof(*cpufreq_dev->time_in_idle), |
| GFP_KERNEL); |
| if (!cpufreq_dev->time_in_idle) { |
| cool_dev = ERR_PTR(-ENOMEM); |
| goto free_cdev; |
| } |
| |
| cpufreq_dev->time_in_idle_timestamp = |
| kcalloc(num_cpus, sizeof(*cpufreq_dev->time_in_idle_timestamp), |
| GFP_KERNEL); |
| if (!cpufreq_dev->time_in_idle_timestamp) { |
| cool_dev = ERR_PTR(-ENOMEM); |
| goto free_time_in_idle; |
| } |
| |
| /* Find max levels */ |
| cpufreq_for_each_valid_entry(pos, table) |
| cpufreq_dev->max_level++; |
| |
| /* Last level will indicate the core will be isolated. */ |
| cpufreq_dev->max_level++; |
| cpufreq_dev->freq_table = kzalloc(sizeof(*cpufreq_dev->freq_table) * |
| cpufreq_dev->max_level, GFP_KERNEL); |
| if (!cpufreq_dev->freq_table) { |
| cool_dev = ERR_PTR(-ENOMEM); |
| goto free_time_in_idle_timestamp; |
| } |
| |
| /* max_level is an index, not a counter */ |
| cpufreq_dev->max_level--; |
| |
| cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus); |
| |
| if (capacitance) { |
| cpufreq_dev->plat_get_static_power = plat_static_func; |
| |
| ret = build_dyn_power_table(cpufreq_dev, capacitance); |
| if (ret) { |
| cool_dev = ERR_PTR(ret); |
| goto free_table; |
| } |
| |
| cooling_ops = &cpufreq_power_cooling_ops; |
| } else { |
| cooling_ops = &cpufreq_cooling_ops; |
| } |
| |
| cpufreq_dev->plat_ops = plat_ops; |
| |
| ret = get_idr(&cpufreq_idr, &cpufreq_dev->id); |
| if (ret) { |
| cool_dev = ERR_PTR(ret); |
| goto free_power_table; |
| } |
| |
| /* Fill freq-table in descending order of frequencies */ |
| for (i = 0, freq = -1; i < cpufreq_dev->max_level; i++) { |
| freq = find_next_max(table, freq); |
| cpufreq_dev->freq_table[i] = freq; |
| |
| /* Warn for duplicate entries */ |
| if (!freq) |
| pr_warn("%s: table has duplicate entries\n", __func__); |
| else |
| pr_debug("%s: freq:%u KHz\n", __func__, freq); |
| } |
| |
| snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", |
| cpufreq_dev->id); |
| |
| cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev, |
| cooling_ops); |
| if (IS_ERR(cool_dev)) |
| goto remove_idr; |
| |
| cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0]; |
| cpufreq_dev->floor_freq = |
| cpufreq_dev->freq_table[cpufreq_dev->max_level]; |
| cpufreq_dev->cpufreq_floor_state = cpufreq_dev->max_level; |
| cpufreq_dev->cool_dev = cool_dev; |
| |
| mutex_lock(&cooling_cpufreq_lock); |
| |
| mutex_lock(&cooling_list_lock); |
| list_add(&cpufreq_dev->node, &cpufreq_dev_list); |
| mutex_unlock(&cooling_list_lock); |
| |
| /* Register the notifier for first cpufreq cooling device */ |
| if (!cpufreq_dev_count++ && !cpufreq_dev->plat_ops) |
| cpufreq_register_notifier(&thermal_cpufreq_notifier_block, |
| CPUFREQ_POLICY_NOTIFIER); |
| if (!cpuhp_registered) { |
| cpuhp_registered = 1; |
| register_pm_notifier(&cpufreq_cooling_pm_nb); |
| cpumask_clear(&cpus_pending_online); |
| cpumask_clear(&cpus_isolated_by_thermal); |
| INIT_WORK(&cpuhp_register_work, register_cdev); |
| queue_work(system_wq, &cpuhp_register_work); |
| } |
| mutex_unlock(&cooling_cpufreq_lock); |
| |
| goto put_policy; |
| |
| remove_idr: |
| release_idr(&cpufreq_idr, cpufreq_dev->id); |
| free_power_table: |
| kfree(cpufreq_dev->dyn_power_table); |
| free_table: |
| kfree(cpufreq_dev->freq_table); |
| free_time_in_idle_timestamp: |
| kfree(cpufreq_dev->time_in_idle_timestamp); |
| free_time_in_idle: |
| kfree(cpufreq_dev->time_in_idle); |
| free_cdev: |
| kfree(cpufreq_dev); |
| put_policy: |
| cpufreq_cpu_put(policy); |
| |
| return cool_dev; |
| } |
| |
| /** |
| * cpufreq_cooling_register - function to create cpufreq cooling device. |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen. |
| * |
| * This interface function registers the cpufreq cooling device with the name |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq |
| * cooling devices. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| cpufreq_cooling_register(const struct cpumask *clip_cpus) |
| { |
| return __cpufreq_cooling_register(NULL, clip_cpus, 0, NULL, NULL); |
| } |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_register); |
| |
| /** |
| * of_cpufreq_cooling_register - function to create cpufreq cooling device. |
| * @np: a valid struct device_node to the cooling device device tree node |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen. |
| * |
| * This interface function registers the cpufreq cooling device with the name |
| * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq |
| * cooling devices. Using this API, the cpufreq cooling device will be |
| * linked to the device tree node provided. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| of_cpufreq_cooling_register(struct device_node *np, |
| const struct cpumask *clip_cpus) |
| { |
| if (!np) |
| return ERR_PTR(-EINVAL); |
| |
| return __cpufreq_cooling_register(np, clip_cpus, 0, NULL, NULL); |
| } |
| EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); |
| |
| /** |
| * cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen |
| * @capacitance: dynamic power coefficient for these cpus |
| * @plat_static_func: function to calculate the static power consumed by these |
| * cpus (optional) |
| * |
| * This interface function registers the cpufreq cooling device with |
| * the name "thermal-cpufreq-%x". This api can support multiple |
| * instances of cpufreq cooling devices. Using this function, the |
| * cooling device will implement the power extensions by using a |
| * simple cpu power model. The cpus must have registered their OPPs |
| * using the OPP library. |
| * |
| * An optional @plat_static_func may be provided to calculate the |
| * static power consumed by these cpus. If the platform's static |
| * power consumption is unknown or negligible, make it NULL. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| cpufreq_power_cooling_register(const struct cpumask *clip_cpus, u32 capacitance, |
| get_static_t plat_static_func) |
| { |
| return __cpufreq_cooling_register(NULL, clip_cpus, capacitance, |
| plat_static_func, NULL); |
| } |
| EXPORT_SYMBOL(cpufreq_power_cooling_register); |
| |
| /** |
| * cpufreq_platform_cooling_register() - create cpufreq cooling device with |
| * additional platform specific mitigation function. |
| * |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen |
| * @plat_ops: the platform mitigation functions that will be called insted of |
| * cpufreq, if provided. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| cpufreq_platform_cooling_register(const struct cpumask *clip_cpus, |
| struct cpu_cooling_ops *plat_ops) |
| { |
| struct device_node *cpu_node; |
| |
| cpu_node = of_cpu_device_node_get(cpumask_first(clip_cpus)); |
| return __cpufreq_cooling_register(cpu_node, clip_cpus, 0, NULL, |
| plat_ops); |
| } |
| EXPORT_SYMBOL(cpufreq_platform_cooling_register); |
| |
| /** |
| * of_cpufreq_power_cooling_register() - create cpufreq cooling device with power extensions |
| * @np: a valid struct device_node to the cooling device device tree node |
| * @clip_cpus: cpumask of cpus where the frequency constraints will happen |
| * @capacitance: dynamic power coefficient for these cpus |
| * @plat_static_func: function to calculate the static power consumed by these |
| * cpus (optional) |
| * |
| * This interface function registers the cpufreq cooling device with |
| * the name "thermal-cpufreq-%x". This api can support multiple |
| * instances of cpufreq cooling devices. Using this API, the cpufreq |
| * cooling device will be linked to the device tree node provided. |
| * Using this function, the cooling device will implement the power |
| * extensions by using a simple cpu power model. The cpus must have |
| * registered their OPPs using the OPP library. |
| * |
| * An optional @plat_static_func may be provided to calculate the |
| * static power consumed by these cpus. If the platform's static |
| * power consumption is unknown or negligible, make it NULL. |
| * |
| * Return: a valid struct thermal_cooling_device pointer on success, |
| * on failure, it returns a corresponding ERR_PTR(). |
| */ |
| struct thermal_cooling_device * |
| of_cpufreq_power_cooling_register(struct device_node *np, |
| const struct cpumask *clip_cpus, |
| u32 capacitance, |
| get_static_t plat_static_func) |
| { |
| if (!np) |
| return ERR_PTR(-EINVAL); |
| |
| return __cpufreq_cooling_register(np, clip_cpus, capacitance, |
| plat_static_func, NULL); |
| } |
| EXPORT_SYMBOL(of_cpufreq_power_cooling_register); |
| |
| /** |
| * cpufreq_cooling_unregister - function to remove cpufreq cooling device. |
| * @cdev: thermal cooling device pointer. |
| * |
| * This interface function unregisters the "thermal-cpufreq-%x" cooling device. |
| */ |
| void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) |
| { |
| struct cpufreq_cooling_device *cpufreq_dev; |
| |
| if (!cdev) |
| return; |
| |
| cpufreq_dev = cdev->devdata; |
| |
| /* Unregister the notifier for the last cpufreq cooling device */ |
| mutex_lock(&cooling_cpufreq_lock); |
| if (!--cpufreq_dev_count) { |
| unregister_pm_notifier(&cpufreq_cooling_pm_nb); |
| if (!cpufreq_dev->plat_ops) |
| cpufreq_unregister_notifier( |
| &thermal_cpufreq_notifier_block, |
| CPUFREQ_POLICY_NOTIFIER); |
| } |
| |
| mutex_lock(&cooling_list_lock); |
| list_del(&cpufreq_dev->node); |
| mutex_unlock(&cooling_list_lock); |
| |
| mutex_unlock(&cooling_cpufreq_lock); |
| |
| thermal_cooling_device_unregister(cpufreq_dev->cool_dev); |
| release_idr(&cpufreq_idr, cpufreq_dev->id); |
| kfree(cpufreq_dev->dyn_power_table); |
| kfree(cpufreq_dev->time_in_idle_timestamp); |
| kfree(cpufreq_dev->time_in_idle); |
| kfree(cpufreq_dev->freq_table); |
| kfree(cpufreq_dev); |
| } |
| EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister); |