4
5menuconfig THERMAL
Zhang Rui63c4ec92008-04-21 16:07:13 +08006 tristate "Generic Thermal sysfs driver"
Zhang Rui203d3d42008-01-17 15:51:08 +08007 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
Len Brown543a9562008-02-07 16:55:08 -050011 Each thermal zone contains its own temperature, trip points,
Zhang Rui203d3d42008-01-17 15:51:08 +080012 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
Zhang Rui63c4ec92008-04-21 16:07:13 +080014 If you want this support, you should say Y or M here.
Rene Herman16d75232008-06-24 19:38:56 +020015
Zhang Rui72e19892012-11-15 09:16:20 +080016if THERMAL
17
Rene Herman16d75232008-06-24 19:38:56 +020018config THERMAL_HWMON
Jean Delvareab924022011-07-28 13:48:40 -070019 bool
Eduardo Valentin0dd88792013-07-03 15:14:28 -040020 prompt "Expose thermal sensors as hwmon device"
Rene Herman16d75232008-06-24 19:38:56 +020021 depends on HWMON=y || HWMON=THERMAL
Jean Delvareab924022011-07-28 13:48:40 -070022 default y
Eduardo Valentin0dd88792013-07-03 15:14:28 -040023 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
Vincenzo Frascino6a92c362012-03-21 12:55:03 -070031
Eduardo Valentin4e5e4702013-07-03 15:35:39 -040032config THERMAL_OF
33 bool
34 prompt "APIs to parse thermal data out of device tree"
35 depends on OF
36 default y
37 help
38 This options provides helpers to add the support to
39 read and parse thermal data definitions out of the
40 device tree blob.
41
42 Say 'Y' here if you need to build thermal infrastructure
43 based on device tree.
44
Durgadoss Ra56757a2012-09-21 14:32:24 +053045choice
46 prompt "Default Thermal governor"
Durgadoss Ra56757a2012-09-21 14:32:24 +053047 default THERMAL_DEFAULT_GOV_STEP_WISE
48 help
49 This option sets which thermal governor shall be loaded at
50 startup. If in doubt, select 'step_wise'.
51
52config THERMAL_DEFAULT_GOV_STEP_WISE
53 bool "step_wise"
Zhang Rui9d185d02013-02-08 20:33:42 +080054 select THERMAL_GOV_STEP_WISE
Durgadoss Ra56757a2012-09-21 14:32:24 +053055 help
56 Use the step_wise governor as default. This throttles the
57 devices one step at a time.
58
59config THERMAL_DEFAULT_GOV_FAIR_SHARE
60 bool "fair_share"
Zhang Rui9d185d02013-02-08 20:33:42 +080061 select THERMAL_GOV_FAIR_SHARE
Durgadoss Ra56757a2012-09-21 14:32:24 +053062 help
63 Use the fair_share governor as default. This throttles the
64 devices based on their 'contribution' to a zone. The
65 contribution should be provided through platform data.
66
67config THERMAL_DEFAULT_GOV_USER_SPACE
68 bool "user_space"
Zhang Rui9d185d02013-02-08 20:33:42 +080069 select THERMAL_GOV_USER_SPACE
Durgadoss Ra56757a2012-09-21 14:32:24 +053070 help
71 Select this if you want to let the user space manage the
Regid Ichiraece238f2013-09-09 00:58:53 +030072 platform thermals.
Zhang Rui72e19892012-11-15 09:16:20 +080073
Durgadoss Ra56757a2012-09-21 14:32:24 +053074endchoice
Zhang Rui72e19892012-11-15 09:16:20 +080075
Zhang Rui9d185d02013-02-08 20:33:42 +080076config THERMAL_GOV_FAIR_SHARE
Zhang Rui72e19892012-11-15 09:16:20 +080077 bool "Fair-share thermal governor"
78 help
79 Enable this to manage platform thermals using fair-share governor.
80
Zhang Rui9d185d02013-02-08 20:33:42 +080081config THERMAL_GOV_STEP_WISE
Zhang Rui72e19892012-11-15 09:16:20 +080082 bool "Step_wise thermal governor"
83 help
84 Enable this to manage platform thermals using a simple linear
Luka Perkova8227942013-09-27 20:20:33 +020085 governor.
Zhang Rui72e19892012-11-15 09:16:20 +080086
Zhang Rui9d185d02013-02-08 20:33:42 +080087config THERMAL_GOV_USER_SPACE
Zhang Rui72e19892012-11-15 09:16:20 +080088 bool "User_space thermal governor"
89 help
90 Enable this to let the user space manage the platform thermals.
91
92config CPU_THERMAL
Zhang Ruibbf7fc82013-03-26 23:57:01 +080093 bool "generic cpu cooling support"
Zhang Rui72e19892012-11-15 09:16:20 +080094 depends on CPU_FREQ
Zhang Rui72e19892012-11-15 09:16:20 +080095 help
96 This implements the generic cpu cooling mechanism through frequency
Eduardo Valentinf7188b32013-04-17 17:12:10 +000097 reduction. An ACPI version of this already exists
98 (drivers/acpi/processor_thermal.c).
Zhang Rui72e19892012-11-15 09:16:20 +080099 This will be useful for platforms using the generic thermal interface
100 and not the ACPI interface.
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000101
Zhang Rui72e19892012-11-15 09:16:20 +0800102 If you want this support, you should say Y here.
103
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +0000104config THERMAL_EMULATION
105 bool "Thermal emulation mode support"
106 help
107 Enable this option to make a emul_temp sysfs node in thermal zone
108 directory to support temperature emulation. With emulation sysfs node,
109 user can manually input temperature and test the different trip
110 threshold behaviour for simulation purpose.
111
Eduardo Valentin88372952013-03-26 21:38:34 +0000112 WARNING: Be careful while enabling this option on production systems,
113 because userland can easily disable the thermal policy by simply
114 flooding this sysfs node with low temperature values.
115
Shawn Guoca3de462013-06-24 14:30:44 +0800116config IMX_THERMAL
117 tristate "Temperature sensor driver for Freescale i.MX SoCs"
118 depends on CPU_THERMAL
119 depends on MFD_SYSCON
120 depends on OF
121 help
122 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
123 It supports one critical trip point and one passive trip point. The
124 cpufreq is used as the cooling device to throttle CPUs when the
125 passive trip is crossed.
126
Zhang Rui72e19892012-11-15 09:16:20 +0800127config SPEAR_THERMAL
128 bool "SPEAr thermal sensor driver"
129 depends on PLAT_SPEAR
130 depends on OF
131 help
132 Enable this to plug the SPEAr thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200133 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800134
135config RCAR_THERMAL
136 tristate "Renesas R-Car thermal driver"
137 depends on ARCH_SHMOBILE
138 help
139 Enable this to plug the R-Car thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200140 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800141
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000142config KIRKWOOD_THERMAL
143 tristate "Temperature sensor on Marvell Kirkwood SoCs"
144 depends on ARCH_KIRKWOOD
145 depends on OF
146 help
147 Support for the Kirkwood thermal sensor driver into the Linux thermal
148 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
149
Andrew Lunn74ffa642013-02-06 06:35:26 +0000150config DOVE_THERMAL
151 tristate "Temperature sensor on Marvell Dove SoCs"
152 depends on ARCH_DOVE
153 depends on OF
154 help
155 Support for the Dove thermal sensor driver in the Linux thermal
156 framework.
157
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800158config DB8500_THERMAL
159 bool "DB8500 thermal management"
160 depends on ARCH_U8500
161 default y
162 help
163 Adds DB8500 thermal management implementation according to the thermal
164 management framework. A thermal zone with several trip points will be
165 created. Cooling devices can be bound to the trip points to cool this
166 thermal zone if trip points reached.
167
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000168config ARMADA_THERMAL
169 tristate "Armada 370/XP thermal management"
170 depends on ARCH_MVEBU
171 depends on OF
172 help
173 Enable this option if you want to have support for thermal management
174 controller present in Armada 370 and Armada XP SoC.
175
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800176config DB8500_CPUFREQ_COOLING
177 tristate "DB8500 cpufreq cooling"
178 depends on ARCH_U8500
179 depends on CPU_THERMAL
180 default y
181 help
182 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
183 bound to thermal zone trip points. When a trip point reached, the
184 bound cpufreq cooling device turns active to set CPU frequency low to
185 cool down the CPU.
Zhang Rui72e19892012-11-15 09:16:20 +0800186
Jacob Pand6d71ee2013-01-21 04:37:57 -0800187config INTEL_POWERCLAMP
188 tristate "Intel PowerClamp idle injection driver"
189 depends on THERMAL
190 depends on X86
191 depends on CPU_SUP_INTEL
192 help
193 Enable this to enable Intel PowerClamp idle injection driver. This
194 enforce idle time which results in more package C-state residency. The
195 user interface is exposed via generic thermal framework.
196
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000197config X86_PKG_TEMP_THERMAL
198 tristate "X86 package temperature thermal driver"
Randy Dunlapb3ba0202013-06-17 12:27:17 -0700199 depends on X86_THERMAL_VECTOR
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000200 select THERMAL_GOV_USER_SPACE
201 default m
202 help
203 Enable this to register CPU digital sensor for package temperature as
204 thermal zone. Each package will have its own thermal zone. There are
205 two trip points which can be set by user to get notifications via thermal
206 notification methods.
207
Eduardo Valentineb982002013-05-15 15:46:00 +0000208menu "Texas Instruments thermal drivers"
209source "drivers/thermal/ti-soc-thermal/Kconfig"
210endmenu
Zhang Ruif157f592013-06-18 06:31:26 +0800211
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530212menu "Samsung thermal drivers"
213depends on PLAT_SAMSUNG
214source "drivers/thermal/samsung/Kconfig"
215endmenu
216
Zhang Rui72e19892012-11-15 09:16:20 +0800217endif