blob: d59cc7829bec1b223a8e3b577741624d9cc4ee6a [file] [log] [blame]
Guenter Roeck4af33f12011-04-18 09:53:54 -07001Kernel driver max16064
2======================
3
4Supported chips:
5 * Maxim MAX16064
6 Prefix: 'max16064'
7 Addresses scanned: -
8 Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX16064.pdf
9
Guenter Roecke3333e52013-02-20 20:58:42 -080010Author: Guenter Roeck <linux@roeck-us.net>
Guenter Roeck4af33f12011-04-18 09:53:54 -070011
12
13Description
14-----------
15
16This driver supports hardware montoring for Maxim MAX16064 Quad Power-Supply
17Controller with Active-Voltage Output Control and PMBus Interface.
18
19The driver is a client driver to the core PMBus driver.
20Please see Documentation/hwmon/pmbus for details on PMBus client drivers.
21
22
23Usage Notes
24-----------
25
26This driver does not auto-detect devices. You will have to instantiate the
27devices explicitly. Please see Documentation/i2c/instantiating-devices for
28details.
29
30
31Platform data support
32---------------------
33
34The driver supports standard PMBus driver platform data.
35
36
37Sysfs entries
38-------------
39
40The following attributes are supported. Limits are read-write; all other
41attributes are read-only.
42
43in[1-4]_label "vout[1-4]"
44in[1-4]_input Measured voltage. From READ_VOUT register.
Masanari Iida40e47122012-03-04 23:16:11 +090045in[1-4]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
Guenter Roeck4af33f12011-04-18 09:53:54 -070046in[1-4]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
Masanari Iida40e47122012-03-04 23:16:11 +090047in[1-4]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
Guenter Roeck4af33f12011-04-18 09:53:54 -070048in[1-4]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
49in[1-4]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
50in[1-4]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
51in[1-4]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
52in[1-4]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
Guenter Roeck8ebed852011-07-09 13:10:19 -070053in[1-4]_highest Historical maximum voltage.
54in[1-4]_reset_history Write any value to reset history.
Guenter Roeck4af33f12011-04-18 09:53:54 -070055
56temp1_input Measured temperature. From READ_TEMPERATURE_1 register.
57temp1_max Maximum temperature. From OT_WARN_LIMIT register.
58temp1_crit Critical high temperature. From OT_FAULT_LIMIT register.
59temp1_max_alarm Chip temperature high alarm. Set by comparing
60 READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING
61 status is set.
62temp1_crit_alarm Chip temperature critical high alarm. Set by comparing
63 READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT
64 status is set.
Guenter Roeck8ebed852011-07-09 13:10:19 -070065temp1_highest Historical maximum temperature.