blob: ba96596910fd99b0ede9e263b9d352ec68c07cd9 [file] [log] [blame]
Linus Torvalds1da177e2005-04-16 15:20:36 -07001~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2MOTOROLA MICROPROCESSOR & MEMORY TECHNOLOGY GROUP
3M68000 Hi-Performance Microprocessor Division
4M68060 Software Package
5Production Release P1.00 -- October 10, 1994
6
Jan Engelhardt96de0e22007-10-19 23:21:04 +02007M68060 Software Package Copyright © 1993, 1994 Motorola Inc. All rights reserved.
Linus Torvalds1da177e2005-04-16 15:20:36 -07008
9THE SOFTWARE is provided on an "AS IS" basis and without warranty.
10To the maximum extent permitted by applicable law,
11MOTOROLA DISCLAIMS ALL WARRANTIES WHETHER EXPRESS OR IMPLIED,
12INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE
13and any warranty against infringement with regard to the SOFTWARE
14(INCLUDING ANY MODIFIED VERSIONS THEREOF) and any accompanying written materials.
15
16To the maximum extent permitted by applicable law,
17IN NO EVENT SHALL MOTOROLA BE LIABLE FOR ANY DAMAGES WHATSOEVER
18(INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS,
19BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR OTHER PECUNIARY LOSS)
20ARISING OF THE USE OR INABILITY TO USE THE SOFTWARE.
21Motorola assumes no responsibility for the maintenance and support of the SOFTWARE.
22
23You are hereby granted a copyright license to use, modify, and distribute the SOFTWARE
24so long as this entire notice is retained without alteration in any modified and/or
25redistributed versions, and that such modified versions are clearly identified as such.
26No licenses are granted by implication, estoppel or otherwise under any patents
27or trademarks of Motorola, Inc.
28~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
29
30CHANGES SINCE LAST RELEASE:
31---------------------------
32
331) "movep" emulation where data was being read from memory
34was reading the intermediate bytes. Emulation now only
35reads the required bytes.
36
372) "flogn", "flog2", and "flog10" of "1" was setting the
38Inexact FPSR bit. Emulation now does not set Inexact for
39this case.
40
413) For an opclass three FP instruction where the effective addressing
42mode was pre-decrement or post-increment and the address register
43was A0 or A1, the address register was not being updated as a result
44of the operation. This has been corrected.
45
464) Beta B.2 version had the following erratum:
47
48 Scenario:
49 ---------
50 If {i,d}mem_{read,write}_{byte,word,long}() returns
51 a failing value to the 68060SP, the package ignores
52 this return value and continues with program execution
53 as if it never received a failing value.
54
55 Effect:
56 -------
57 For example, if a user executed "fsin.x ADDR,fp0" where
58 ADDR should cause a "segmentation violation", the memory read
59 requested by the package should return a failing value
60 to the package. Since the package currently ignores this
61 return value, the user program will continue to the
62 next instruction, and the result created in fp0 will be
63 undefined.
64
65 Fix:
66 ----
67 This has been fixed in the current release.
68
69 Notes:
70 ------
71 Upon receiving a non-zero (failing) return value from
72 a {i,d}mem_{read,write}_{byte,word,long}() "call-out",
73 the package creates a 16-byte access error stack frame
74 from the current exception stack frame and exits
75 through the "call-out" _real_access(). This is the process
76 as described in the MC68060 User's Manual.
77
78 For instruction read access errors, the info stacked is:
79 SR = SR at time of exception
80 PC = PC of instruction being emulated
81 VOFF = $4008 (stack frame format type)
82 ADDRESS = PC of instruction being emulated
83 FSLW = FAULT STATUS LONGWORD
84
85 The valid FSLW bits are:
86 bit 27 = 1 (misaligned bit)
87 bit 24 = 1 (read)
88 bit 23 = 0 (write)
89 bit 22:21 = 10 (SIZE = word)
90 bit 20:19 = 00 (TT)
91 bit 18:16 = x10 (TM; x = 1 for supervisor mode)
92 bit 15 = 1 (IO)
93 bit 0 = 1 (Software Emulation Error)
94
95 all other bits are EQUAL TO ZERO and can be set by the _real_access()
96 "call-out" stub by the user as appropriate. The MC68060 User's Manual
97 stated that ONLY "bit 0" would be set. The 060SP attempts to set a few
98 other bits.
99
100 For data read/write access errors, the info stacked is:
101 SR = SR at time of exception
102 PC = PC of instruction being emulated
103 VOFF = $4008 (stack frame format type)
104 ADDRESS = Address of source or destination operand
105 FSLW = FAULT STATUS LONGWORD
106
107 The valid FSLW bits are:
108 bit 27 = 0 (misaligned bit)
109 bit 24 = x (read; 1 if read, 0 if write)
110 bit 23 = x (write; 1 if write, 0 if read)
111 bit 22:21 = xx (SIZE; see MC68060 User's Manual)
112 bit 20:19 = 00 (TT)
113 bit 18:16 = x01 (TM; x = 1 for supervisor mode)
114 bit 15 = 0 (IO)
115 bit 0 = 1 (Software Emulation Error)
116
117 all other bits are EQUAL TO ZERO and can be set by the _real_access()
118 "call-out" stub by the user as appropriate. The MC68060 User's Manual
119 stated that ONLY "bit 0" would be set. The 060SP attempts to set a few
120 other bits.