blob: a91adb26ea7bb2eb6afda1bc93b90bf599f1567d [file] [log] [blame]
Linus Torvalds1da177e2005-04-16 15:20:36 -07001CHANGES
2
3- 0.3 - Created based off of scanner & INSTALL from the original touchscreen
Masanari Iida1f8ee462012-02-13 22:42:58 +09004 driver on freecode (http://freecode.com/projects/3mtouchscreendriver)
Linus Torvalds1da177e2005-04-16 15:20:36 -07005- Amended for linux-2.4.18, then 2.4.19
6
7- 0.5 - Complete rewrite using Linux Input in 2.6.3
8 Unfortunately no calibration support at this time
9
10- 1.4 - Multiple changes to support the EXII 5000UC and house cleaning
11 Changed reset from standard USB dev reset to vendor reset
12 Changed data sent to host from compensated to raw coordinates
13 Eliminated vendor/product module params
Matt LaPlante53cb4722006-10-03 22:55:17 +020014 Performed multiple successful tests with an EXII-5010UC
Linus Torvalds1da177e2005-04-16 15:20:36 -070015
16SUPPORTED HARDWARE:
17
18 All controllers have the Vendor: 0x0596 & Product: 0x0001
19
20
21 Controller Description Part Number
22 ------------------------------------------------------
23
24 USB Capacitive - Pearl Case 14-205 (Discontinued)
25 USB Capacitive - Black Case 14-124 (Discontinued)
26 USB Capacitive - No Case 14-206 (Discontinued)
27
28 USB Capacitive - Pearl Case EXII-5010UC
29 USB Capacitive - Black Case EXII-5030UC
30 USB Capacitive - No Case EXII-5050UC
31
32DRIVER NOTES:
33
34Installation is simple, you only need to add Linux Input, Linux USB, and the
35driver to the kernel. The driver can also be optionally built as a module.
36
37This driver appears to be one of possible 2 Linux USB Input Touchscreen
38drivers. Although 3M produces a binary only driver available for
39download, I persist in updating this driver since I would like to use the
40touchscreen for embedded apps using QTEmbedded, DirectFB, etc. So I feel the
Matt LaPlante2fe0ae72006-10-03 22:50:39 +020041logical choice is to use Linux Input.
Linus Torvalds1da177e2005-04-16 15:20:36 -070042
43Currently there is no way to calibrate the device via this driver. Even if
44the device could be calibrated, the driver pulls to raw coordinate data from
45the controller. This means calibration must be performed within the
46userspace.
47
48The controller screen resolution is now 0 to 16384 for both X and Y reporting
49the raw touch data. This is the same for the old and new capacitive USB
50controllers.
51
52Perhaps at some point an abstract function will be placed into evdev so
53generic functions like calibrations, resets, and vendor information can be
54requested from the userspace (And the drivers would handle the vendor specific
55tasks).
56
Linus Torvalds1da177e2005-04-16 15:20:36 -070057TODO:
58
59Implement a control urb again to handle requests to and from the device
60such as calibration, etc once/if it becomes available.
61
Matt LaPlantefff92892006-10-03 22:47:42 +020062DISCLAIMER:
Linus Torvalds1da177e2005-04-16 15:20:36 -070063
64I am not a MicroTouch/3M employee, nor have I ever been. 3M does not support
65this driver! If you want touch drivers only supported within X, please go to:
66
Justin P. Mattock0ea6e612010-07-23 20:51:24 -070067http://www.3m.com/3MTouchSystems/
Linus Torvalds1da177e2005-04-16 15:20:36 -070068
69THANKS:
70
71A huge thank you to 3M Touch Systems for the EXII-5010UC controllers for
72testing!