blob: 0ddd3a4120306331864c8678a5a83f1c95cd3465 [file] [log] [blame]
Guenter Roeck2669d9f2011-04-18 09:51:04 -07001Kernel driver max8688
2=====================
3
4Supported chips:
5 * Maxim MAX8688
6 Prefix: 'max8688'
7 Addresses scanned: -
8 Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX8688.pdf
9
10Author: Guenter Roeck <guenter.roeck@ericsson.com>
11
12
13Description
14-----------
15
16This driver supports hardware montoring for Maxim MAX8688 Digital Power-Supply
17Controller/Monitor with PMBus Interface.
18
19The driver is a client driver to the core PMBus driver. Please see
20Documentation/hwmon/pmbus for details on PMBus client drivers.
21
22
23Usage Notes
24-----------
25
26This driver does not auto-detect devices. You will have to instantiate the
27devices explicitly. Please see Documentation/i2c/instantiating-devices for
28details.
29
30
31Platform data support
32---------------------
33
34The driver supports standard PMBus driver platform data.
35
36
37Sysfs entries
38-------------
39
40The following attributes are supported. Limits are read-write; all other
41attributes are read-only.
42
43in1_label "vout1"
44in1_input Measured voltage. From READ_VOUT register.
45in1_min Minumum Voltage. From VOUT_UV_WARN_LIMIT register.
46in1_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
47in1_lcrit Critical minumum Voltage. VOUT_UV_FAULT_LIMIT register.
48in1_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register.
49in1_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
50in1_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
51in1_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status.
52in1_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status.
53
54curr1_label "iout1"
55curr1_input Measured current. From READ_IOUT register.
56curr1_max Maximum current. From IOUT_OC_WARN_LIMIT register.
57curr1_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register.
58curr1_max_alarm Current high alarm. From IOUT_OC_WARN_LIMIT register.
59curr1_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.
60
61temp1_input Measured temperature. From READ_TEMPERATURE_1 register.
62temp1_max Maximum temperature. From OT_WARN_LIMIT register.
63temp1_crit Critical high temperature. From OT_FAULT_LIMIT register.
64temp1_max_alarm Chip temperature high alarm. Set by comparing
65 READ_TEMPERATURE_1 with OT_WARN_LIMIT if TEMP_OT_WARNING
66 status is set.
67temp1_crit_alarm Chip temperature critical high alarm. Set by comparing
68 READ_TEMPERATURE_1 with OT_FAULT_LIMIT if TEMP_OT_FAULT