blob: be03956bb955afd307ea5c09c99ffe17478c7522 [file] [log] [blame]
JP Abgrall511eca32014-02-12 13:46:45 -08001.\" Copyright (c) 1994, 1996, 1997
2.\" The Regents of the University of California. All rights reserved.
3.\"
4.\" Redistribution and use in source and binary forms, with or without
5.\" modification, are permitted provided that: (1) source code distributions
6.\" retain the above copyright notice and this paragraph in its entirety, (2)
7.\" distributions including binary code include the above copyright notice and
8.\" this paragraph in its entirety in the documentation or other materials
9.\" provided with the distribution, and (3) all advertising materials mentioning
10.\" features or use of this software display the following acknowledgement:
11.\" ``This product includes software developed by the University of California,
12.\" Lawrence Berkeley Laboratory and its contributors.'' Neither the name of
13.\" the University nor the names of its contributors may be used to endorse
14.\" or promote products derived from this software without specific prior
15.\" written permission.
16.\" THIS SOFTWARE IS PROVIDED ``AS IS'' AND WITHOUT ANY EXPRESS OR IMPLIED
17.\" WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF
18.\" MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
19.\"
Haibo Huang165065a2018-07-23 17:26:52 -070020.TH PCAP_CAN_SET_RFMON 3PCAP "31 July 2016"
JP Abgrall511eca32014-02-12 13:46:45 -080021.SH NAME
22pcap_can_set_rfmon \- check whether monitor mode can be set for a
23not-yet-activated capture handle
24.SH SYNOPSIS
25.nf
26.ft B
27#include <pcap/pcap.h>
28.LP
29.ft B
30int pcap_can_set_rfmon(pcap_t *p);
31.ft
32.fi
33.SH DESCRIPTION
Haibo Huangee759ce2021-01-05 21:34:29 -080034.BR pcap_can_set_rfmon ()
JP Abgrall511eca32014-02-12 13:46:45 -080035checks whether monitor mode could be set on a capture handle when
36the handle is activated.
37.SH RETURN VALUE
Haibo Huangee759ce2021-01-05 21:34:29 -080038.BR pcap_can_set_rfmon ()
39returns
40.B 0
41if monitor mode could not be set,
42.B 1
43if monitor mode could be set, and a negative value on error.
Elliott Hughes965a4b52017-05-15 10:37:39 -070044A negative return value indicates what error condition occurred.
45The possible error values are:
46.TP
JP Abgrall511eca32014-02-12 13:46:45 -080047.B PCAP_ERROR_NO_SUCH_DEVICE
Elliott Hughes965a4b52017-05-15 10:37:39 -070048The capture source specified when the handle was created doesn't
49exist.
50.TP
JP Abgrall511eca32014-02-12 13:46:45 -080051.B PCAP_ERROR_PERM_DENIED
Elliott Hughes965a4b52017-05-15 10:37:39 -070052The process doesn't have permission to check whether monitor mode
53could be supported.
54.TP
JP Abgrall511eca32014-02-12 13:46:45 -080055.B PCAP_ERROR_ACTIVATED
Elliott Hughes965a4b52017-05-15 10:37:39 -070056The capture handle has already been activated.
57.TP
JP Abgrall511eca32014-02-12 13:46:45 -080058.B PCAP_ERROR
Elliott Hughes965a4b52017-05-15 10:37:39 -070059Another error occurred.
Haibo Huangee759ce2021-01-05 21:34:29 -080060.BR pcap_geterr (3PCAP)
JP Abgrall511eca32014-02-12 13:46:45 -080061or
Haibo Huangee759ce2021-01-05 21:34:29 -080062.BR \%pcap_perror (3PCAP)
JP Abgrall511eca32014-02-12 13:46:45 -080063may be called with
64.I p
Elliott Hughes965a4b52017-05-15 10:37:39 -070065as an argument to fetch or display a message describing the error.
66.LP
67Additional error codes may be added in the future; a program should
Haibo Huangee759ce2021-01-05 21:34:29 -080068check for
69.BR 0 ,
70.BR 1 ,
71and negative, return codes, and treat all negative
Elliott Hughes965a4b52017-05-15 10:37:39 -070072return codes as errors.
Haibo Huangee759ce2021-01-05 21:34:29 -080073.BR pcap_statustostr (3PCAP)
Elliott Hughes965a4b52017-05-15 10:37:39 -070074can be called, with a warning or error code as an argument, to fetch a
75message describing the warning or error code.
JP Abgrall511eca32014-02-12 13:46:45 -080076.SH SEE ALSO
Haibo Huangee759ce2021-01-05 21:34:29 -080077.BR pcap (3PCAP),
78.BR pcap_create (3PCAP),
79.BR pcap_activate (3PCAP),
80.BR pcap_set_rfmon (3PCAP)