| // This file was extracted from the TCG Published |
| // Trusted Platform Module Library |
| // Part 3: Commands |
| // Family "2.0" |
| // Level 00 Revision 01.16 |
| // October 30, 2014 |
| |
| #include "InternalRoutines.h" |
| #include "Startup_fp.h" |
| // |
| // |
| // Error Returns Meaning |
| // |
| // TPM_RC_LOCALITY a Startup(STATE) does not have the same H-CRTM state as the |
| // previous Startup() or the locality of the startup is not 0 pr 3 |
| // TPM_RC_NV_UNINITIALIZED the saved state cannot be recovered and a Startup(CLEAR) is |
| // requried. |
| // TPM_RC_VALUE start up type is not compatible with previous shutdown sequence |
| // |
| TPM_RC |
| TPM2_Startup( |
| Startup_In *in // IN: input parameter list |
| ) |
| { |
| STARTUP_TYPE startup; |
| TPM_RC result; |
| BOOL prevDrtmPreStartup; |
| BOOL prevStartupLoc3; |
| BYTE locality = _plat__LocalityGet(); |
| |
| // In the PC Client specification, only locality 0 and 3 are allowed |
| if(locality != 0 && locality != 3) |
| return TPM_RC_LOCALITY; |
| // Indicate that the locality was 3 unless there was an H-CRTM |
| if(g_DrtmPreStartup) |
| locality = 0; |
| g_StartupLocality3 = (locality == 3); |
| |
| // The command needs NV update. Check if NV is available. |
| // A TPM_RC_NV_UNAVAILABLE or TPM_RC_NV_RATE error may be returned at |
| // this point |
| result = NvIsAvailable(); |
| if(result != TPM_RC_SUCCESS) |
| return result; |
| |
| // Input Validation |
| |
| // Read orderly shutdown states from previous power cycle |
| NvReadReserved(NV_ORDERLY, &g_prevOrderlyState); |
| |
| // See if the orderly state indicates that state was saved |
| if( (g_prevOrderlyState & ~(PRE_STARTUP_FLAG | STARTUP_LOCALITY_3)) |
| == TPM_SU_STATE) |
| { |
| // If so, extrat the saved flags (HACK) |
| prevDrtmPreStartup = (g_prevOrderlyState & PRE_STARTUP_FLAG) != 0; |
| prevStartupLoc3 = (g_prevOrderlyState & STARTUP_LOCALITY_3) != 0; |
| g_prevOrderlyState = TPM_SU_STATE; |
| } |
| else |
| { |
| prevDrtmPreStartup = 0; |
| prevStartupLoc3 = 0; |
| } |
| // if this startup is a TPM Resume, then the H-CRTM states have to match. |
| if(in->startupType == TPM_SU_STATE) |
| { |
| if(g_DrtmPreStartup != prevDrtmPreStartup) |
| return TPM_RC_VALUE + RC_Startup_startupType; |
| if(g_StartupLocality3 != prevStartupLoc3) |
| return TPM_RC_LOCALITY; |
| } |
| |
| // if the previous power cycle was shut down with no StateSave command, or |
| // with StateSave command for CLEAR, or the part of NV used for TPM_SU_STATE |
| // cannot be recovered, then this cycle can not startup up with STATE |
| if(in->startupType == TPM_SU_STATE) |
| { |
| if( g_prevOrderlyState == SHUTDOWN_NONE |
| || g_prevOrderlyState == TPM_SU_CLEAR) |
| return TPM_RC_VALUE + RC_Startup_startupType; |
| |
| if(g_nvOk == FALSE) |
| return TPM_RC_NV_UNINITIALIZED; |
| } |
| |
| // Internal Date Update |
| |
| // Translate the TPM2_ShutDown and TPM2_Startup sequence into the startup |
| // types. Will only be a SU_RESTART if the NV is OK |
| if( in->startupType == TPM_SU_CLEAR |
| && g_prevOrderlyState == TPM_SU_STATE |
| && g_nvOk == TRUE) |
| { |
| startup = SU_RESTART; |
| // Read state reset data |
| NvReadReserved(NV_STATE_RESET, &gr); |
| } |
| // In this check, we don't need to look at g_nvOk because that was checked |
| // above |
| else if(in->startupType == TPM_SU_STATE && g_prevOrderlyState == TPM_SU_STATE) |
| { |
| // Read state clear and state reset data |
| NvReadReserved(NV_STATE_CLEAR, &gc); |
| NvReadReserved(NV_STATE_RESET, &gr); |
| startup = SU_RESUME; |
| } |
| else |
| { |
| startup = SU_RESET; |
| } |
| |
| // Read persistent data from NV |
| NvReadPersistent(); |
| |
| // Crypto Startup |
| CryptUtilStartup(startup); |
| |
| // Read the platform unique value that is used as VENDOR_PERMANENT auth value |
| g_platformUniqueDetails.t.size = (UINT16)_plat__GetUnique(1, |
| sizeof(g_platformUniqueDetails.t.buffer), |
| g_platformUniqueDetails.t.buffer); |
| |
| // Start up subsystems |
| // Start counters and timers |
| TimeStartup(startup); |
| |
| // Start dictionary attack subsystem |
| DAStartup(startup); |
| |
| // Enable hierarchies |
| HierarchyStartup(startup); |
| |
| // Restore/Initialize PCR |
| PCRStartup(startup, locality); |
| |
| // Restore/Initialize command audit information |
| CommandAuditStartup(startup); |
| |
| // Object context variables |
| if(startup == SU_RESET) |
| { |
| // Reset object context ID to 0 |
| gr.objectContextID = 0; |
| // Reset clearCount to 0 |
| gr.clearCount= 0; |
| } |
| |
| // Initialize session table |
| SessionStartup(startup); |
| |
| // Initialize index/evict data. This function clear read/write locks |
| // in NV index |
| NvEntityStartup(startup); |
| |
| // Initialize the orderly shut down flag for this cycle to SHUTDOWN_NONE. |
| gp.orderlyState = SHUTDOWN_NONE; |
| NvWriteReserved(NV_ORDERLY, &gp.orderlyState); |
| |
| // Update TPM internal states if command succeeded. |
| // Record a TPM2_Startup command has been received. |
| TPMRegisterStartup(); |
| |
| // The H-CRTM state no longer matters |
| g_DrtmPreStartup = FALSE; |
| |
| return TPM_RC_SUCCESS; |
| |
| } |