blob: 5ba470ccb1c7ce37957d1798a2d4d60da5a9c054 [file] [log] [blame]
// This file was extracted from the TCG Published
// Trusted Platform Module Library
// Part 3: Commands
// Family "2.0"
// Level 00 Revision 01.16
// October 30, 2014
#include "InternalRoutines.h"
#include "ReadClock_fp.h"
TPM_RC
TPM2_ReadClock(
ReadClock_Out *out // OUT: output parameter list
)
{
// Command Output
out->currentTime.time = g_time;
TimeFillInfo(&out->currentTime.clockInfo);
#ifndef EMBEDDED_MODE
{
UINT64 start_time = _plat__ClockTimeFromStart();
// When running on a simulator, some tests fail, because two commands
// invoked back to back happen to run within the same millisecond, but
// the test expects time readings to be different. Modifying the tests
// is more involved, let's just wait a couple of milliseconds here to
// avoid those tests' false negatives.
while ((_plat__ClockTimeFromStart() - start_time) < 2)
;
}
#endif
return TPM_RC_SUCCESS;
}