blob: ef5587fe2c69d05fdf1934eb93a80788e4b87cf5 [file] [log] [blame]
Zhang Rui203d3d42008-01-17 15:51:08 +08001#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
Zhang Rui63c4ec92008-04-21 16:07:13 +08006 tristate "Generic Thermal sysfs driver"
Zhang Rui203d3d42008-01-17 15:51:08 +08007 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
Len Brown543a9562008-02-07 16:55:08 -050011 Each thermal zone contains its own temperature, trip points,
Zhang Rui203d3d42008-01-17 15:51:08 +080012 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
Zhang Rui63c4ec92008-04-21 16:07:13 +080014 If you want this support, you should say Y or M here.
Rene Herman16d75232008-06-24 19:38:56 +020015
Zhang Rui72e19892012-11-15 09:16:20 +080016if THERMAL
17
Rene Herman16d75232008-06-24 19:38:56 +020018config THERMAL_HWMON
Jean Delvareab924022011-07-28 13:48:40 -070019 bool
Eduardo Valentin0dd88792013-07-03 15:14:28 -040020 prompt "Expose thermal sensors as hwmon device"
Rene Herman16d75232008-06-24 19:38:56 +020021 depends on HWMON=y || HWMON=THERMAL
Jean Delvareab924022011-07-28 13:48:40 -070022 default y
Eduardo Valentin0dd88792013-07-03 15:14:28 -040023 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
Vincenzo Frascino6a92c362012-03-21 12:55:03 -070031
Eduardo Valentin4e5e4702013-07-03 15:35:39 -040032config THERMAL_OF
33 bool
34 prompt "APIs to parse thermal data out of device tree"
35 depends on OF
36 default y
37 help
38 This options provides helpers to add the support to
39 read and parse thermal data definitions out of the
40 device tree blob.
41
42 Say 'Y' here if you need to build thermal infrastructure
43 based on device tree.
44
Durgadoss Ra56757a2012-09-21 14:32:24 +053045choice
46 prompt "Default Thermal governor"
Durgadoss Ra56757a2012-09-21 14:32:24 +053047 default THERMAL_DEFAULT_GOV_STEP_WISE
48 help
49 This option sets which thermal governor shall be loaded at
50 startup. If in doubt, select 'step_wise'.
51
52config THERMAL_DEFAULT_GOV_STEP_WISE
53 bool "step_wise"
Zhang Rui9d185d02013-02-08 20:33:42 +080054 select THERMAL_GOV_STEP_WISE
Durgadoss Ra56757a2012-09-21 14:32:24 +053055 help
56 Use the step_wise governor as default. This throttles the
57 devices one step at a time.
58
59config THERMAL_DEFAULT_GOV_FAIR_SHARE
60 bool "fair_share"
Zhang Rui9d185d02013-02-08 20:33:42 +080061 select THERMAL_GOV_FAIR_SHARE
Durgadoss Ra56757a2012-09-21 14:32:24 +053062 help
63 Use the fair_share governor as default. This throttles the
64 devices based on their 'contribution' to a zone. The
65 contribution should be provided through platform data.
66
67config THERMAL_DEFAULT_GOV_USER_SPACE
68 bool "user_space"
Zhang Rui9d185d02013-02-08 20:33:42 +080069 select THERMAL_GOV_USER_SPACE
Durgadoss Ra56757a2012-09-21 14:32:24 +053070 help
71 Select this if you want to let the user space manage the
Regid Ichiraece238f2013-09-09 00:58:53 +030072 platform thermals.
Zhang Rui72e19892012-11-15 09:16:20 +080073
Durgadoss Ra56757a2012-09-21 14:32:24 +053074endchoice
Zhang Rui72e19892012-11-15 09:16:20 +080075
Zhang Rui9d185d02013-02-08 20:33:42 +080076config THERMAL_GOV_FAIR_SHARE
Zhang Rui72e19892012-11-15 09:16:20 +080077 bool "Fair-share thermal governor"
78 help
79 Enable this to manage platform thermals using fair-share governor.
80
Zhang Rui9d185d02013-02-08 20:33:42 +080081config THERMAL_GOV_STEP_WISE
Zhang Rui72e19892012-11-15 09:16:20 +080082 bool "Step_wise thermal governor"
83 help
84 Enable this to manage platform thermals using a simple linear
Luka Perkova8227942013-09-27 20:20:33 +020085 governor.
Zhang Rui72e19892012-11-15 09:16:20 +080086
Zhang Rui9d185d02013-02-08 20:33:42 +080087config THERMAL_GOV_USER_SPACE
Zhang Rui72e19892012-11-15 09:16:20 +080088 bool "User_space thermal governor"
89 help
90 Enable this to let the user space manage the platform thermals.
91
92config CPU_THERMAL
Zhang Ruibbf7fc82013-03-26 23:57:01 +080093 bool "generic cpu cooling support"
Zhang Rui72e19892012-11-15 09:16:20 +080094 depends on CPU_FREQ
Eduardo Valentin39d99cf2013-09-12 19:26:45 -040095 depends on THERMAL_OF
Zhang Rui72e19892012-11-15 09:16:20 +080096 help
97 This implements the generic cpu cooling mechanism through frequency
Eduardo Valentinf7188b32013-04-17 17:12:10 +000098 reduction. An ACPI version of this already exists
99 (drivers/acpi/processor_thermal.c).
Zhang Rui72e19892012-11-15 09:16:20 +0800100 This will be useful for platforms using the generic thermal interface
101 and not the ACPI interface.
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000102
Zhang Rui72e19892012-11-15 09:16:20 +0800103 If you want this support, you should say Y here.
104
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +0000105config THERMAL_EMULATION
106 bool "Thermal emulation mode support"
107 help
108 Enable this option to make a emul_temp sysfs node in thermal zone
109 directory to support temperature emulation. With emulation sysfs node,
110 user can manually input temperature and test the different trip
111 threshold behaviour for simulation purpose.
112
Eduardo Valentin88372952013-03-26 21:38:34 +0000113 WARNING: Be careful while enabling this option on production systems,
114 because userland can easily disable the thermal policy by simply
115 flooding this sysfs node with low temperature values.
116
Shawn Guoca3de462013-06-24 14:30:44 +0800117config IMX_THERMAL
118 tristate "Temperature sensor driver for Freescale i.MX SoCs"
119 depends on CPU_THERMAL
120 depends on MFD_SYSCON
121 depends on OF
122 help
123 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
124 It supports one critical trip point and one passive trip point. The
125 cpufreq is used as the cooling device to throttle CPUs when the
126 passive trip is crossed.
127
Zhang Rui72e19892012-11-15 09:16:20 +0800128config SPEAR_THERMAL
129 bool "SPEAr thermal sensor driver"
130 depends on PLAT_SPEAR
131 depends on OF
132 help
133 Enable this to plug the SPEAr thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200134 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800135
136config RCAR_THERMAL
137 tristate "Renesas R-Car thermal driver"
Laurent Pinchartbeeb5a12013-11-27 02:18:34 +0100138 depends on ARCH_SHMOBILE || COMPILE_TEST
Richard Weinbergerd1c8b042014-01-27 09:40:58 +0100139 depends on HAS_IOMEM
Zhang Rui72e19892012-11-15 09:16:20 +0800140 help
141 Enable this to plug the R-Car thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200142 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800143
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000144config KIRKWOOD_THERMAL
145 tristate "Temperature sensor on Marvell Kirkwood SoCs"
Andrew Lunn575be652014-08-30 18:46:08 +0200146 depends on MACH_KIRKWOOD
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000147 depends on OF
148 help
149 Support for the Kirkwood thermal sensor driver into the Linux thermal
150 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
151
Andrew Lunn74ffa642013-02-06 06:35:26 +0000152config DOVE_THERMAL
153 tristate "Temperature sensor on Marvell Dove SoCs"
Riku Voipiob3dee392014-05-31 14:50:26 +0300154 depends on ARCH_DOVE || MACH_DOVE
Andrew Lunn74ffa642013-02-06 06:35:26 +0000155 depends on OF
156 help
157 Support for the Dove thermal sensor driver in the Linux thermal
158 framework.
159
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800160config DB8500_THERMAL
161 bool "DB8500 thermal management"
162 depends on ARCH_U8500
163 default y
164 help
165 Adds DB8500 thermal management implementation according to the thermal
166 management framework. A thermal zone with several trip points will be
167 created. Cooling devices can be bound to the trip points to cool this
168 thermal zone if trip points reached.
169
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000170config ARMADA_THERMAL
171 tristate "Armada 370/XP thermal management"
172 depends on ARCH_MVEBU
173 depends on OF
174 help
175 Enable this option if you want to have support for thermal management
176 controller present in Armada 370 and Armada XP SoC.
177
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800178config DB8500_CPUFREQ_COOLING
179 tristate "DB8500 cpufreq cooling"
180 depends on ARCH_U8500
181 depends on CPU_THERMAL
182 default y
183 help
184 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
185 bound to thermal zone trip points. When a trip point reached, the
186 bound cpufreq cooling device turns active to set CPU frequency low to
187 cool down the CPU.
Zhang Rui72e19892012-11-15 09:16:20 +0800188
Jacob Pand6d71ee2013-01-21 04:37:57 -0800189config INTEL_POWERCLAMP
190 tristate "Intel PowerClamp idle injection driver"
191 depends on THERMAL
192 depends on X86
193 depends on CPU_SUP_INTEL
194 help
195 Enable this to enable Intel PowerClamp idle injection driver. This
196 enforce idle time which results in more package C-state residency. The
197 user interface is exposed via generic thermal framework.
198
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000199config X86_PKG_TEMP_THERMAL
200 tristate "X86 package temperature thermal driver"
Randy Dunlapb3ba0202013-06-17 12:27:17 -0700201 depends on X86_THERMAL_VECTOR
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000202 select THERMAL_GOV_USER_SPACE
203 default m
204 help
205 Enable this to register CPU digital sensor for package temperature as
206 thermal zone. Each package will have its own thermal zone. There are
207 two trip points which can be set by user to get notifications via thermal
208 notification methods.
209
Srinivas Pandruvada925c36b2013-12-30 12:55:06 -0800210config ACPI_INT3403_THERMAL
211 tristate "ACPI INT3403 thermal driver"
212 depends on X86 && ACPI
213 help
Zhang Rui37d6a822014-03-03 23:05:15 +0800214 Newer laptops and tablets that use ACPI may have thermal sensors
215 outside the core CPU/SOC for thermal safety reasons. These
216 temperature sensors are also exposed for the OS to use via the so
217 called INT3403 ACPI object. This driver will, on devices that have
218 such sensors, expose the temperature information from these sensors
219 to userspace via the normal thermal framework. This means that a wide
220 range of applications and GUI widgets can show this information to
221 the user or use this information for making decisions. For example,
222 the Intel Thermal Daemon can use this information to allow the user
223 to select his laptop to run without turning on the fans.
Srinivas Pandruvada925c36b2013-12-30 12:55:06 -0800224
Srinivas Pandruvadabc40b5e2014-04-07 13:57:15 -0700225config INTEL_SOC_DTS_THERMAL
226 tristate "Intel SoCs DTS thermal driver"
227 depends on X86 && IOSF_MBI
228 help
229 Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
230 temperature sensor (DTS). These SoCs have two additional DTSs in
231 addition to DTSs on CPU cores. Each DTS will be registered as a
232 thermal zone. There are two trip points. One of the trip point can
233 be set by user mode programs to get notifications via Linux thermal
234 notification methods.The other trip is a critical trip point, which
235 was set by the driver based on the TJ MAX temperature.
236
Eduardo Valentineb982002013-05-15 15:46:00 +0000237menu "Texas Instruments thermal drivers"
238source "drivers/thermal/ti-soc-thermal/Kconfig"
239endmenu
Zhang Ruif157f592013-06-18 06:31:26 +0800240
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530241menu "Samsung thermal drivers"
Bartlomiej Zolnierkiewicz4de45812013-10-04 14:36:42 +0200242depends on ARCH_EXYNOS
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530243source "drivers/thermal/samsung/Kconfig"
244endmenu
245
Lee Jones60aef7c2014-06-05 16:06:55 +0100246menu "STMicroelectronics thermal drivers"
247depends on ARCH_STI && OF
248source "drivers/thermal/st/Kconfig"
249endmenu
250
Zhang Rui72e19892012-11-15 09:16:20 +0800251endif