blob: 51c9d0a7cd0658b4481db471b91072a2d17ea936 [file] [log] [blame]
Zhang Rui203d3d42008-01-17 15:51:08 +08001#
2# Generic thermal sysfs drivers configuration
3#
4
5menuconfig THERMAL
Zhang Rui63c4ec92008-04-21 16:07:13 +08006 tristate "Generic Thermal sysfs driver"
Zhang Rui203d3d42008-01-17 15:51:08 +08007 help
8 Generic Thermal Sysfs driver offers a generic mechanism for
9 thermal management. Usually it's made up of one or more thermal
10 zone and cooling device.
Len Brown543a9562008-02-07 16:55:08 -050011 Each thermal zone contains its own temperature, trip points,
Zhang Rui203d3d42008-01-17 15:51:08 +080012 cooling devices.
13 All platforms with ACPI thermal support can use this driver.
Zhang Rui63c4ec92008-04-21 16:07:13 +080014 If you want this support, you should say Y or M here.
Rene Herman16d75232008-06-24 19:38:56 +020015
Zhang Rui72e19892012-11-15 09:16:20 +080016if THERMAL
17
Rene Herman16d75232008-06-24 19:38:56 +020018config THERMAL_HWMON
Jean Delvareab924022011-07-28 13:48:40 -070019 bool
Eduardo Valentin0dd88792013-07-03 15:14:28 -040020 prompt "Expose thermal sensors as hwmon device"
Rene Herman16d75232008-06-24 19:38:56 +020021 depends on HWMON=y || HWMON=THERMAL
Jean Delvareab924022011-07-28 13:48:40 -070022 default y
Eduardo Valentin0dd88792013-07-03 15:14:28 -040023 help
24 In case a sensor is registered with the thermal
25 framework, this option will also register it
26 as a hwmon. The sensor will then have the common
27 hwmon sysfs interface.
28
29 Say 'Y' here if you want all thermal sensors to
30 have hwmon sysfs interface too.
Vincenzo Frascino6a92c362012-03-21 12:55:03 -070031
Eduardo Valentin4e5e4702013-07-03 15:35:39 -040032config THERMAL_OF
33 bool
34 prompt "APIs to parse thermal data out of device tree"
35 depends on OF
36 default y
37 help
38 This options provides helpers to add the support to
39 read and parse thermal data definitions out of the
40 device tree blob.
41
42 Say 'Y' here if you need to build thermal infrastructure
43 based on device tree.
44
Punit Agrawal35e94642015-03-03 10:43:03 +000045config THERMAL_WRITABLE_TRIPS
46 bool "Enable writable trip points"
47 help
48 This option allows the system integrator to choose whether
49 trip temperatures can be changed from userspace. The
50 writable trips need to be specified when setting up the
51 thermal zone but the choice here takes precedence.
52
53 Say 'Y' here if you would like to allow userspace tools to
54 change trip temperatures.
55
Durgadoss Ra56757a2012-09-21 14:32:24 +053056choice
57 prompt "Default Thermal governor"
Durgadoss Ra56757a2012-09-21 14:32:24 +053058 default THERMAL_DEFAULT_GOV_STEP_WISE
59 help
60 This option sets which thermal governor shall be loaded at
61 startup. If in doubt, select 'step_wise'.
62
63config THERMAL_DEFAULT_GOV_STEP_WISE
64 bool "step_wise"
Zhang Rui9d185d02013-02-08 20:33:42 +080065 select THERMAL_GOV_STEP_WISE
Durgadoss Ra56757a2012-09-21 14:32:24 +053066 help
67 Use the step_wise governor as default. This throttles the
68 devices one step at a time.
69
70config THERMAL_DEFAULT_GOV_FAIR_SHARE
71 bool "fair_share"
Zhang Rui9d185d02013-02-08 20:33:42 +080072 select THERMAL_GOV_FAIR_SHARE
Durgadoss Ra56757a2012-09-21 14:32:24 +053073 help
74 Use the fair_share governor as default. This throttles the
75 devices based on their 'contribution' to a zone. The
76 contribution should be provided through platform data.
77
78config THERMAL_DEFAULT_GOV_USER_SPACE
79 bool "user_space"
Zhang Rui9d185d02013-02-08 20:33:42 +080080 select THERMAL_GOV_USER_SPACE
Durgadoss Ra56757a2012-09-21 14:32:24 +053081 help
82 Select this if you want to let the user space manage the
Regid Ichiraece238f2013-09-09 00:58:53 +030083 platform thermals.
Zhang Rui72e19892012-11-15 09:16:20 +080084
Javi Merino6b775e82015-03-02 17:17:19 +000085config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
86 bool "power_allocator"
87 select THERMAL_GOV_POWER_ALLOCATOR
88 help
89 Select this if you want to control temperature based on
90 system and device power allocation. This governor can only
91 operate on cooling devices that implement the power API.
92
Durgadoss Ra56757a2012-09-21 14:32:24 +053093endchoice
Zhang Rui72e19892012-11-15 09:16:20 +080094
Zhang Rui9d185d02013-02-08 20:33:42 +080095config THERMAL_GOV_FAIR_SHARE
Zhang Rui72e19892012-11-15 09:16:20 +080096 bool "Fair-share thermal governor"
97 help
98 Enable this to manage platform thermals using fair-share governor.
99
Zhang Rui9d185d02013-02-08 20:33:42 +0800100config THERMAL_GOV_STEP_WISE
Zhang Rui72e19892012-11-15 09:16:20 +0800101 bool "Step_wise thermal governor"
102 help
103 Enable this to manage platform thermals using a simple linear
Luka Perkova8227942013-09-27 20:20:33 +0200104 governor.
Zhang Rui72e19892012-11-15 09:16:20 +0800105
Peter Feuerere4dbf982014-07-22 17:37:13 +0200106config THERMAL_GOV_BANG_BANG
107 bool "Bang Bang thermal governor"
108 default n
109 help
110 Enable this to manage platform thermals using bang bang governor.
111
112 Say 'Y' here if you want to use two point temperature regulation
113 used for fans without throttling. Some fan drivers depend on this
114 governor to be enabled (e.g. acerhdf).
115
Zhang Rui9d185d02013-02-08 20:33:42 +0800116config THERMAL_GOV_USER_SPACE
Zhang Rui72e19892012-11-15 09:16:20 +0800117 bool "User_space thermal governor"
118 help
119 Enable this to let the user space manage the platform thermals.
120
Ram Chandrasekar6d44a342016-07-07 11:09:52 -0600121config THERMAL_GOV_LOW_LIMITS
122 bool "Low limits mitigation governor"
123 help
124 Enable this to manage platform limits using low limits
125 governor.
126
127 Enable this governor to monitor and trigger floor mitigation.
128 This governor will monitor the limits going below a
129 trip threshold to trigger a floor mitigation.
130
Javi Merino6b775e82015-03-02 17:17:19 +0000131config THERMAL_GOV_POWER_ALLOCATOR
132 bool "Power allocator thermal governor"
Javi Merino6b775e82015-03-02 17:17:19 +0000133 help
134 Enable this to manage platform thermals by dynamically
135 allocating and limiting power to devices.
136
Zhang Rui72e19892012-11-15 09:16:20 +0800137config CPU_THERMAL
Zhang Ruibbf7fc82013-03-26 23:57:01 +0800138 bool "generic cpu cooling support"
Zhang Rui72e19892012-11-15 09:16:20 +0800139 depends on CPU_FREQ
Eduardo Valentin39d99cf2013-09-12 19:26:45 -0400140 depends on THERMAL_OF
Zhang Rui72e19892012-11-15 09:16:20 +0800141 help
142 This implements the generic cpu cooling mechanism through frequency
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000143 reduction. An ACPI version of this already exists
144 (drivers/acpi/processor_thermal.c).
Zhang Rui72e19892012-11-15 09:16:20 +0800145 This will be useful for platforms using the generic thermal interface
146 and not the ACPI interface.
Eduardo Valentinf7188b32013-04-17 17:12:10 +0000147
Zhang Rui72e19892012-11-15 09:16:20 +0800148 If you want this support, you should say Y here.
149
Eduardo Valentinf9df89d2014-01-06 09:04:18 -0400150config CLOCK_THERMAL
151 bool "Generic clock cooling support"
152 depends on COMMON_CLK
153 depends on PM_OPP
154 help
155 This entry implements the generic clock cooling mechanism through
156 frequency clipping. Typically used to cool off co-processors. The
157 device that is configured to use this cooling mechanism will be
158 controlled to reduce clock frequency whenever temperature is high.
159
Ørjan Eidea76caf52015-09-10 18:09:30 +0100160config DEVFREQ_THERMAL
161 bool "Generic device cooling support"
162 depends on PM_DEVFREQ
163 depends on PM_OPP
164 help
165 This implements the generic devfreq cooling mechanism through
166 frequency reduction for devices using devfreq.
167
168 This will throttle the device by limiting the maximum allowed DVFS
169 frequency corresponding to the cooling level.
170
171 In order to use the power extensions of the cooling device,
172 devfreq should use the simple_ondemand governor.
173
Eduardo Valentinf9df89d2014-01-06 09:04:18 -0400174 If you want this support, you should say Y here.
175
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +0000176config THERMAL_EMULATION
177 bool "Thermal emulation mode support"
178 help
179 Enable this option to make a emul_temp sysfs node in thermal zone
180 directory to support temperature emulation. With emulation sysfs node,
181 user can manually input temperature and test the different trip
182 threshold behaviour for simulation purpose.
183
Eduardo Valentin88372952013-03-26 21:38:34 +0000184 WARNING: Be careful while enabling this option on production systems,
185 because userland can easily disable the thermal policy by simply
186 flooding this sysfs node with low temperature values.
187
kongxinwei9a5238a2015-05-20 19:16:37 +0800188config HISI_THERMAL
189 tristate "Hisilicon thermal driver"
Eduardo Valentinf9e2b052015-09-09 20:39:44 -0700190 depends on (ARCH_HISI && CPU_THERMAL && OF) || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900191 depends on HAS_IOMEM
kongxinwei9a5238a2015-05-20 19:16:37 +0800192 help
193 Enable this to plug hisilicon's thermal sensor driver into the Linux
194 thermal framework. cpufreq is used as the cooling device to throttle
195 CPUs when the passive trip is crossed.
196
Shawn Guoca3de462013-06-24 14:30:44 +0800197config IMX_THERMAL
198 tristate "Temperature sensor driver for Freescale i.MX SoCs"
Peter Robinsoneea6a362016-05-25 14:45:50 +0100199 depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
Shawn Guoca3de462013-06-24 14:30:44 +0800200 depends on MFD_SYSCON
201 depends on OF
202 help
203 Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
204 It supports one critical trip point and one passive trip point. The
205 cpufreq is used as the cooling device to throttle CPUs when the
206 passive trip is crossed.
207
Laxman Dewanganec4664b2016-08-23 13:50:27 +0530208config MAX77620_THERMAL
209 tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
210 depends on MFD_MAX77620
211 depends on OF
212 help
213 Support for die junction temperature warning alarm for Maxim
214 Semiconductor PMIC MAX77620 device. Device generates two alarm
215 interrupts when PMIC die temperature cross the threshold of
216 120 degC and 140 degC.
217
Jia Hongtao43528442016-06-30 11:08:38 +0800218config QORIQ_THERMAL
219 tristate "QorIQ Thermal Monitoring Unit"
220 depends on THERMAL_OF
221 depends on HAS_IOMEM
222 help
223 Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
224 It supports one critical trip point and one passive trip point. The
225 cpufreq is used as the cooling device to throttle CPUs when the
226 passive trip is crossed.
227
Zhang Rui72e19892012-11-15 09:16:20 +0800228config SPEAR_THERMAL
Arnd Bergmann4d2f1792016-01-25 17:44:11 +0100229 tristate "SPEAr thermal sensor driver"
Eduardo Valentinaa2937b2015-09-09 20:42:01 -0700230 depends on PLAT_SPEAR || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900231 depends on HAS_IOMEM
Zhang Rui72e19892012-11-15 09:16:20 +0800232 depends on OF
233 help
234 Enable this to plug the SPEAr thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200235 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800236
Caesar Wangcbac8f632014-11-24 12:58:59 +0800237config ROCKCHIP_THERMAL
238 tristate "Rockchip thermal driver"
Eduardo Valentin444f9b02015-09-09 20:43:57 -0700239 depends on ARCH_ROCKCHIP || COMPILE_TEST
Caesar Wangcbac8f632014-11-24 12:58:59 +0800240 depends on RESET_CONTROLLER
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900241 depends on HAS_IOMEM
Caesar Wangcbac8f632014-11-24 12:58:59 +0800242 help
243 Rockchip thermal driver provides support for Temperature sensor
244 ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
245 trip point. Cpufreq is used as the cooling device and will throttle
246 CPUs when the Temperature crosses the passive trip point.
247
Zhang Rui72e19892012-11-15 09:16:20 +0800248config RCAR_THERMAL
249 tristate "Renesas R-Car thermal driver"
Simon Horman8255e4e2016-03-02 11:04:26 +0900250 depends on ARCH_RENESAS || COMPILE_TEST
Richard Weinbergerd1c8b042014-01-27 09:40:58 +0100251 depends on HAS_IOMEM
Zhang Rui72e19892012-11-15 09:16:20 +0800252 help
253 Enable this to plug the R-Car thermal sensor driver into the Linux
Luka Perkova8227942013-09-27 20:20:33 +0200254 thermal framework.
Zhang Rui72e19892012-11-15 09:16:20 +0800255
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000256config KIRKWOOD_THERMAL
257 tristate "Temperature sensor on Marvell Kirkwood SoCs"
Eduardo Valentin9c8aa952015-09-09 20:44:46 -0700258 depends on MACH_KIRKWOOD || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900259 depends on HAS_IOMEM
Nobuhiro Iwamatsu7060aa32013-02-06 06:35:24 +0000260 depends on OF
261 help
262 Support for the Kirkwood thermal sensor driver into the Linux thermal
263 framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
264
Andrew Lunn74ffa642013-02-06 06:35:26 +0000265config DOVE_THERMAL
266 tristate "Temperature sensor on Marvell Dove SoCs"
Eduardo Valentin07fffd52015-09-09 20:45:25 -0700267 depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900268 depends on HAS_IOMEM
Andrew Lunn74ffa642013-02-06 06:35:26 +0000269 depends on OF
270 help
271 Support for the Dove thermal sensor driver in the Linux thermal
272 framework.
273
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800274config DB8500_THERMAL
Arnd Bergmann26716ce2016-01-25 17:44:12 +0100275 tristate "DB8500 thermal management"
276 depends on MFD_DB8500_PRCMU
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800277 default y
278 help
279 Adds DB8500 thermal management implementation according to the thermal
280 management framework. A thermal zone with several trip points will be
281 created. Cooling devices can be bound to the trip points to cool this
282 thermal zone if trip points reached.
283
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000284config ARMADA_THERMAL
285 tristate "Armada 370/XP thermal management"
Eduardo Valentin1b158262015-09-09 20:48:00 -0700286 depends on ARCH_MVEBU || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900287 depends on HAS_IOMEM
Ezequiel Garciafa0d6542013-04-02 01:37:41 +0000288 depends on OF
289 help
290 Enable this option if you want to have support for thermal management
291 controller present in Armada 370 and Armada XP SoC.
292
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800293config DB8500_CPUFREQ_COOLING
294 tristate "DB8500 cpufreq cooling"
Luis de Bethencourt527860f2015-10-14 19:43:29 +0100295 depends on ARCH_U8500 || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900296 depends on HAS_IOMEM
hongbo.zhangaa1acb02012-11-15 18:56:42 +0800297 depends on CPU_THERMAL
298 default y
299 help
300 Adds DB8500 cpufreq cooling devices, and these cooling devices can be
301 bound to thermal zone trip points. When a trip point reached, the
302 bound cpufreq cooling device turns active to set CPU frequency low to
303 cool down the CPU.
Zhang Rui72e19892012-11-15 09:16:20 +0800304
Jacob Pand6d71ee2013-01-21 04:37:57 -0800305config INTEL_POWERCLAMP
306 tristate "Intel PowerClamp idle injection driver"
307 depends on THERMAL
308 depends on X86
309 depends on CPU_SUP_INTEL
310 help
311 Enable this to enable Intel PowerClamp idle injection driver. This
312 enforce idle time which results in more package C-state residency. The
313 user interface is exposed via generic thermal framework.
314
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000315config X86_PKG_TEMP_THERMAL
316 tristate "X86 package temperature thermal driver"
Randy Dunlapb3ba0202013-06-17 12:27:17 -0700317 depends on X86_THERMAL_VECTOR
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000318 select THERMAL_GOV_USER_SPACE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700319 select THERMAL_WRITABLE_TRIPS
Srinivas Pandruvadaf1a18a12013-05-17 23:42:02 +0000320 default m
321 help
322 Enable this to register CPU digital sensor for package temperature as
323 thermal zone. Each package will have its own thermal zone. There are
324 two trip points which can be set by user to get notifications via thermal
325 notification methods.
326
Srinivas Pandruvadaee073602015-03-02 13:12:58 -0800327config INTEL_SOC_DTS_IOSF_CORE
328 tristate
Arnd Bergmann3bdcbc642017-07-21 18:16:28 +0200329 depends on X86 && PCI
Srinivas Pandruvadaee073602015-03-02 13:12:58 -0800330 select IOSF_MBI
331 help
332 This is becoming a common feature for Intel SoCs to expose the additional
333 digital temperature sensors (DTSs) using side band interface (IOSF). This
334 implements the common set of helper functions to register, get temperature
335 and get/set thresholds on DTSs.
336
Srinivas Pandruvadabc40b5e2014-04-07 13:57:15 -0700337config INTEL_SOC_DTS_THERMAL
338 tristate "Intel SoCs DTS thermal driver"
Arnd Bergmann3bdcbc642017-07-21 18:16:28 +0200339 depends on X86 && PCI
Srinivas Pandruvada3a2419f2015-03-02 13:12:59 -0800340 select INTEL_SOC_DTS_IOSF_CORE
Srinivas Pandruvada98cadf22015-08-03 04:13:16 -0700341 select THERMAL_WRITABLE_TRIPS
Srinivas Pandruvadabc40b5e2014-04-07 13:57:15 -0700342 help
343 Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
344 temperature sensor (DTS). These SoCs have two additional DTSs in
345 addition to DTSs on CPU cores. Each DTS will be registered as a
346 thermal zone. There are two trip points. One of the trip point can
347 be set by user mode programs to get notifications via Linux thermal
348 notification methods.The other trip is a critical trip point, which
349 was set by the driver based on the TJ MAX temperature.
350
Ong, Boon Leong8c187692015-04-15 10:08:15 +0800351config INTEL_QUARK_DTS_THERMAL
352 tristate "Intel Quark DTS thermal driver"
353 depends on X86_INTEL_QUARK
354 help
355 Enable this to register Intel Quark SoC (e.g. X1000) platform digital
356 temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
357 The DTS will be registered as a thermal zone. There are two trip points:
358 hot & critical. The critical trip point default value is set by
359 underlying BIOS/Firmware.
360
Aaron Lua3c89332016-05-09 15:54:58 +0800361menu "ACPI INT340X thermal drivers"
362source drivers/thermal/int340x_thermal/Kconfig
363endmenu
Jacob Pan52b1c692014-09-03 15:14:23 +0800364
Bin Gaob4743032016-08-29 09:55:04 -0700365config INTEL_BXT_PMIC_THERMAL
366 tristate "Intel Broxton PMIC thermal driver"
367 depends on X86 && INTEL_SOC_PMIC && REGMAP
368 help
369 Select this driver for Intel Broxton PMIC with ADC channels monitoring
370 system temperature measurements and alerts.
371 This driver is used for monitoring the ADC channels of PMIC and handles
372 the alert trip point interrupts and notifies the thermal framework with
373 the trip point and temperature details of the zone.
374
Tushar Daved0a12622015-06-10 13:34:24 -0700375config INTEL_PCH_THERMAL
376 tristate "Intel PCH Thermal Reporting Driver"
377 depends on X86 && PCI
378 help
379 Enable this to support thermal reporting on certain intel PCHs.
380 Thermal reporting device will provide temperature reading,
381 programmable trip points and other information.
382
Sascha Hauera92db1c2015-11-30 12:42:32 +0100383config MTK_THERMAL
384 tristate "Temperature sensor driver for mediatek SoCs"
385 depends on ARCH_MEDIATEK || COMPILE_TEST
Eduardo Valentin74e50532016-03-08 13:32:48 -0800386 depends on HAS_IOMEM
Randy Dunlap62e14f62016-04-19 09:44:23 -0700387 depends on NVMEM || NVMEM=n
Johannes Berga6f48502016-04-14 15:15:20 +0200388 depends on RESET_CONTROLLER
Sascha Hauera92db1c2015-11-30 12:42:32 +0100389 default y
390 help
391 Enable this option if you want to have support for thermal management
392 controller present in Mediatek SoCs
393
Eduardo Valentineb982002013-05-15 15:46:00 +0000394menu "Texas Instruments thermal drivers"
Eduardo Valentinec2feb42015-09-09 21:13:41 -0700395depends on ARCH_HAS_BANDGAP || COMPILE_TEST
Krzysztof Kozlowskibf82c352016-03-04 10:03:59 +0900396depends on HAS_IOMEM
Eduardo Valentineb982002013-05-15 15:46:00 +0000397source "drivers/thermal/ti-soc-thermal/Kconfig"
398endmenu
Zhang Ruif157f592013-06-18 06:31:26 +0800399
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530400menu "Samsung thermal drivers"
Eduardo Valentin2bf42732015-09-09 20:53:35 -0700401depends on ARCH_EXYNOS || COMPILE_TEST
Amit Daniel Kachhapc6821372013-06-24 16:20:22 +0530402source "drivers/thermal/samsung/Kconfig"
403endmenu
404
Lee Jones60aef7c2014-06-05 16:06:55 +0100405menu "STMicroelectronics thermal drivers"
406depends on ARCH_STI && OF
407source "drivers/thermal/st/Kconfig"
408endmenu
409
Marc Gonzalez0b58c082016-04-19 16:21:16 +0200410config TANGO_THERMAL
411 tristate "Tango thermal management"
412 depends on ARCH_TANGO || COMPILE_TEST
413 help
414 Enable the Tango thermal driver, which supports the primitive
415 temperature sensor embedded in Tango chips since the SMP8758.
416 This sensor only generates a 1-bit signal to indicate whether
417 the die temperature exceeds a programmable threshold.
418
Wei Nia4dff942016-03-29 18:29:11 +0800419source "drivers/thermal/tegra/Kconfig"
420
Ivan T. Ivanovc610afa2015-02-05 19:12:56 +0200421config QCOM_SPMI_TEMP_ALARM
422 tristate "Qualcomm SPMI PMIC Temperature Alarm"
Arnd Bergmanne4217462015-11-16 22:43:50 +0100423 depends on OF && SPMI && IIO
Ivan T. Ivanovc610afa2015-02-05 19:12:56 +0200424 select REGMAP_SPMI
425 help
426 This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
427 PMIC devices. It shows up in sysfs as a thermal sensor with multiple
428 trip points. The temperature reported by the thermal sensor reflects the
429 real time die temperature if an ADC is present or an estimate of the
430 temperature based upon the over temperature stage value.
431
David Collins8885f792017-01-26 14:36:34 -0800432config THERMAL_QPNP
433 tristate "Qualcomm Technologies, Inc. QPNP PMIC Temperature Alarm"
434 depends on OF && SPMI
435 help
436 This enables a thermal Sysfs driver for Qualcomm Technologies, Inc.
437 QPNP PMIC devices. It shows up in Sysfs as a thermal zone with
438 multiple trip points. The temperature reported by the thermal zone
439 reflects the real time die temperature if an ADC is present or an
440 estimate of the temperature based upon the over temperature stage
441 value if no ADC is available. If allowed via compile time
442 configuration; enabling the thermal zone device via the mode file
443 results in shifting PMIC over temperature shutdown control from
444 hardware to software.
445
Laxman Dewanganb3aef782016-04-19 12:52:01 +0530446config GENERIC_ADC_THERMAL
447 tristate "Generic ADC based thermal sensor"
448 depends on IIO
449 help
450 This enabled a thermal sysfs driver for the temperature sensor
451 which is connected to the General Purpose ADC. The ADC channel
452 is read via IIO framework and the channel information is provided
453 to this driver. This driver reports the temperature by reading ADC
454 channel and converts it to temperature based on lookup table.
455
Siddartha Mohanadoss45a944b2017-01-23 19:46:10 -0800456config THERMAL_QPNP_ADC_TM
457 tristate "Qualcomm Technologies Inc. Thermal Monitor ADC Driver"
458 depends on THERMAL
459 depends on SPMI
460 help
461 This enables the thermal Sysfs driver for the ADC thermal monitoring
462 device. It shows up in Sysfs as a thermal zone with multiple trip points.
463 Disabling the thermal zone device via the mode file results in disabling
464 the sensor. Also able to set threshold temperature for both hot and cold
465 and update when a threshold is reached.
466
Siddartha Mohanadoss41b4cd92017-02-21 14:34:23 -0800467config THERMAL_TSENS
468 tristate "Qualcomm Technologies Inc. TSENS Temperature driver"
469 depends on THERMAL
470 help
471 This enables the thermal sysfs driver for the TSENS device. It shows
472 up in Sysfs as a thermal zone with multiple trip points. Also able
473 to set threshold temperature for both warm and cool and update
474 thermal userspace client when a threshold is reached. Warm/Cool
475 temperature thresholds can be set independently for each sensor.
476
Rajendra Nayak90660732016-05-05 14:21:39 +0530477menu "Qualcomm thermal drivers"
478depends on (ARCH_QCOM && OF) || COMPILE_TEST
479source "drivers/thermal/qcom/Kconfig"
480endmenu
481
Zhang Rui72e19892012-11-15 09:16:20 +0800482endif