Zhang Rui203d3d42008-01-17 15:51:08 +08001Generic Thermal Sysfs driver How To
Frans Pop38bb0842009-10-26 08:38:59 +01002===================================
Zhang Rui203d3d42008-01-17 15:51:08 +08003
4Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
5
6Updated: 2 January 2008
7
8Copyright (c) 2008 Intel Corporation
9
10
110. Introduction
12
Frans Pop38bb0842009-10-26 08:38:59 +010013The generic thermal sysfs provides a set of interfaces for thermal zone
14devices (sensors) and thermal cooling devices (fan, processor...) to register
15with the thermal management solution and to be a part of it.
Zhang Rui203d3d42008-01-17 15:51:08 +080016
Frans Pop38bb0842009-10-26 08:38:59 +010017This how-to focuses on enabling new thermal zone and cooling devices to
18participate in thermal management.
19This solution is platform independent and any type of thermal zone devices
20and cooling devices should be able to make use of the infrastructure.
Zhang Rui203d3d42008-01-17 15:51:08 +080021
Frans Pop38bb0842009-10-26 08:38:59 +010022The main task of the thermal sysfs driver is to expose thermal zone attributes
23as well as cooling device attributes to the user space.
24An intelligent thermal management application can make decisions based on
25inputs from thermal zone attributes (the current temperature and trip point
26temperature) and throttle appropriate devices.
Zhang Rui203d3d42008-01-17 15:51:08 +080027
28[0-*] denotes any positive number starting from 0
29[1-*] denotes any positive number starting from 1
30
311. thermal sysfs driver interface functions
32
331.1 thermal zone device interface
Zhang Rui514e6d22013-04-24 16:59:22 +0000341.1.1 struct thermal_zone_device *thermal_zone_device_register(char *type,
Durgadoss Rc56f5c02012-07-25 10:10:58 +080035 int trips, int mask, void *devdata,
Zhang Rui514e6d22013-04-24 16:59:22 +000036 struct thermal_zone_device_ops *ops,
37 const struct thermal_zone_params *tzp,
38 int passive_delay, int polling_delay))
Zhang Rui203d3d42008-01-17 15:51:08 +080039
Frans Pop38bb0842009-10-26 08:38:59 +010040 This interface function adds a new thermal zone device (sensor) to
41 /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
42 thermal cooling devices registered at the same time.
Zhang Rui203d3d42008-01-17 15:51:08 +080043
Zhang Rui514e6d22013-04-24 16:59:22 +000044 type: the thermal zone type.
Frans Pop38bb0842009-10-26 08:38:59 +010045 trips: the total number of trip points this thermal zone supports.
Durgadoss Rc56f5c02012-07-25 10:10:58 +080046 mask: Bit string: If 'n'th bit is set, then trip point 'n' is writeable.
Frans Pop38bb0842009-10-26 08:38:59 +010047 devdata: device private data
48 ops: thermal zone device call-backs.
49 .bind: bind the thermal zone device with a thermal cooling device.
50 .unbind: unbind the thermal zone device with a thermal cooling device.
51 .get_temp: get the current temperature of the thermal zone.
Zhang Rui8eaa8d62012-07-25 10:11:00 +080052 .get_mode: get the current mode (enabled/disabled) of the thermal zone.
53 - "enabled" means the kernel thermal management is enabled.
54 - "disabled" will prevent kernel thermal driver action upon trip points
Frans Pop38bb0842009-10-26 08:38:59 +010055 so that user applications can take charge of thermal management.
Zhang Rui8eaa8d62012-07-25 10:11:00 +080056 .set_mode: set the mode (enabled/disabled) of the thermal zone.
Frans Pop38bb0842009-10-26 08:38:59 +010057 .get_trip_type: get the type of certain trip point.
58 .get_trip_temp: get the temperature above which the certain trip point
59 will be fired.
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +000060 .set_emul_temp: set the emulation temperature which helps in debugging
61 different threshold temperature points.
Zhang Rui514e6d22013-04-24 16:59:22 +000062 tzp: thermal zone platform parameters.
63 passive_delay: number of milliseconds to wait between polls when
64 performing passive cooling.
65 polling_delay: number of milliseconds to wait between polls when checking
66 whether trip points have been crossed (0 for interrupt driven systems).
67
Zhang Rui203d3d42008-01-17 15:51:08 +080068
691.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
70
Frans Pop38bb0842009-10-26 08:38:59 +010071 This interface function removes the thermal zone device.
72 It deletes the corresponding entry form /sys/class/thermal folder and
73 unbind all the thermal cooling devices it uses.
Zhang Rui203d3d42008-01-17 15:51:08 +080074
751.2 thermal cooling device interface
761.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
Frans Pop38bb0842009-10-26 08:38:59 +010077 void *devdata, struct thermal_cooling_device_ops *)
Zhang Rui203d3d42008-01-17 15:51:08 +080078
Frans Pop38bb0842009-10-26 08:38:59 +010079 This interface function adds a new thermal cooling device (fan/processor/...)
80 to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
81 to all the thermal zone devices register at the same time.
82 name: the cooling device name.
83 devdata: device private data.
84 ops: thermal cooling devices call-backs.
85 .get_max_state: get the Maximum throttle state of the cooling device.
86 .get_cur_state: get the Current throttle state of the cooling device.
87 .set_cur_state: set the Current throttle state of the cooling device.
Zhang Rui203d3d42008-01-17 15:51:08 +080088
891.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
90
Frans Pop38bb0842009-10-26 08:38:59 +010091 This interface function remove the thermal cooling device.
92 It deletes the corresponding entry form /sys/class/thermal folder and
93 unbind itself from all the thermal zone devices using it.
Zhang Rui203d3d42008-01-17 15:51:08 +080094
951.3 interface for binding a thermal zone device with a thermal cooling device
961.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
Zhang Rui9d998422012-06-26 16:35:57 +080097 int trip, struct thermal_cooling_device *cdev,
Kapileshwar Singh6cd9e9f2015-02-18 16:04:21 +000098 unsigned long upper, unsigned long lower, unsigned int weight);
Zhang Rui203d3d42008-01-17 15:51:08 +080099
Frans Pop38bb0842009-10-26 08:38:59 +0100100 This interface function bind a thermal cooling device to the certain trip
101 point of a thermal zone device.
102 This function is usually called in the thermal zone device .bind callback.
103 tz: the thermal zone device
104 cdev: thermal cooling device
105 trip: indicates which trip point the cooling devices is associated with
106 in this thermal zone.
Zhang Rui9d998422012-06-26 16:35:57 +0800107 upper:the Maximum cooling state for this trip point.
108 THERMAL_NO_LIMIT means no upper limit,
109 and the cooling device can be in max_state.
110 lower:the Minimum cooling state can be used for this trip point.
111 THERMAL_NO_LIMIT means no lower limit,
112 and the cooling device can be in cooling state 0.
Kapileshwar Singh6cd9e9f2015-02-18 16:04:21 +0000113 weight: the influence of this cooling device in this thermal
114 zone. See 1.4.1 below for more information.
Zhang Rui203d3d42008-01-17 15:51:08 +0800115
1161.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
Frans Pop38bb0842009-10-26 08:38:59 +0100117 int trip, struct thermal_cooling_device *cdev);
Zhang Rui203d3d42008-01-17 15:51:08 +0800118
Frans Pop38bb0842009-10-26 08:38:59 +0100119 This interface function unbind a thermal cooling device from the certain
120 trip point of a thermal zone device. This function is usually called in
121 the thermal zone device .unbind callback.
122 tz: the thermal zone device
123 cdev: thermal cooling device
124 trip: indicates which trip point the cooling devices is associated with
125 in this thermal zone.
Zhang Rui203d3d42008-01-17 15:51:08 +0800126
Durgadoss R6ea083b2012-09-18 11:05:06 +05301271.4 Thermal Zone Parameters
1281.4.1 struct thermal_bind_params
129 This structure defines the following parameters that are used to bind
130 a zone with a cooling device for a particular trip point.
131 .cdev: The cooling device pointer
Javi Merinobcdcbbc2015-02-18 16:04:25 +0000132 .weight: The 'influence' of a particular cooling device on this
133 zone. This is relative to the rest of the cooling
134 devices. For example, if all cooling devices have a
135 weight of 1, then they all contribute the same. You can
136 use percentages if you want, but it's not mandatory. A
137 weight of 0 means that this cooling device doesn't
138 contribute to the cooling of this zone unless all cooling
139 devices have a weight of 0. If all weights are 0, then
140 they all contribute the same.
Durgadoss R6ea083b2012-09-18 11:05:06 +0530141 .trip_mask:This is a bit mask that gives the binding relation between
142 this thermal zone and cdev, for a particular trip point.
143 If nth bit is set, then the cdev and thermal zone are bound
144 for trip point n.
Eduardo Valentina8892d832013-07-16 15:26:28 -0400145 .limits: This is an array of cooling state limits. Must have exactly
146 2 * thermal_zone.number_of_trip_points. It is an array consisting
147 of tuples <lower-state upper-state> of state limits. Each trip
148 will be associated with one state limit tuple when binding.
149 A NULL pointer means <THERMAL_NO_LIMITS THERMAL_NO_LIMITS>
150 on all trips. These limits are used when binding a cdev to a
151 trip point.
Durgadoss R6ea083b2012-09-18 11:05:06 +0530152 .match: This call back returns success(0) if the 'tz and cdev' need to
153 be bound, as per platform data.
1541.4.2 struct thermal_zone_params
155 This structure defines the platform level parameters for a thermal zone.
156 This data, for each thermal zone should come from the platform layer.
157 This is an optional feature where some platforms can choose not to
158 provide this data.
159 .governor_name: Name of the thermal governor used for this zone
Eduardo Valentinccba4ff2013-08-15 11:34:17 -0400160 .no_hwmon: a boolean to indicate if the thermal to hwmon sysfs interface
161 is required. when no_hwmon == false, a hwmon sysfs interface
162 will be created. when no_hwmon == true, nothing will be done.
163 In case the thermal_zone_params is NULL, the hwmon interface
164 will be created (for backward compatibility).
Durgadoss R6ea083b2012-09-18 11:05:06 +0530165 .num_tbps: Number of thermal_bind_params entries for this zone
166 .tbp: thermal_bind_params entries
167
Zhang Rui203d3d42008-01-17 15:51:08 +08001682. sysfs attributes structure
169
170RO read only value
171RW read/write value
172
Zhang Ruie9ae7102008-04-22 08:50:09 +0800173Thermal sysfs attributes will be represented under /sys/class/thermal.
174Hwmon sysfs I/F extension is also available under /sys/class/hwmon
175if hwmon is compiled in or built as a module.
Zhang Rui203d3d42008-01-17 15:51:08 +0800176
177Thermal zone device sys I/F, created once it's registered:
Zhang Ruie9ae7102008-04-22 08:50:09 +0800178/sys/class/thermal/thermal_zone[0-*]:
Frans Pop38bb0842009-10-26 08:38:59 +0100179 |---type: Type of the thermal zone
180 |---temp: Current temperature
181 |---mode: Working mode of the thermal zone
Durgadoss R6ea083b2012-09-18 11:05:06 +0530182 |---policy: Thermal governor used for this zone
Frans Pop38bb0842009-10-26 08:38:59 +0100183 |---trip_point_[0-*]_temp: Trip point temperature
184 |---trip_point_[0-*]_type: Trip point type
Durgadoss R27365a62012-07-25 10:10:59 +0800185 |---trip_point_[0-*]_hyst: Hysteresis value for this trip point
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +0000186 |---emul_temp: Emulated temperature set node
Zhang Rui203d3d42008-01-17 15:51:08 +0800187
188Thermal cooling device sys I/F, created once it's registered:
Zhang Ruie9ae7102008-04-22 08:50:09 +0800189/sys/class/thermal/cooling_device[0-*]:
Frans Pop38bb0842009-10-26 08:38:59 +0100190 |---type: Type of the cooling device(processor/fan/...)
191 |---max_state: Maximum cooling state of the cooling device
192 |---cur_state: Current cooling state of the cooling device
Zhang Rui203d3d42008-01-17 15:51:08 +0800193
194
Frans Pop38bb0842009-10-26 08:38:59 +0100195Then next two dynamic attributes are created/removed in pairs. They represent
196the relationship between a thermal zone and its associated cooling device.
197They are created/removed for each successful execution of
198thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
Zhang Rui203d3d42008-01-17 15:51:08 +0800199
Frans Pop38bb0842009-10-26 08:38:59 +0100200/sys/class/thermal/thermal_zone[0-*]:
201 |---cdev[0-*]: [0-*]th cooling device in current thermal zone
202 |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
Javi Merinodb916512015-02-18 16:04:24 +0000203 |---cdev[0-*]_weight: Influence of the cooling device in
204 this thermal zone
Zhang Rui203d3d42008-01-17 15:51:08 +0800205
Zhang Ruie9ae7102008-04-22 08:50:09 +0800206Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
Frans Pop38bb0842009-10-26 08:38:59 +0100207the generic thermal driver also creates a hwmon sysfs I/F for each _type_
208of thermal zone device. E.g. the generic thermal driver registers one hwmon
209class device and build the associated hwmon sysfs I/F for all the registered
210ACPI thermal zones.
211
Zhang Ruie9ae7102008-04-22 08:50:09 +0800212/sys/class/hwmon/hwmon[0-*]:
Frans Pop38bb0842009-10-26 08:38:59 +0100213 |---name: The type of the thermal zone devices
214 |---temp[1-*]_input: The current temperature of thermal zone [1-*]
215 |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
216
Zhang Ruie9ae7102008-04-22 08:50:09 +0800217Please read Documentation/hwmon/sysfs-interface for additional information.
Zhang Rui203d3d42008-01-17 15:51:08 +0800218
219***************************
220* Thermal zone attributes *
221***************************
222
Frans Pop38bb0842009-10-26 08:38:59 +0100223type
224 Strings which represent the thermal zone type.
225 This is given by thermal zone driver as part of registration.
226 E.g: "acpitz" indicates it's an ACPI thermal device.
227 In order to keep it consistent with hwmon sys attribute; this should
228 be a short, lowercase string, not containing spaces nor dashes.
229 RO, Required
Zhang Rui203d3d42008-01-17 15:51:08 +0800230
Frans Pop38bb0842009-10-26 08:38:59 +0100231temp
232 Current temperature as reported by thermal zone (sensor).
233 Unit: millidegree Celsius
234 RO, Required
Zhang Rui203d3d42008-01-17 15:51:08 +0800235
Frans Pop38bb0842009-10-26 08:38:59 +0100236mode
Zhang Rui8eaa8d62012-07-25 10:11:00 +0800237 One of the predefined values in [enabled, disabled].
Frans Pop38bb0842009-10-26 08:38:59 +0100238 This file gives information about the algorithm that is currently
239 managing the thermal zone. It can be either default kernel based
240 algorithm or user space application.
Zhang Rui8eaa8d62012-07-25 10:11:00 +0800241 enabled = enable Kernel Thermal management.
242 disabled = Preventing kernel thermal zone driver actions upon
243 trip points so that user application can take full
244 charge of the thermal management.
Frans Pop38bb0842009-10-26 08:38:59 +0100245 RW, Optional
Zhang Rui203d3d42008-01-17 15:51:08 +0800246
Durgadoss R6ea083b2012-09-18 11:05:06 +0530247policy
248 One of the various thermal governors used for a particular zone.
249 RW, Required
250
Frans Pop38bb0842009-10-26 08:38:59 +0100251trip_point_[0-*]_temp
252 The temperature above which trip point will be fired.
253 Unit: millidegree Celsius
254 RO, Optional
Zhang Rui203d3d42008-01-17 15:51:08 +0800255
Frans Pop38bb0842009-10-26 08:38:59 +0100256trip_point_[0-*]_type
257 Strings which indicate the type of the trip point.
258 E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
259 thermal zone.
260 RO, Optional
Zhang Rui203d3d42008-01-17 15:51:08 +0800261
Durgadoss R27365a62012-07-25 10:10:59 +0800262trip_point_[0-*]_hyst
263 The hysteresis value for a trip point, represented as an integer
264 Unit: Celsius
265 RW, Optional
266
Frans Pop38bb0842009-10-26 08:38:59 +0100267cdev[0-*]
268 Sysfs link to the thermal cooling device node where the sys I/F
269 for cooling device throttling control represents.
270 RO, Optional
Zhang Rui203d3d42008-01-17 15:51:08 +0800271
Frans Pop38bb0842009-10-26 08:38:59 +0100272cdev[0-*]_trip_point
273 The trip point with which cdev[0-*] is associated in this thermal
274 zone; -1 means the cooling device is not associated with any trip
275 point.
276 RO, Optional
Zhang Rui203d3d42008-01-17 15:51:08 +0800277
Javi Merinodb916512015-02-18 16:04:24 +0000278cdev[0-*]_weight
279 The influence of cdev[0-*] in this thermal zone. This value
280 is relative to the rest of cooling devices in the thermal
281 zone. For example, if a cooling device has a weight double
282 than that of other, it's twice as effective in cooling the
283 thermal zone.
284 RW, Optional
285
Frans Pop29226ed2009-10-26 08:39:00 +0100286passive
287 Attribute is only present for zones in which the passive cooling
288 policy is not supported by native thermal driver. Default is zero
289 and can be set to a temperature (in millidegrees) to enable a
290 passive trip point for the zone. Activation is done by polling with
291 an interval of 1 second.
292 Unit: millidegrees Celsius
Frans Pop3d8e3ad2009-10-26 08:39:02 +0100293 Valid values: 0 (disabled) or greater than 1000
Frans Pop29226ed2009-10-26 08:39:00 +0100294 RW, Optional
295
Amit Daniel Kachhape6e238c2013-02-04 00:30:15 +0000296emul_temp
297 Interface to set the emulated temperature method in thermal zone
298 (sensor). After setting this temperature, the thermal zone may pass
299 this temperature to platform emulation function if registered or
300 cache it locally. This is useful in debugging different temperature
301 threshold and its associated cooling action. This is write only node
302 and writing 0 on this node should disable emulation.
303 Unit: millidegree Celsius
304 WO, Optional
305
Eduardo Valentin88372952013-03-26 21:38:34 +0000306 WARNING: Be careful while enabling this option on production systems,
307 because userland can easily disable the thermal policy by simply
308 flooding this sysfs node with low temperature values.
309
Frans Pop38bb0842009-10-26 08:38:59 +0100310*****************************
311* Cooling device attributes *
312*****************************
Zhang Rui203d3d42008-01-17 15:51:08 +0800313
Frans Pop38bb0842009-10-26 08:38:59 +0100314type
315 String which represents the type of device, e.g:
316 - for generic ACPI: should be "Fan", "Processor" or "LCD"
317 - for memory controller device on intel_menlow platform:
318 should be "Memory controller".
319 RO, Required
Zhang Rui203d3d42008-01-17 15:51:08 +0800320
Frans Pop38bb0842009-10-26 08:38:59 +0100321max_state
322 The maximum permissible cooling state of this cooling device.
323 RO, Required
Zhang Rui203d3d42008-01-17 15:51:08 +0800324
Frans Pop38bb0842009-10-26 08:38:59 +0100325cur_state
326 The current cooling state of this cooling device.
327 The value can any integer numbers between 0 and max_state:
328 - cur_state == 0 means no cooling
329 - cur_state == max_state means the maximum cooling.
330 RW, Required
Zhang Rui203d3d42008-01-17 15:51:08 +0800331
3323. A simple implementation
333
Frans Pop38bb0842009-10-26 08:38:59 +0100334ACPI thermal zone may support multiple trip points like critical, hot,
335passive, active. If an ACPI thermal zone supports critical, passive,
336active[0] and active[1] at the same time, it may register itself as a
337thermal_zone_device (thermal_zone1) with 4 trip points in all.
338It has one processor and one fan, which are both registered as
Javi Merinodb916512015-02-18 16:04:24 +0000339thermal_cooling_device. Both are considered to have the same
340effectiveness in cooling the thermal zone.
Frans Pop38bb0842009-10-26 08:38:59 +0100341
342If the processor is listed in _PSL method, and the fan is listed in _AL0
343method, the sys I/F structure will be built like this:
Zhang Rui203d3d42008-01-17 15:51:08 +0800344
345/sys/class/thermal:
346
347|thermal_zone1:
Frans Pop38bb0842009-10-26 08:38:59 +0100348 |---type: acpitz
349 |---temp: 37000
Zhang Rui8eaa8d62012-07-25 10:11:00 +0800350 |---mode: enabled
Durgadoss R6ea083b2012-09-18 11:05:06 +0530351 |---policy: step_wise
Frans Pop38bb0842009-10-26 08:38:59 +0100352 |---trip_point_0_temp: 100000
353 |---trip_point_0_type: critical
354 |---trip_point_1_temp: 80000
355 |---trip_point_1_type: passive
356 |---trip_point_2_temp: 70000
357 |---trip_point_2_type: active0
358 |---trip_point_3_temp: 60000
359 |---trip_point_3_type: active1
360 |---cdev0: --->/sys/class/thermal/cooling_device0
361 |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
Javi Merinodb916512015-02-18 16:04:24 +0000362 |---cdev0_weight: 1024
Frans Pop38bb0842009-10-26 08:38:59 +0100363 |---cdev1: --->/sys/class/thermal/cooling_device3
364 |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
Javi Merinodb916512015-02-18 16:04:24 +0000365 |---cdev1_weight: 1024
Zhang Rui203d3d42008-01-17 15:51:08 +0800366
367|cooling_device0:
Frans Pop38bb0842009-10-26 08:38:59 +0100368 |---type: Processor
369 |---max_state: 8
370 |---cur_state: 0
Zhang Rui203d3d42008-01-17 15:51:08 +0800371
372|cooling_device3:
Frans Pop38bb0842009-10-26 08:38:59 +0100373 |---type: Fan
374 |---max_state: 2
375 |---cur_state: 0
Zhang Ruie9ae7102008-04-22 08:50:09 +0800376
377/sys/class/hwmon:
378
379|hwmon0:
Frans Pop38bb0842009-10-26 08:38:59 +0100380 |---name: acpitz
381 |---temp1_input: 37000
382 |---temp1_crit: 100000
R.Durgadoss4cb18722010-10-27 03:33:29 +0530383
3844. Event Notification
385
386The framework includes a simple notification mechanism, in the form of a
387netlink event. Netlink socket initialization is done during the _init_
388of the framework. Drivers which intend to use the notification mechanism
Jean Delvare2d58d7e2011-11-04 10:31:04 +0100389just need to call thermal_generate_netlink_event() with two arguments viz
Eduardo Valentin8ab3e6a2013-01-02 15:29:39 +0000390(originator, event). The originator is a pointer to struct thermal_zone_device
391from where the event has been originated. An integer which represents the
392thermal zone device will be used in the message to identify the zone. The
R.Durgadoss4cb18722010-10-27 03:33:29 +0530393event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
394THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
395crosses any of the configured thresholds.
Durgadoss R6ea083b2012-09-18 11:05:06 +0530396
3975. Export Symbol APIs:
398
3995.1: get_tz_trend:
400This function returns the trend of a thermal zone, i.e the rate of change
401of temperature of the thermal zone. Ideally, the thermal sensor drivers
402are supposed to implement the callback. If they don't, the thermal
403framework calculated the trend by comparing the previous and the current
404temperature values.
405
4065.2:get_thermal_instance:
407This function returns the thermal_instance corresponding to a given
408{thermal_zone, cooling_device, trip_point} combination. Returns NULL
409if such an instance does not exist.
410
Eduardo Valentin7b73c992013-04-23 21:48:14 +00004115.3:thermal_notify_framework:
Durgadoss R6ea083b2012-09-18 11:05:06 +0530412This function handles the trip events from sensor drivers. It starts
413throttling the cooling devices according to the policy configured.
414For CRITICAL and HOT trip points, this notifies the respective drivers,
415and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
416The throttling policy is based on the configured platform data; if no
417platform data is provided, this uses the step_wise throttling policy.
418
4195.4:thermal_cdev_update:
420This function serves as an arbitrator to set the state of a cooling
421device. It sets the cooling device to the deepest cooling state if
422possible.